Technical specifications for PW482-S01

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    PW482-S01
  • Estimated shipping dimensions:
    5x14.9x19.9cm
  • Weight:
    0.92 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Japan
  • Input voltage:
    220 to 240 V AC ±10%
  • Input frequency:
    50/60 Hz ±3 Hz
  • Maximum power consumption:
    230 VA
  • Interface:
    Exclusive connector
  • Installation units:
    FCU, FIO Node Unit and Optical ESB Bus Repeater Unit
  • Redundancy:
    Two-module dual-redundant configuration
  • Output use:
    Exclusive internal unit power; not a generic supply

Information

Overview Manuals Common Applications Product Precautions
PW482-S01 feeds the internal unit power bus through an exclusive connector and can form a dual-redundant supply pair when two modules are installed.
  • Accepts 220 to 240 V AC input.
  • Connects through the unit's exclusive power connector.
  • Installs in supported FCU, FIO and optical repeater units.
  • Supports a two-module dual-redundant power arrangement.

PW482-S01 should be matched to the documented system position, companion hardware and retained project configuration before the channel or station is returned to control.

Important Notice: Preserve the complete PW482-S01 identity and verify its documented electrical, network or signal response before release.

Yokogawa PW482-S01 Manuals & Downloads
Yokogawa PW482-S01 Official Technical Reference Excerpt (PDF)Yokogawa PW482-S01 Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Field control unit power
Supplies compatible FCU internal electronics.
FIO node power
Feeds supported field I/O node units.
Optical ESB repeater power
Operates the documented bus repeater unit.
Redundant station supply
Pairs two modules to maintain the configured dual power path.
Before installing Yokogawa PW482-S01, confirm the documented system, interfaces and controlled configuration.
1
Confirm the full PW482-S01 marking and assigned power slot.
2
Record incoming voltage, breaker and redundant-module status.
3
Isolate both supply paths before removing the module.
4
Do not use the module as a general-purpose external DC supply.
5
Inspect the exclusive connector and retention hardware.
6
Install the module without disturbing the companion supply.
7
Energize one documented path at a time and watch fault indications.
8
Verify unit power, redundancy and controller or node operation before release.

Technical notes

Preserve the complete PW482-S01 identity and verify its documented electrical, network or signal response before release.

FAQ View All FAQ

  • Which mains range is specified for Yokogawa PW482-S01?
    The module accepts 220 to 240 V AC with a tolerance of ±10 percent.
  • How tightly is input frequency defined for Yokogawa PW482-S01?
    The documented input is 50 or 60 Hz with a tolerance of ±3 Hz.
  • What is the maximum input demand of Yokogawa PW482-S01?
    Maximum power consumption is 230 VA.
  • Can Yokogawa PW482-S01 be wired as a generic external power supply?
    No. Yokogawa specifies it as an exclusive module for supported control and node units, so external output ratings are not defined.
  • Which units accept Yokogawa PW482-S01?
    Supported installations include field control units, FIO node units and Optical ESB Bus Repeater Units.
  • How is dual redundancy obtained with Yokogawa PW482-S01?
    Install two documented power modules in the supported unit to form the dual-redundant supply configuration.
  • Which connector must be checked on Yokogawa PW482-S01?
    The module uses the unit's exclusive power connector; inspect alignment, contact condition and retention.
  • What should be observed after energizing Yokogawa PW482-S01?
    Confirm normal unit power, absence of supply faults, healthy companion-module status and uninterrupted controller or node operation.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.