Speak to a sourcing specialist
sales13@apterpower.com

X20AT2222

Temperature Input Module
Ships by Sunday, November 8
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

B&R X20AT2222 acquires two Pt100/Pt1000 or resistance measurements with configurable two- or three-wire connections.
  • Manufacturer part number
    X20AT2222
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    9.7cm x 5.8cm x 1.1cm
  • Country of Origin
    Austria
Get a quick price for X20AT2222
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete B&R X20AT2222 reference, label photographs and required quantity. Include the installed rack/bus arrangement and actual hardware revision.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Include the complete B&R X20AT2222 marking and any hardware revision on the item. Include the installed rack/bus arrangement and actual hardware revision.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered X20AT2222 with the installed equipment and applicable B&R documentation.

Technical specifications for X20AT2222

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    X20AT2222
  • Weight:
    0.02 kg
  • Tariff Code:
    8537101190
  • Input channels:
    2
  • Sensor types:
    Pt100 / Pt1000
  • Sensor range:
    -200.0 to 850.0 degrees C
  • Temperature resolution:
    0.1 degrees C
  • Converter:
    16-bit sigma-delta
  • Measurement current:
    250 microamps +/-1.25%
  • Filter time:
    1-66.7 ms; configurable
  • Resistance ranges:
    0.1-4500 ohms /0.05-2250 ohms
  • Input filter:
    First-order;500 Hz
  • Isolation:
    Channels to bus; not between channels
  • Bus power:
    0.01 W
  • Internal I/O power:
    1.1 W

Information

Overview Downloads Applications / Compatibility Product Precautions
  • B&R X20AT2222 connects its configured field signals and diagnostic states to the automation task. Correct operation depends on retaining the installed hardware selection and the application settings together.
Input channels: 2
Sensor types: Pt100 / Pt1000
Sensor range: -200.0 to 850.0 degrees C
Each channel can select Pt100 or Pt1000 sensing, while the two- or three-wire arrangement is configured for the module. Internal linearization converts the sensor resistance to temperature with 0.1 degree resolution. Direct resistance measurement is also available in two ranges.

The 16-bit sigma-delta converter uses a constant measurement current of 250 microamps. Filter time is configurable from 1 to 66.7 ms. At the 50 Hz filter setting, conversion is 20 ms for one channel and 80 ms for two channels; these timings must be considered separately from the controller task period.

Input monitoring distinguishes lower limit, upper limit and open-circuit conditions. Invalid and fault values must be interpreted with the channel status rather than as real temperatures. Channels are isolated from the bus, but not from each other; terminal block and bus module are separate system components.
Controller platform reference: B&R X20 temperature measurement. Retain the installed hardware and application configuration.
The original technical excerpt for B&R X20AT2222 covers identity, interface limits and configuration behavior. The separate installation guide covers configuration retention, reconnection, functional tests and diagnostic recovery.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare B&R X20AT2222 for its configured installation using these checks.
Capture sensor and mode assignments

Record each channel sensor type and the module-wide two-/three-wire setting. Preserve the resistance or temperature operating mode, filter and assigned process point.

Put temperature-dependent control in maintenance

Prevent the affected loops from acting on disconnected-sensor fault values. Use the approved machine maintenance state and module exchange procedure.

Inspect the sensor circuit

Check for open circuits, damaged leads and incorrect two-/three-wire routing. Channel-to-channel isolation is not available to correct a wiring-reference error.

Restore the configuration

Load the retained sensor types, connection method and filter setting. Do not select Pt1000 solely to compensate for an incorrect resistance reading.

Test with known sensor values

Apply an approved resistance or temperature reference and compare both channel values. Use the configured range and 0.1 degree temperature resolution when assessing results.

Confirm timing and stable readings

Allow the selected filter and conversion cycle to settle. Compare both channels under stable input rather than assuming the controller cycle equals conversion time.

Alternative Names

B&R X20AT2222

Technical notes

Measurement status: Treat the channel status and measured value as one result. Fault and out-of-range substitutions must be handled before the value is used by the application.

Filter trade-off: Choose the measurement filter with both mains-frequency rejection and channel update time in mind; the fastest setting is not automatically the best temperature measurement setting.

FAQ View All FAQ

  • Can X20AT2222 use Pt100 on one channel and Pt1000 on the other?
    Yes. Sensor type is configurable per channel. The two-/three-wire connection arrangement is configured for the module.
  • What temperature increment is represented by X20AT2222?
    Temperature values have a 0.1 degree Celsius resolution for both Pt100 and Pt1000 sensing.
  • How does the 50 Hz filter affect conversion on X20AT2222?
    The conversion time is 20 ms for one channel and 80 ms for two channels at the 50 Hz filter setting.
  • Can X20AT2222 report resistance directly instead of temperature?
    Yes. Direct resistance ranges are 0.1-4500 ohms and 0.05-2250 ohms, depending on the configured operating mode.
  • What excitation does X20AT2222 apply to the sensor circuit?
    The resistance measurement uses a 250 microamp constant current with a specified tolerance of+/-1.25%.
  • Are the two input channels of X20AT2222 isolated from one another?
    No. The channel side is isolated from the bus, but channel-to-channel isolation is not provided.
  • Why must software check status as well as the value from X20AT2222?
    Open circuit, range errors and invalid conversions use defined substitute digital values. Interpreting only the numerical value can mistake a fault code for temperature.
  • Which terminal blocks can be used with X20AT2222?
    X20TB06 is the intended 6-pin block; X20TB12 may also be used. The selected bus module and terminal block must be included separately in the system arrangement.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.