Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

X20BC8084

Expandable POWERLINK bus controller
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

B&R X20BC8084 is expandable powerlink bus controller. It couples expandable X20 I/O stations to a POWERLINK network and supports line or redundant connection arrangements.

Ask our team:

Get a quick price for: X20BC8084
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for X20BC8084

Technical specifications for X20BC8084

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    X20BC8084
  • Estimated shipping dimensions:
    10.2x6x2.5cm
  • Weight:
    0.06 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • B&R ID:
    0x2674
  • POWERLINK role:
    V1/V2 controlled node; Type 2
  • Ports:
    2 shielded RJ45
  • Physical layer:
    100BASE-TX
  • Data rate:
    100 Mbit/s
  • Maximum segment:
    100 m
  • Minimum fieldbus/X2X cycle:
    200 us
  • Bus power consumption:
    2 W

Information

Information

Overview Manuals Common Applications Product Precautions
B&R X20BC8084 is expandable powerlink bus controller. It couples expandable X20 I/O stations to a POWERLINK network and supports line or redundant connection arrangements.
  • Operates as a POWERLINK controlled node
  • Provides two shielded RJ45 ports
  • Transfers X20 data with 200-microsecond minimum cycles
  • Supports link selection and redundancy

X20BC8084 operates with X20 bus base and I/O slices, POWERLINK cable and switch, 24 V DC station supply, Automation Studio hardware configuration.

Engineered applications include Remote X20 I/O station, POWERLINK line topology, Redundant distributed-I/O link, Bus-controller replacement.

Important Notice: Record the node number, cable port order and X2X configuration before replacement; verify both link directions and I/O diagnostics after startup.

Apter Power X20BC8084 Manuals and Guides

Apter Power X20BC8084 Product and System Technical Reference PDFApter Power X20BC8084 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Remote X20 I/O station

Connects remote X20 slices to the controller.

POWERLINK line topology

Extends a deterministic POWERLINK line.

Redundant distributed-I/O link

Supports an engineered redundant communication path.

Bus-controller replacement

Restores the node while preserving network identity.

Read the applicable B&R instructions before work. Verify X20BC8084 and the installed B&R X20 distributed I/O configuration.
1

Verify the full X20BC8084 marking and its assigned B&R X20 distributed I/O position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and powerlink network frames and x20 i/o process data field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed X20 bus base and I/O slices and POWERLINK cable and switch against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended remote x20 i/o station function and retain the final test result.

Technical notes

Technical notes

Record the node number, cable port order and X2X configuration before replacement; verify both link directions and I/O diagnostics after startup.

FAQS

  • Which installed system position is intended for X20BC8084?
    Install X20BC8084 only in the documented B&R X20 distributed I/O position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does X20BC8084 handle?
    Its documented duty is powerlink network frames and x20 i/o process data; the official record lists powerlink role as V1/V2 controlled node; Type 2.
  • Which companion hardware must be matched to X20BC8084?
    Match X20BC8084 with X20 bus base and I/O slices and POWERLINK cable and switch, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring X20BC8084?
    Verify physical layer: 100BASE-TX. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing X20BC8084?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R X20 distributed I/O configuration.
  • Which isolation and handling checks apply to X20BC8084?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling X20BC8084.
  • How should an engineer commission X20BC8084?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended remote x20 i/o station function.
  • Can X20BC8084 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, b&r id and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.