Technical specifications for X20SL8000
-
Manufacturer:B&R
-
Product Category:PLC Systems
-
Spare Part Number:X20SL8000
-
Tariff Code:8537101190
-
Counliy of origin:Austria
-
Safety level:SIL 3; Cat. 4 / PL e
-
Maximum safety nodes:20
-
POWERLINK:100 Mbit/s
-
Shortest task class:1 ms
-
Supply:24 V DC -15% / +20%
-
Power consumption:5.1 W
-
Protection:IP20
-
Weight:290 g
Information
- Executes SIL 3 safety applications
- Coordinates up to twenty safety nodes
- Communicates through 100 Mbit/s POWERLINK
- Provides a one-millisecond shortest task class
X20SL8000 operates with X20 SafeLOGIC bus base, POWERLINK safety nodes, 24 V DC supply, SafeDESIGNER project and validation record.
Engineered applications include Machine safety controller, Networked emergency-stop logic, Safety motion coordination, SafeLOGIC controller renewal.
Important Notice: Record safety signatures and POWERLINK node identities, restore only the approved SafeDESIGNER project and repeat the complete validation procedure.
Apter Power X20SL8000 Manuals and Guides
Apter Power X20SL8000 Product and System Technical Reference PDFApter Power X20SL8000 Installation and Commissioning Workbook PDFThe first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Machine safety controller
Runs the validated machine-safety program.
Networked emergency-stop logic
Coordinates distributed protective devices.
Safety motion coordination
Exchanges safety data with motion and I/O nodes.
SafeLOGIC controller renewal
Restores the controller while retaining validated signatures.
Verify the full X20SL8000 marking and its assigned B&R X20 safety control position before work.
Place the connected machine or process in the approved maintenance state.
Isolate the applicable supply and powerlink safety data and safelogic program execution field energy before disconnecting conductors.
Record connector, conductor, address and software identities before removal.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.
Confirm the installed X20 SafeLOGIC bus base and POWERLINK safety nodes against the approved project.
Restore power in a controlled sequence and review device, network and host diagnostics.
Prove the intended machine safety controller function and retain the final test result.
Technical notes
FAQ View All FAQ
-
Which installed system position is intended for X20SL8000?Install X20SL8000 only in the documented B&R X20 safety control position and verify the complete catalog marking against the approved hardware list.
-
What signal or controlled function does X20SL8000 handle?Its documented duty is powerlink safety data and safelogic program execution; the official record lists maximum safety nodes as 20.
-
Which companion hardware must be matched to X20SL8000?Match X20SL8000 with X20 SafeLOGIC bus base and POWERLINK safety nodes, including the documented carrier, cable and project identity.
-
Which electrical value must be verified before wiring X20SL8000?Verify shortest task class: 1 ms. Do not transfer limits from another catalog number.
-
How should the configuration be preserved when replacing X20SL8000?Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R X20 safety control configuration.
-
Which isolation and handling checks apply to X20SL8000?Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling X20SL8000.
-
How should an engineer commission X20SL8000?Power up in a controlled sequence, review device and host diagnostics, then prove the intended machine safety controller function.
-
Can X20SL8000 replace a visually similar module without further checks?No automatic substitution is assumed; compare the full catalog number, interfaces, safety level and approved system revision.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.