6DR2104-4

Continuous Process Controller with Analog Current Inputs and Output
Siemens 6DR2104-4
Siemens 6DR2104-4
Siemens 6DR2104-4
Siemens 6DR2104-4
Siemens 6DR2104-4
Siemens 6DR2104-4
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6DR2104-4 is a SIPART DR21 K-controller with a 24 V UC supply option and continuous analog control output.
  • Manufacturer part number
    6DR2104-4
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    7.2cm x 17.5cm x 14.4cm
  • Country of Origin
    Germany
Get a quick price for 6DR2104-4
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Siemens 6DR2104-4 reference, label photographs and required quantity.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Provide the complete Siemens 6DR2104-4 marking.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 6DR2104-4 with the installed equipment and applicable Siemens instructions.

Technical specifications for 6DR2104-4

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6DR2104-4
  • Weight:
    0.74 kg
  • Tariff Code:
    8537101190
  • Controller execution:
    K-controller, continuous output
  • Nominal power supply:
    24 V UC
  • AC supply range:
    20–28 V AC
  • DC supply range:
    20–35 V DC
  • Standard analog inputs:
    2 current inputs, AI1 and AI2
  • Input signal range:
    0/4–20 mA
  • Input resistance:
    248 Ω ±1%
  • Input filter time constant:
    10 ms
  • Analog output range:
    0–20 mA or 4–20 mA
  • Control cycle:
    100 ms
  • Digital-input low state:
    ≤4.5 V or open
  • Digital-input high state:
    ≥13 V

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6DR2104-4 compares process and setpoint signals and delivers a continuous manipulated-variable signal for a configured single-loop process.
Loop regulation: Convert measured process deviation into a controlled analog command.
Configuration flexibility: Assign the available signals to the retained process-control strategy.
Operating coordination: Manual, automatic and digital selections must agree with the intended actuator response.
This continuous-output controller closes a process loop using the assigned measured value, setpoint and manipulated variable. The retained strategy determines how the available inputs participate in regulation.

The output command must be interpreted consistently by the receiving valve, drive or other actuator. Matching electrical ranges is therefore part of preserving the original process relationship.

Manual operation and configured digital selections affect how the loop is operated. Their behavior belongs to the commissioned control strategy and must remain consistent when restoring automatic regulation.
Controller platform reference: Siemens SIPART DR21. Match the installed configuration and applicable instructions.
Siemens 6DR2104-4: original manufacturer technical information covering the specified interfaces and operating limits. Installation topics include: capture the loop configuration, confirm the -4 supply, inspect fitted option modules, validate engineering scaling, exercise digital selections.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
Prepare Siemens 6DR2104-4 for its configured installation using these checks.
Secure the process output

Transfer the process to its approved maintenance or manual-control arrangement. Establish how the actuator responds to loss of current so controller removal cannot cause an unintended valve or drive movement.

Trace AI1 and AI2

Label both current loops and their common references. Check transmitter polarity, selected 0/4–20 mA ranges and the effect of the 248-ohm burden before reconnecting the process and setpoint signals.

Restore the analog-output range

Match the output's 0–20 or 4–20 mA setting to the receiving device. Review loop loading and polarity, then verify a controlled low, intermediate and high command without exposing the process to unsafe movement.

Check the control direction

With the process secured, confirm that an input deviation changes the manipulated variable in the intended direction. Recheck limits and manual-to-automatic transfer behavior before enabling closed-loop control.

Release the restored loop

Review the final configuration with the responsible process operator. Record reference-input and output-check results, then return to automatic operation under the site's controlled commissioning procedure.

Exercise digital selections

Test any wired digital-input functions against their assigned actions. Confirm definite low and high states rather than relying on an intermediate voltage, and retain the correct common reference throughout the test.

Alternative Names

Siemens 6DR2104-4 6DR2104 4

Technical notes

Operating boundary: Use the K-controller and 24 V UC configuration for this exact reference.

Integration details: Restore input/output ranges, optional modules and control action before closing the process loop.

FAQ View All FAQ

  • Why can 6DR2104-4 display the right process value while driving an actuator in the wrong direction?
    Input scaling and controller action are separate settings. With the process secured, introduce an approved deviation and verify that the output moves in the corrective direction before enabling automatic control.
  • How does the input burden of 6DR2104-4 affect a transmitter loop?
    The transmitter must maintain the required current through the combined controller burden, wiring and other connected loads. A current error under load can therefore originate in loop compliance rather than in input scaling.
  • What should be assessed before changing 6DR2104-4 from 0–20 mA to 4–20 mA?
    Check both the configured range and the receiving or transmitting device. Revalidate the low, intermediate and high points so the live-zero offset does not become a process scaling error.
  • Why must AI1 and AI2 assignments be retained on 6DR2104-4?
    Their functions depend on the controller configuration. Interchanging process and external-setpoint signals can preserve plausible readings while changing the control strategy.
  • Can 6DR2104-4 filter time be treated as the complete loop response time?
    No. Filtering, controller execution, output behavior and the process each contribute. Evaluate the full loop response before using a filter change to address oscillation or noise.
  • What is the useful test during manual-to-automatic transfer on 6DR2104-4?
    Observe the commanded output and actual actuator response under the approved commissioning conditions. Confirm that the retained limits and control direction produce the intended transition.
  • How should uncertain digital selection states be investigated on 6DR2104-4?
    Verify the applied voltage and common reference against the defined input states, then compare the configured action. Do not infer an enabled function from an intermediate voltage.
  • Why should optional I/O not be assumed when integrating 6DR2104-4?
    An option described for the controller family is not proof it is fitted to the offered unit. Match the physical interfaces and retained configuration before allocating additional field signals.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.