Technical specifications for 6DR2104-4
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6DR2104-4
-
Weight:0.74 kg
-
Tariff Code:8537101190
-
Controller execution:K-controller, continuous output
-
Nominal power supply:24 V UC
-
AC supply range:20–28 V AC
-
DC supply range:20–35 V DC
-
Standard analog inputs:2 current inputs, AI1 and AI2
-
Input signal range:0/4–20 mA
-
Input resistance:248 Ω ±1%
-
Input filter time constant:10 ms
-
Analog output range:0–20 mA or 4–20 mA
-
Control cycle:100 ms
-
Digital-input low state:≤4.5 V or open
-
Digital-input high state:≥13 V
Information
- Siemens 6DR2104-4 compares process and setpoint signals and delivers a continuous manipulated-variable signal for a configured single-loop process.
Configuration flexibility: Assign the available signals to the retained process-control strategy.
Operating coordination: Manual, automatic and digital selections must agree with the intended actuator response.
The output command must be interpreted consistently by the receiving valve, drive or other actuator. Matching electrical ranges is therefore part of preserving the original process relationship.
Manual operation and configured digital selections affect how the loop is operated. Their behavior belongs to the commissioned control strategy and must remain consistent when restoring automatic regulation.
6DR2104-4 Official Technical Excerpt
Siemens 6DR2104-4: original manufacturer technical information covering the specified interfaces and operating limits. PDF · 6 pages.6DR2104-4 Installation & Verification Guide
Apter Power guide covering loop preparation, supply and inputs, options and output, control direction, process release. PDF · 5 pages.
Application boundary: Signal assignment and optional hardware follow the installed control configuration; relay-output features of other executions are not assumed.
Continuous process regulation
A configured current-input loop drives a continuous manipulated-variable output.External setpoint operation
The second standard current input can serve the function assigned by the retained controller configuration.Analog actuator interfacing
A 0–20 or 4–20 mA output connects the controller to a compatible actuator input.Configured external selections
Wired digital selections can participate in the control strategy when their assigned functions match the installed loop.
Transfer the process to its approved maintenance or manual-control arrangement. Establish how the actuator responds to loss of current so controller removal cannot cause an unintended valve or drive movement.
Label both current loops and their common references. Check transmitter polarity, selected 0/4–20 mA ranges and the effect of the 248-ohm burden before reconnecting the process and setpoint signals.
Match the output's 0–20 or 4–20 mA setting to the receiving device. Review loop loading and polarity, then verify a controlled low, intermediate and high command without exposing the process to unsafe movement.
With the process secured, confirm that an input deviation changes the manipulated variable in the intended direction. Recheck limits and manual-to-automatic transfer behavior before enabling closed-loop control.
Review the final configuration with the responsible process operator. Record reference-input and output-check results, then return to automatic operation under the site's controlled commissioning procedure.
Test any wired digital-input functions against their assigned actions. Confirm definite low and high states rather than relying on an intermediate voltage, and retain the correct common reference throughout the test.
Alternative Names
Technical notes
Operating boundary: Use the K-controller and 24 V UC configuration for this exact reference.
Integration details: Restore input/output ranges, optional modules and control action before closing the process loop.
FAQ View All FAQ
-
Why can 6DR2104-4 display the right process value while driving an actuator in the wrong direction?Input scaling and controller action are separate settings. With the process secured, introduce an approved deviation and verify that the output moves in the corrective direction before enabling automatic control.
-
How does the input burden of 6DR2104-4 affect a transmitter loop?The transmitter must maintain the required current through the combined controller burden, wiring and other connected loads. A current error under load can therefore originate in loop compliance rather than in input scaling.
-
What should be assessed before changing 6DR2104-4 from 0–20 mA to 4–20 mA?Check both the configured range and the receiving or transmitting device. Revalidate the low, intermediate and high points so the live-zero offset does not become a process scaling error.
-
Why must AI1 and AI2 assignments be retained on 6DR2104-4?Their functions depend on the controller configuration. Interchanging process and external-setpoint signals can preserve plausible readings while changing the control strategy.
-
Can 6DR2104-4 filter time be treated as the complete loop response time?No. Filtering, controller execution, output behavior and the process each contribute. Evaluate the full loop response before using a filter change to address oscillation or noise.
-
What is the useful test during manual-to-automatic transfer on 6DR2104-4?Observe the commanded output and actual actuator response under the approved commissioning conditions. Confirm that the retained limits and control direction produce the intended transition.
-
How should uncertain digital selection states be investigated on 6DR2104-4?Verify the applied voltage and common reference against the defined input states, then compare the configured action. Do not infer an enabled function from an intermediate voltage.
-
Why should optional I/O not be assumed when integrating 6DR2104-4?An option described for the controller family is not proof it is fitted to the offered unit. Match the physical interfaces and retained configuration before allocating additional field signals.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.