125760-01

Data Manager I/O Module
In Stock
Ships by Sunday, September 13
Fast Shipping Available

Product Describe:

Bently Nevada 125760-01 is a Data Manager I/O Module. It transfers static and dynamic rack data to supported external communication and acquisition processors.

Ask our team:

Get a quick price for: 125760-01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 125760-01

Technical specifications for 125760-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    125760-01
  • Estimated shipping dimensions:
    2.5x24.1x10.2 cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • I/O module type:
    Data Manager
  • Communication port sets:
    2
  • Protocol:
    Bently Nevada proprietary
  • Data rate:
    9600 baud fixed
  • Static data processors:
    TDIX; DDIX
  • Dynamic data processors:
    TDIX; DDIX
  • Maximum cable length:
    3 m
  • Rack connector interface:
    RS422
  • Rack connector data rate:
    38.4 kbaud maximum
  • Rear rack space:
    1 full-height slot
  • Matched front module:
    3500/20 RIM

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 125760-01 is the Data Manager I/O module for the 3500/20 Rack Interface Module. It transfers static and dynamic rack data to supported external communication and acquisition processors.
  • Provides two proprietary data-interface port sets at the rear of a 3500 rack
  • Transfers static and dynamic monitoring data to supported external processors
  • Connects the rack to TDXnet, TDIX or DDIX acquisition architectures
  • Maintains the short, fixed-rate communications path specified for the Data Manager interface

125760-01 installs with 3500 rack rear slot, 3500/20 RIM, TDXnet, TDIX or DDIX processor, Approved static and dynamic data cables in an engineered 3500/20 Rack Interface System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this data manager i/o module.

Important Notice: Confirm the complete 125760-01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 125760-01 Manuals and Guides
Apter Power 125760-01 Product Technical Reference PDFBently Nevada 125760-01 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Transient-data collectionProvides two proprietary data-interface port sets at the rear of a 3500 rack
Dynamic waveform acquisitionTransfers static and dynamic monitoring data to supported external processors
Rack static-value exportConnects the rack to TDXnet, TDIX or DDIX acquisition architectures
Legacy DDIX or TDIX interface restorationMaintains the short, fixed-rate communications path specified for the Data Manager interface
Read the applicable Bently Nevada installation instructions before work. Verify 125760-01 and the installed 3500/20 Rack Interface System configuration.
1Match 125760-01 to the rear slot of the designated 3500/20 RIM.
2Stop external acquisition sessions before disconnecting either Data Manager port set.
3Label static and dynamic data cables separately at both ends.
4Do not substitute a host-configuration serial cable for the Data Manager connection.
5Keep each TDIX or DDIX cable path within the published three-metre limit.
6Inspect rear connectors and use ESD controls before inserting the module.
7Restore the original external-processor channel and rack assignment.
8Confirm both static values and dynamic waveform data after restart.

Technical notes

Technical notes

Preserve both port-set identities and cable destinations, keep the data cables within the documented length and verify static plus dynamic data transfer before placing the acquisition system back in service.

FAQS

  • Which configuration should be restored after replacing 125760-01?
    Restore the approved 3500/20 Rack Interface System slot, channel or interface configuration and verify that every connected circuit retains its original assignment.
  • How can 125760-01 be commissioned for transient-data collection?
    Apply a controlled input or command, review the model-specific diagnostics and prove the expected measurement, indication and protection response before releasing the channel.
  • What technical value deserves special attention when checking 125760-01?
    Verify the published data rate value of 9600 baud fixed against the installed configuration and test record.
  • Can 125760-01 be exchanged with another 3500 I/O or monitor execution?
    Only when the complete part number, termination style, transducer or interface type and approved rack configuration match the installed duty; do not transfer settings from an adjacent model.
  • What evidence should be retained after 125760-01 returns to service?
    Retain the full 125760-01 identity, as-left connections, restored configuration, final diagnostics and the controlled functional-test result for dynamic waveform acquisition.
  • Which rack hardware must be matched before installing 125760-01?
    Match 125760-01 to the documented 3500 rack rear slot and 3500/20 RIM; confirm the front/rear slot pairing and the complete physical marking before connection.
  • What as-found information should an engineer record before removing 125760-01?
    Record every channel or port assignment, connector identity, configured function, cable tag and diagnostic state associated with 125760-01.
  • How should 125760-01 be isolated before field wiring is disturbed?
    Place the protected machine in its approved maintenance state, isolate rack and field energy applicable to TDXnet, TDIX or DDIX processor, and prove the terminals safe before disconnection.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.