Match the complete marking
Include 1900/65A-00-00-01-00-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and terminal photos. Have your maintenance team compare the offered 1900/65A-00-00-01-00-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 1900/65A-00-00-01-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:1900/65A-00-00-01-00-00
-
Weight:1.3 kg
-
Tariff Code:8537101190
-
DC input supply:18-36 V DC
-
Operating current:0.35 A typical; 1.0 A maximum
-
Operating power:8.5 W typical; 14 W maximum
-
Transducer inputs:4; acceleration, velocity, radial vibration, thrust, position or speed
-
Temperature inputs:4; E/J/K/T thermocouples or 2-/3-wire RTDs
-
Relay outputs:6 SPDT; programmable logic
-
Maximum relay operands:50 per relay
-
Recorder outputs:4 x 4-20 mA; configurable channel/variable
-
Maximum recorder loop resistance:600 ohms
-
Recorder update interval:100 ms
-
Configuration retention:Non-volatile memory
-
Configuration interface:Built-in Ethernet
-
Display configuration:No display
-
Modbus option:Not included
-
DIN rail:35 mm
-
Operating temperature:-20 to +70 deg C
-
Operating humidity:95% maximum; non-condensing
Information
- Bently Nevada 1900/65A-00-00-01-00-00 brings vibration, position or speed measurements and temperature measurements into a standalone protection unit with configurable relay logic and analog recorder signals.
Outputs: Six programmable SPDT relays and four 4-20 mA recorder outputs
Configuration: Built-in Ethernet connection; no optional Modbus feature
Four transducer channels can process acceleration, velocity, radial vibration, thrust, position or speed according to the software configuration. Four separate temperature inputs support E, J, K or T thermocouples and two- or three-wire RTDs. Sensor type, processing mode and engineering units determine what each connected signal represents. Four independently assigned 4-20 mA recorder outputs convey selected variables to external receiving equipment. They update every 100 ms and support up to 600 ohms loop resistance under the applicable 18-36 V DC loop supply conditions. Output assignment and full-scale mapping are separate from the input channel numbering.
Six SPDT relays use programmable logic based on monitor, channel and variable status, with up to 50 operands per relay. AND logic ignores bypassed channels, while True AND includes them. Latching and normally energized or de-energized operation are configured independently, so bypass and reset behavior must be evaluated together with the actual voting expression.
1900/65A-00-00-01-00-00 Official Technical Reference Excerpt
1900/65A General Purpose Equipment Monitor, 173401 Rev. AC: preserved manufacturer specifications applicable to this product configuration. PDF · 8 pages.1900/65A-00-00-01-00-00 Installation & Verification Guide
Apter Power field guide for sensor assignment, configuration backup, relay-voting tests and recorder-loop verification. PDF · 5 pages.
Application scope: Use the monitor on general-purpose equipment that needs continuous machinery condition monitoring and protection. Machine-specific thresholds and relay actions must be engineered for the application.
Pump and fan monitoring
Combine suitable vibration channels with bearing-temperature inputs for continuously observed machinery.Temperature-assisted protection
Bring compatible thermocouples or RTDs into the same unit as mechanical-condition measurements.Relay-based machine interfaces
Implement reviewed channel-voting logic for separate warning or protective contacts.Analog recorder integration
Transmit selected variables to compatible analog inputs using independently assigned 4-20 mA outputs.
Verify DC power and DIN mount; do not assume a display or Modbus license is included.
Record transducer type, sensitivity, wiring and temperature-sensor selection.
Use the site-approved maintenance state before altering relays or alarm settings.
Match each recorder variable and full scale to the receiving input.
Test normal, alarm, Not OK, bypass and reset behavior against the approved logic.
Retain the approved configuration file and remove temporary inhibits before release.
Alternative Names
Technical notes
Communication boundary: The Ethernet configuration port remains usable, but the selected final 00 option does not include the Modbus Gateway.
Relay relationship: Contact behavior depends on both configured logic and energized/latching selections; verify the complete trip circuit.
FAQ View All FAQ
-
Can 1900/65A-00-00-01-00-00 be configured without an attached display?Yes. A PC uses the 1900 Configuration Software and built-in Ethernet connection to download and retrieve the configuration. The monitor stores the settings in non-volatile memory.
-
Does the Ethernet connector make 1900/65A-00-00-01-00-00 a Modbus-enabled unit?No. Ethernet configuration access and the optional Modbus Gateway are different functions. The final 00 option specifies no Modbus communication feature.
-
Which sensor categories can the four transducer inputs of 1900/65A-00-00-01-00-00 process?Software can configure the channels for acceleration, velocity, radial vibration, thrust, position or speed. The channel type and input electrical arrangement must match the connected sensor.
-
How can 1900/65A-00-00-01-00-00 combine alarms from several channels?Each of its six relay outputs can use a programmable logic statement based on OK, Alert and Danger states. AND, True AND and OR operations are available, with up to 50 operands per relay.
-
Can a recorder output on 1900/65A-00-00-01-00-00 report a different channel variable?Yes. Each of the four 4-20 mA outputs can be assigned a variable from a channel. The output is scaled to that channel full scale, so the receiving instrument must use the corresponding range.
-
What distinguishes AND from True AND in 1900/65A-00-00-01-00-00 relay logic?AND ignores bypassed channels, while True AND includes bypassed channels. This difference must be considered when proving the voting response during channel bypass or maintenance.
-
What happens when the reset input of 1900/65A-00-00-01-00-00 is activated?A reset clears latched alarm states and latched relays when the underlying alarm condition no longer exists. It does not remove an active physical fault or change the configured setpoints.
-
Which temperature wiring can 1900/65A-00-00-01-00-00 accept?Each temperature input supports E, J, K or T thermocouples and two- or three-wire RTDs. Configure the actual sensor type; two-wire RTD measurements also include lead-resistance error.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-