Match the complete marking
Include the complete B&R X20DC4395 marking and any hardware revision on the item. Capture encoder mode, counter width and every shared input/output assignment.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered X20DC4395 with the installed equipment and applicable B&R documents.
Technical specifications for X20DC4395
-
Manufacturer:B&R
-
Product Category:PLC Systems
-
Spare Part Number:X20DC4395
-
Weight:0.02 kg
-
Tariff Code:8537101190
-
Module supply:24 VDC -15% / +20%
-
SSI encoder capacity:2 absolute encoders
-
ABR encoder capacity:2 incremental encoders
-
AB encoder capacity:4 incremental encoders
-
Event counter capacity:8 counters
-
PWM outputs:4
-
Encoder input level:24 V asymmetrical
-
Incremental input frequency:100 kHz maximum
-
Counter size:16 or 32 bit
-
Encoder supply:Module internal, 600 mA maximum
-
Bus power consumption:0.01 W
-
Internal I/O power:1.5 W
-
Protection rating:IP20
Information
- B&R X20DC4395 brings position acquisition, pulse counting, timing and PWM generation into a configurable X20 I/O position.
Signal level: 24 V asymmetrical
PWM: Four outputs with 0.1% pulse-duration resolution
The 24 V asymmetrical encoder inputs support incremental signals up to 100 kHz. SSI communication uses Gray or binary coding at up to 125 kbit/s, with the encoder supply provided internally and protected against overload and short circuit.
Four outputs support push, pull or push-pull operation at 0.1 A per output. PWM, edge timing and event-controlled output operation can be combined with the selected input functions, so configuration must establish which channels own each signal before commissioning.
X20DC4395 Official Technical Excerpt
The original technical excerpt applicable to B&R X20DC4395 covers counter and SSI specifications, PWM ratings, terminals and diagnostics. PDF · 6 pages.X20DC4395 Installation & Verification Guide
Apter Power installation and verification guide covering encoder supply, channel allocation, SSI coding, counters and PWM tests. PDF · 5 pages.
Application scope: Select input and output functions according to the machine signal map; the published function counts cannot all be enabled simultaneously.
Absolute position
Two SSI interfaces accept Gray or binary coded encoder positions.Incremental motion
AB or ABR decoding tracks position and direction from 24 V encoders.Event timing
Edge-offset, period and gate-time measurements characterize machine events.Pulse control
PWM outputs drive compatible low-current control inputs.
Resolve conflicts between encoder inputs and output functions.
Use 24 V asymmetrical encoder signals.
Keep the internal encoder-supply load within 600 mA.
Respect 0.1 A per output and 0.4 A total.
Use shielded cable on every signal connection.
Verify counter width, coding and PWM period before testing.
Alternative Names
Technical notes
Signal and interface: The encoder supply supports a maximum 600 mA. The bus is isolated from the field circuitry, but field outputs and encoders are not mutually isolated.
Installation boundary: Use shielded signal lines. The four outputs have 0.1 A nominal current per channel and 0.4 A total nominal current.
Technical basis: B&R X20DC4395 Data sheet V3.30. Input, encoder and PWM capacities share the same eight channels; maximum function counts are alternative configurations.
FAQ View All FAQ
-
Which encoder types can B&R X20DC4395 connect?The module supports two SSI absolute encoders, two ABR encoders, four AB encoders or eight event counters, and the functions can be mixed.
-
What is the maximum incremental input frequency of B&R X20DC4395?The module accepts a maximum of 100 kHz for the 24 V asymmetrical incremental encoder inputs.
-
How many PWM outputs does B&R X20DC4395 provide?Four outputs are available for pulse-width modulation and can be combined with the selected input functions.
-
What encoder supply is available from B&R X20DC4395?The internal 24 V encoder supply supports up to 600 mA and is short-circuit and overload protected.
-
Must B&R X20DC4395 signal cables be shielded?Yes. Use shielded lines for all signal connections.
-
Which counter widths are available on B&R X20DC4395?The module supports 16-bit or 32-bit counter operation according to the configured function.
-
How is B&R X20DC4395 isolated?The bus is isolated from encoder and output circuitry; encoder and output groups are not mutually isolated inside the field side.
-
How should B&R X20DC4395 be accepted after replacement?Exercise every configured encoder or counter mode, confirm direction and scaling, check timestamps, test PWM outputs and verify diagnostics under controlled motion.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.