Technical specifications for 3CP340.60-2
-
Manufacturer:B&R
-
Product Category:PLC Systems
-
Spare Part Number:3CP340.60-2
-
Tariff Code:8537101190
-
Counliy of origin:Austria
-
Processor:Intel Pentium; 166 MHz
-
DRAM:32 MB
-
SRAM:512 kB
-
Application storage:CompactFlash
-
Expansion:1 aPCI slot
-
Interfaces:USB; RS232; 100BASE-T Ethernet
Information
- Uses a 166 MHz Intel Pentium processor
- Provides 32 MB DRAM and 512 kB SRAM
- Includes one aPCI expansion slot
- Integrates 100BASE-T Ethernet
3CP340.60-2 operates with System 2005 rack, CompactFlash application media, approved aPCI interface module, Automation Studio project.
Engineered applications include System 2005 controller renewal, Ethernet PLC integration, Serial machine communication, Legacy application recovery.
Important Notice: Back up CompactFlash and SRAM-retained data, record aPCI hardware and interface addresses, then verify task timing and communications.
Apter Power 3CP340.60-2 Manuals and Guides
Apter Power 3CP340.60-2 Product and System Technical Reference PDFApter Power 3CP340.60-2 Installation and Commissioning Workbook PDFThe first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.
System 2005 controller renewal
Executes the installed System 2005 application.
Ethernet PLC integration
Links the controller to supervisory Ethernet.
Serial machine communication
Maintains serial equipment communication.
Legacy application recovery
Restores a legacy CPU from the approved backup.
Verify the full 3CP340.60-2 marking and its assigned B&R System 2005 PLC position before work.
Place the connected machine or process in the approved maintenance state.
Isolate the applicable supply and plc application execution plus ethernet, serial and apci data field energy before disconnecting conductors.
Record connector, conductor, address and software identities before removal.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.
Confirm the installed System 2005 rack and CompactFlash application media against the approved project.
Restore power in a controlled sequence and review device, network and host diagnostics.
Prove the intended system 2005 controller renewal function and retain the final test result.
Technical notes
FAQ View All FAQ
-
Which installed system position is intended for 3CP340.60-2?Install 3CP340.60-2 only in the documented B&R System 2005 PLC position and verify the complete catalog marking against the approved hardware list.
-
What signal or controlled function does 3CP340.60-2 handle?Its documented duty is plc application execution plus ethernet, serial and apci data; the official record lists dram as 32 MB.
-
Which companion hardware must be matched to 3CP340.60-2?Match 3CP340.60-2 with System 2005 rack and CompactFlash application media, including the documented carrier, cable and project identity.
-
Which electrical value must be verified before wiring 3CP340.60-2?Verify application storage: CompactFlash. Do not transfer limits from another catalog number.
-
How should the configuration be preserved when replacing 3CP340.60-2?Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R System 2005 PLC configuration.
-
Which isolation and handling checks apply to 3CP340.60-2?Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling 3CP340.60-2.
-
How should an engineer commission 3CP340.60-2?Power up in a controlled sequence, review device and host diagnostics, then prove the intended system 2005 controller renewal function.
-
Can 3CP340.60-2 replace a visually similar module without further checks?No automatic substitution is assumed; compare the full catalog number, interfaces, processor and approved system revision.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.