505-6108

8-Channel Analog Input Module
In Stock
Ships by Tuesday, October 27
Fast Shipping Available

Product Describe:

Siemens 505-6108 is the legacy double-wide, eight-channel analog input module in the SIMATIC 505 family and is the wiring-compatible predecessor to the single-wide 505-6108A and 505-6108B versions.

Ask our team:

Get a quick price for: 505-6108
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 505-6108

Technical specifications for 505-6108

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    505-6108
  • Estimated shipping dimensions:
    2x20.1x26.6cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Signal role:
    Analog input
  • Input channels:
    8
  • Module generation:
    Legacy predecessor to 505-6108A and 505-6108B
  • Module format:
    Double-wide
  • Replacement wiring:
    Later single-wide versions can replace it without field-wiring changes
  • Base power:
    4.0 W

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 505-6108 acquires eight analog input channels through the earlier double-wide SIMATIC 505 module format.
  • Provides eight analog input channels.
  • Uses the earlier double-wide module format.
  • Shares field wiring compatibility with the later 505-6108A and 505-6108B versions.
  • Uses the SIMATIC 505 analog input data path.

The 8-channel analog input module belongs to the SIMATIC 505 modular control platform. Selection must preserve the documented signal role, terminal arrangement and rack interface.

Important Notice: Verify the complete Siemens 505-6108 marking, terminal assignment, rack position and configured signal behavior before replacement.

Siemens 505-6108 Manuals & Downloads
Siemens 505-6108 Technical Reference (PDF)Siemens 505-6108 Installation & Commissioning Guide (PDF)

The Technical Reference covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Process measurement
Acquire eight conditioned analog values for the controller.
Legacy rack support
Maintain the earlier double-wide analog input position.
Migration planning
Prepare a controlled transition to the wiring-compatible single-wide A or B execution.
Troubleshooting
Trace the field signal, terminal path and controller word for each channel.
Before installing Siemens 505-6108, confirm the documented system, interfaces and controlled configuration.
1
Confirm that the installed module is the legacy 505-6108 execution.
2
Reserve the double-wide rack position before installation.
3
Record every analog channel, return and shield termination.
4
Preserve the configured signal type, range and scaling for each channel.
5
Isolate field loops according to the approved process procedure.
6
Keep analog wiring separated from noise-producing conductors.
7
Verify channel values against retained process references after power-up.
8
Complete a controlled migration review before substituting an A or B version.

Technical notes

Technical notes

Verify the complete Siemens 505-6108 marking, terminal assignment, rack position and configured signal behavior before replacement.

FAQS

  • How many analog inputs are available on Siemens 505-6108?
    The module provides eight analog input channels.
  • Which rack format is used by Siemens 505-6108?
    The legacy execution is double-wide.
  • Which later modules are related to Siemens 505-6108?
    The 505-6108A and 505-6108B are single-wide successors.
  • Can a later Siemens 505-6108A or 505-6108B reuse the 505-6108 field wiring?
    The manual states that the single-wide versions can replace the older module without wiring changes; configuration and acceptance still require verification.
  • What base-power demand is listed for Siemens 505-6108?
    The SIMATIC 505 system manual lists 4.0 W.
  • Which records should be captured before removing Siemens 505-6108?
    Record every channel, return, shield, signal range, scaling and rack position.
  • How should Siemens 505-6108 values be checked after startup?
    Compare each controller value with a retained process reference across the expected range.
  • What is required before migrating Siemens 505-6108 to a later version?
    Verify rack space, configuration, signal ranges, terminal assignments and the complete acceptance test.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.