Technical specifications for TI-405-4DAC-2

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    405-4DAC-2
  • Estimated shipping dimensions:
    10.2x15.2x5.1cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Output channels:
    4
  • Resolution:
    12 bit
  • Current ranges:
    0 to 20 mA; 4 to 20 mA
  • Voltage ranges:
    0 to 5 V; 0 to 10 V; ±5 V; ±10 V
  • User supply:
    24 V DC
  • Compatibility reference:
    F4-04DA compatibility mode
  • Acceptance focus:
    Confirm end-to-end response

Information

Overview Manuals Common Applications Product Precautions
Siemens TI-405-4DAC-2 performs the four-channel analog output module function within the SIMATIC TI 405 platform while retaining the interfaces assigned to its installed position.
  • Provides the four-channel analog output module function.
  • Integrates with the SIMATIC TI 405 platform.
  • Retains the assigned signal or communication path.
  • Uses the complete TI-405-4DAC-2 identity for replacement control.

The four-channel analog output module should remain matched to its installed terminals, configuration and receiving system. Verify the complete path after replacement.

Important Notice: Match Siemens TI-405-4DAC-2 to the installed position, terminals and controlled configuration. Verify the complete signal or communication path before release.

Siemens TI-405-4DAC-2 Manuals & Downloads
Siemens TI-405-4DAC-2 Technical Reference (PDF)Siemens TI-405-4DAC-2 Installation & Commissioning Guide (PDF)

The first PDF covers the product function and technical data. The second covers connection checks, commissioning and release steps.

Installed-base maintenance
Restore the assigned four-channel analog output module position without changing the surrounding system design.
Loop and channel service
Retain terminal assignments, scaling and channel ownership during controlled replacement.
Fault isolation
Separate module, field wiring and configuration causes during troubleshooting.
Commissioning
Prove the complete signal path before returning the process to service.
Apply these checks to the exact Siemens TI-405-4DAC-2 position before isolation, replacement or release.
1
Confirm the complete Siemens TI-405-4DAC-2 marking before removal.
2
Place the affected SIMATIC TI 405 function in its approved maintenance state.
3
Record terminals, connectors and installed orientation before disconnection.
4
Retain channel assignments, scaling and communication settings.
5
Inspect mating contacts and terminal hardware for damage or contamination.
6
Restore shields, commons and protective grounding exactly as assigned.
7
Energize under controlled conditions and review module status.
8
Verify the end-to-end process response before release.

Technical notes

Match Siemens TI-405-4DAC-2 to the installed position, terminals and controlled configuration. Verify the complete signal or communication path before release.

FAQ View All FAQ

  • What is Siemens TI-405-4DAC-2 designed to do?
    It provides the four-channel analog output module function for SIMATIC TI 405.
  • How is Siemens TI-405-4DAC-2 integrated into the control system?
    It occupies the assigned SIMATIC TI 405 position and retains the surrounding interfaces.
  • Which resolution is specified for Siemens TI-405-4DAC-2?
    Resolution: 12 bit.
  • What should be checked about the current ranges on Siemens TI-405-4DAC-2?
    Confirm 0 to 20 mA; 4 to 20 mA before energization.
  • Which voltage ranges belongs to Siemens TI-405-4DAC-2?
    The applicable value is 0 to 5 V; 0 to 10 V; ±5 V; ±10 V.
  • How should technicians preserve the user supply of Siemens TI-405-4DAC-2?
    Record and restore 24 V DC.
  • Which acceptance test applies after Siemens TI-405-4DAC-2 is installed?
    Verify the static state, controlled dynamic response and final SIMATIC TI 405 status.
  • What must match before Siemens TI-405-4DAC-2 returns to service?
    The model marking, installed position, connections, configuration and end-to-end response must all agree.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.