Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 3300/20-11-01-01-00-02
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3300/20-11-01-01-00-02

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/20-11-01-01-00-02
  • Estimated shipping dimensions:
    5.1×32×20.5cm
  • Weight:
    1.02 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Measurement channels:
    2 independent axial-position channels
  • Position scale:
    0.5-0-0.5 mm
  • Selected transducer sensitivity:
    200 mV/mil (approximately 8 V/mm)
  • Signal input impedance:
    10 kΩ
  • Nominal consumption:
    1.5 W
  • Signal-conditioning accuracy at +25 °C:
    ±0.33% full-scale typical; ±1% maximum
  • Recorder output selections:
    4–20 mA; 1–5 V DC; 0 to -10 V DC
  • Current recorder load:
    0–600 Ω
  • Voltage recorder minimum load:
    10 kΩ
  • Buffered output impedance:
    100 Ω
  • Alarm setpoint adjustment:
    0–100% full-scale; normal and counter directions
  • Alarm repeatability:
    Within 0.39% full-scale
  • Alarm delay selections:
    0.1, 1, 3 or 6 s
  • Relay construction:
    Epoxy sealed
  • Safety barrier configuration:
    Internal
  • Operating temperature:
    0 to +65 °C

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3300/20-11-01-01-00-02 combines a narrow metric axial-position scale with internally barrier-equipped signal interfaces, bringing field-circuit compatibility into the same channel review as gap and alarm setup.
  • Displays each shaft-position channel on its own bargraph.
  • Provides individual recorder outputs proportional to the configured range.
  • Allows normal thrust direction to be selected per channel.
  • Includes internal safety barriers in the selected assembly.

The internal-barrier selection must be assessed with the connected transducers and field wiring. It does not by itself establish approval for a hazardous-area installation; the complete assembly and installation conditions still apply.

Important Notice: Retain the internal-barrier signal interface when selecting a replacement assembly. Do not substitute an unbarriered rear interface merely because the front monitor range matches.

Bently Nevada 3300/20-11-01-01-00-02 Manuals & Downloads
Bently Nevada 3300/20-11-01-01-00-02 Official Technical Reference Excerpt (PDF)Bently Nevada 3300/20-11-01-01-00-02 Installation & Commissioning Guide (PDF)

The technical excerpt covers monitor characteristics and configuration choices. The installation guide addresses two-probe alignment, field connections, direction checks and alarm acceptance.

Thrust collar position
Measure axial displacement of the collar relative to bearing clearance.
Dual-channel thrust protection
Compare two probes observing the same collar or shaft.
Bidirectional axial travel
Apply normal and counter-thrust thresholds to the selected position scale.
Remote position recording
Send individually scaled channel outputs to a compatible receiver.
Check both axial-position channels and their alarm paths before returning Bently Nevada 3300/20-11-01-01-00-02 to service.
1
Identify both probes and the thrust collar they observe.
2
Record the current gap and normal-direction setting for each channel.
3
Check the 0.5-0-0.5 mm scale against the machine travel requirement.
4
Verify the 200 mV/mil input sensitivity and transducer supply.
5
Retain the selected epoxy sealed relay arrangement.
6
Confirm the internal safety barrier connections before reconnecting field wiring.
7
Test normal and counter Alert and Danger thresholds under the maintenance procedure.
8
Restore voting, reset, delay and bypass settings before returning protection to service.

Technical notes

Separate monitor accuracy, recorder-output accuracy, LCD resolution and alarm repeatability when assessing the complete measurement. The recorder-output error is additional to the signal-conditioning error.

FAQ View All FAQ

  • Does the internal-barrier option in 3300/20-11-01-01-00-02 allow the four-relay arrangement?
    No. The 3300/20 internal safety barrier option is not available with Quad Relays. This selected configuration uses the compatible epoxy-sealed relay arrangement.
  • Does 3300/20-11-01-01-00-02 include a hazardous-area approval just because it has internal barriers?
    No. Barrier selection and agency approval are separate choices. This complete order code has no agency-approval option selected; evaluate the complete installation requirements independently.
  • What is visible on the center scale of 3300/20-11-01-01-00-02?
    The center scale indicates probe gap. The two separate side bargraphs display the channel measurements, helping distinguish raw gap condition from the axial-position indication.
  • Are the buffered connections and recorder outputs of 3300/20-11-01-01-00-02 the same signal?
    No. Buffered outputs expose the transducer signal; recorder outputs are proportional to the programmed monitor full-scale. Select the connection appropriate to the measurement being checked.
  • Where can both buffered transducer signals be accessed on 3300/20-11-01-01-00-02?
    Each channel has a front-panel coaxial connector and a rear terminal connection. These buffered outputs are short-circuit protected and have 100 Ω output impedance.
  • What does a 5 Hz flashing green OK LED mean on 3300/20-11-01-01-00-02?
    It indicates that error codes are stored in memory. Read the displayed error information rather than interpreting the flashing LED as a steady healthy-channel indication.
  • Can Alert and Danger reset behavior be configured separately on 3300/20-11-01-01-00-02?
    Yes. Alert reset and Danger reset each have latching or nonlatching selections. Verify both settings against the required protection sequence.
  • Which temperature and humidity conditions apply to 3300/20-11-01-01-00-02?
    The monitor operates from 0 to +65 °C and is specified for up to 95% relative humidity without condensation. The storage range is -40 to +85 °C.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.