Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

505-4532

32-Point DC Output Module
In Stock
Ships by Monday, October 26
Fast Shipping Available

Product Describe:

Siemens 505-4532 is a single-wide SIMATIC 505 module with 32 non-latching DC outputs for 6 to 24 V DC loads.

Ask our team:

Get a quick price for: 505-4532
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 505-4532

Technical specifications for 505-4532

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    505-4532
  • Estimated shipping dimensions:
    4.1x18.6x26.6cm
  • Weight:
    0.6 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Output channels:
    32
  • Rated load supply:
    6 to 24 V DC
  • Operating range:
    4.5 to 34 V DC
  • Minimum load:
    5 mA
  • Overload:
    2.0 A for 1 ms
  • ON-state drop:
    1.8 V DC
  • OFF-state leakage:
    0.2 mA
  • Protection:
    Diode kickback; reverse-voltage protection to 34 V DC
  • Output behavior:
    Non-latching, unprotected
  • Module format:
    Single-wide

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 505-4532 switches thirty-two DC field loads from a single SIMATIC 505 rack position.
  • Provides 32 DC output channels.
  • Supports a 6 to 24 V DC rated load supply.
  • Uses diode kickback protection for inductive loads.
  • Provides approximately 1 ms ON and OFF delay.

The 32-point dc output module belongs to the SIMATIC 505 modular control platform. Selection must preserve the documented signal role, terminal arrangement and rack interface.

Important Notice: Verify the complete Siemens 505-4532 marking, terminal assignment, rack position and configured signal behavior before replacement.

Siemens 505-4532 Manuals & Downloads
Siemens 505-4532 Technical Reference (PDF)Siemens 505-4532 Installation & Commissioning Guide (PDF)

The Technical Reference covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Solenoid control
Drive approved DC solenoids within the channel and group load limits.
Indicator and relay drive
Switch pilot lights and interposing relays from controller logic.
Machine sequencing
Operate distributed DC actuators under PLC interlocks.
Existing-rack maintenance
Restore the documented 32-point DC output map in a SIMATIC 505 station.
Before installing Siemens 505-4532, confirm the documented system, interfaces and controlled configuration.
1
Confirm the load supply remains within the documented DC range.
2
Isolate both rack power and external load power before service.
3
Record every output, common and supply connection before removal.
4
Check inductive loads and retain suitable suppression at the field device.
5
Confirm group current and individual load current remain within the approved design.
6
Replace the fuse only with the documented type and rating.
7
Verify output polarity before energizing the field supply.
8
Command each output under controlled conditions and confirm the load response.

Technical notes

Technical notes

Verify the complete Siemens 505-4532 marking, terminal assignment, rack position and configured signal behavior before replacement.

FAQS

  • How many loads can Siemens 505-4532 address?
    The module provides 32 DC output channels.
  • Which supply range is rated for Siemens 505-4532?
    Its rated load supply is 6 to 24 V DC, with a documented operating range of 4.5 to 34 V DC.
  • What minimum load applies to Siemens 505-4532?
    Each output requires at least 5 mA.
  • How does Siemens 505-4532 handle inductive switching?
    The outputs include diode kickback protection; field-device suppression and wiring must still follow the approved design.
  • Are Siemens 505-4532 outputs latching?
    No. They are documented as non-latching outputs.
  • What switching delay is typical for Siemens 505-4532?
    The documented ON and OFF delays are approximately 1 ms.
  • Which wiring checks are essential before powering Siemens 505-4532?
    Confirm polarity, group commons, load supply and every channel assignment.
  • How is Siemens 505-4532 functionally tested?
    Command each channel and verify the intended DC load changes state without an unexpected fault.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.