X20SL8000

SafeLOGIC safety controller
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

B&R X20SL8000 is safelogic safety controller. It executes SafeLOGIC applications and coordinates safety nodes through POWERLINK in an X20 safety system.

Ask our team:

Get a quick price for: X20SL8000
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for X20SL8000

Technical specifications for X20SL8000

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    X20SL8000
  • Estimated shipping dimensions:
    9.8x2.5x5.5cm
  • Weight:
    0.06 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • Safety level:
    SIL 3; Cat. 4 / PL e
  • Maximum safety nodes:
    20
  • POWERLINK:
    100 Mbit/s
  • Shortest task class:
    1 ms
  • Supply:
    24 V DC -15% / +20%
  • Power consumption:
    5.1 W
  • Protection:
    IP20
  • Weight:
    290 g

Information

Information

Overview Manuals Common Applications Product Precautions
B&R X20SL8000 is safelogic safety controller. It executes SafeLOGIC applications and coordinates safety nodes through POWERLINK in an X20 safety system.
  • Executes SIL 3 safety applications
  • Coordinates up to twenty safety nodes
  • Communicates through 100 Mbit/s POWERLINK
  • Provides a one-millisecond shortest task class

X20SL8000 operates with X20 SafeLOGIC bus base, POWERLINK safety nodes, 24 V DC supply, SafeDESIGNER project and validation record.

Engineered applications include Machine safety controller, Networked emergency-stop logic, Safety motion coordination, SafeLOGIC controller renewal.

Important Notice: Record safety signatures and POWERLINK node identities, restore only the approved SafeDESIGNER project and repeat the complete validation procedure.

Apter Power X20SL8000 Manuals and Guides

Apter Power X20SL8000 Product and System Technical Reference PDFApter Power X20SL8000 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Machine safety controller

Runs the validated machine-safety program.

Networked emergency-stop logic

Coordinates distributed protective devices.

Safety motion coordination

Exchanges safety data with motion and I/O nodes.

SafeLOGIC controller renewal

Restores the controller while retaining validated signatures.

Read the applicable B&R instructions before work. Verify X20SL8000 and the installed B&R X20 safety control configuration.
1

Verify the full X20SL8000 marking and its assigned B&R X20 safety control position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and powerlink safety data and safelogic program execution field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed X20 SafeLOGIC bus base and POWERLINK safety nodes against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended machine safety controller function and retain the final test result.

Technical notes

Technical notes

Record safety signatures and POWERLINK node identities, restore only the approved SafeDESIGNER project and repeat the complete validation procedure.

FAQS

  • Which installed system position is intended for X20SL8000?
    Install X20SL8000 only in the documented B&R X20 safety control position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does X20SL8000 handle?
    Its documented duty is powerlink safety data and safelogic program execution; the official record lists maximum safety nodes as 20.
  • Which companion hardware must be matched to X20SL8000?
    Match X20SL8000 with X20 SafeLOGIC bus base and POWERLINK safety nodes, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring X20SL8000?
    Verify shortest task class: 1 ms. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing X20SL8000?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R X20 safety control configuration.
  • Which isolation and handling checks apply to X20SL8000?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling X20SL8000.
  • How should an engineer commission X20SL8000?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended machine safety controller function.
  • Can X20SL8000 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, safety level and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.