Technical specifications for 3300/20-01-01-02-01-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/20-01-01-02-01-00
  • Estimated shipping dimensions:
    5.1×32×20.5cm
  • Weight:
    1.02 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Measurement channels:
    2 independent axial-position channels
  • Position scale:
    25-0-25 mils
  • Selected transducer sensitivity:
    200 mV/mil (approximately 8 V/mm)
  • Signal input impedance:
    10 kΩ
  • Nominal consumption:
    1.5 W
  • Signal-conditioning accuracy at +25 °C:
    ±0.33% full-scale typical; ±1% maximum
  • Recorder output selections:
    4–20 mA; 1–5 V DC; 0 to -10 V DC
  • Current recorder load:
    0–600 Ω
  • Voltage recorder minimum load:
    10 kΩ
  • Buffered output impedance:
    100 Ω
  • Alarm setpoint adjustment:
    0–100% full-scale; normal and counter directions
  • Alarm repeatability:
    Within 0.39% full-scale
  • Alarm delay selections:
    0.1, 1, 3 or 6 s
  • Relay construction:
    Hermetically sealed
  • Safety barrier configuration:
    None
  • Operating temperature:
    0 to +65 °C

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3300/20-01-01-02-01-00 compares two axial-position measurements with independently adjustable normal and counter-thrust alarm levels, helping detect movement toward either clearance boundary.
  • Provides separate 63-segment position displays for the two channels.
  • Offers bidirectional Alert and Danger thresholds.
  • Supports AND voting for the dual-relay alarm arrangement.
  • Provides a buffered transducer connection for each channel.

Two probes should observe the same thrust collar or shaft. An out-of-range gap signal can resemble actual axial movement, so dual-channel voting and correct probe adjustment are central to a dependable thrust-protection arrangement.

Important Notice: Verify the actual relay contact circuit and voting configuration before restoring protection. Hermetically sealed relays do not eliminate the need for two correctly adjusted proximity channels.

Bently Nevada 3300/20-01-01-02-01-00 Manuals & Downloads
Bently Nevada 3300/20-01-01-02-01-00 Official Technical Reference Excerpt (PDF)Bently Nevada 3300/20-01-01-02-01-00 Installation & Commissioning Guide (PDF)

The technical excerpt covers monitor characteristics and configuration choices. The installation guide addresses two-probe alignment, field connections, direction checks and alarm acceptance.

Thrust collar position
Measure axial displacement of the collar relative to bearing clearance.
Dual-channel thrust protection
Compare two probes observing the same collar or shaft.
Bidirectional axial travel
Apply normal and counter-thrust thresholds to the selected position scale.
Remote position recording
Send individually scaled channel outputs to a compatible receiver.
Check both axial-position channels and their alarm paths before returning Bently Nevada 3300/20-01-01-02-01-00 to service.
1
Identify both probes and the thrust collar they observe.
2
Record the current gap and normal-direction setting for each channel.
3
Check the 25-0-25 mils scale against the machine travel requirement.
4
Verify the 200 mV/mil input sensitivity and transducer supply.
5
Retain the selected hermetically sealed relay arrangement.
6
Confirm the intended unbarriered signal interface before reconnecting field wiring.
7
Test normal and counter Alert and Danger thresholds under the maintenance procedure.
8
Restore voting, reset, delay and bypass settings before returning protection to service.

Technical notes

Separate monitor accuracy, recorder-output accuracy, LCD resolution and alarm repeatability when assessing the complete measurement. The recorder-output error is additional to the signal-conditioning error.

FAQ View All FAQ

  • Why can a failed probe produce a thrust alarm on 3300/20-01-01-02-01-00?
    The monitor derives position from probe gap voltage. A failed or out-of-range transducer can resemble shaft movement; two probes observing the same collar with AND voting reduce this vulnerability.
  • Can 3300/20-01-01-02-01-00 alarm for movement on both sides of the zero position?
    Yes. Both Alert and Danger functions have normal and counter-thrust settings, adjustable from 0 to 100% of the selected full-scale range.
  • What does the hermetically sealed relay selection change on 3300/20-01-01-02-01-00?
    It specifies the alarm relay hardware. The monitored position range remains 25-0-25 mils, and the dual-channel alarm logic still needs to be configured for the application.
  • How much input-voltage change represents 10 mils of movement on 3300/20-01-01-02-01-00?
    At the selected 200 mV/mil sensitivity, 10 mils corresponds to a 2 V signal change. This is a calculated conversion; use the actual transducer polarity and normal-thrust setting to determine the indicated direction.
  • If a recorder circuit shorts, will 3300/20-01-01-02-01-00 lose its monitoring function?
    No. Monitor operation is unaffected by short circuits on the recorder outputs. Investigate the recorder wiring separately from the monitor and transducer functions.
  • How much load can the 4–20 mA output of 3300/20-01-01-02-01-00 drive?
    The stated load range is 0–600 Ω, with 0–12 V compliance across the load. Include the complete receiving-loop resistance when assessing the connection.
  • Which alarm-delay choices are available on 3300/20-01-01-02-01-00?
    Plug-in jumpers select 0.1, 1, 3 or 6 seconds. Check the installed delay rather than assuming it from the relay type or full-scale range.
  • What does a flashing Alert or Danger indicator identify on 3300/20-01-01-02-01-00?
    A flashing alarm LED indicates First Out when that function is enabled. Alert and Danger First Out indications are independent.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.