Match the complete marking
Include 6FC5370-4AM20-0AA0 and any hardware revision or assembly markings visible on the item. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered 6FC5370-4AM20-0AA0 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6FC5370-4AM20-0AA0
-
Manufacturer:Siemens
-
Product Category:General Automation
-
Spare Part Number:6FC5370-4AM20-0AA0
-
Weight:4.52 kg
-
Tariff Code:8537101190
-
Product series:SINUMERIK 828D Basic M
-
PPU execution:PPU 240.2
-
Mounting position:Vertical
-
Supply voltage:24 V DC, +20% / -15%
-
Maximum active power:60 W
-
Power-interruption buffering:3 ms; 20 ms with applicable SITOP smart supply
-
Front protection:IP65 with front flap closed
-
Rear protection:IP20 / UL open type
-
Front operating temperature:0 to +45 °C
-
Rear operating temperature:0 to +55 °C
-
Operating humidity:5 to 90% at 25 °C; no condensation or icing
Information
- The hardware identity must be considered together with the installed CNC software and machine configuration; supplying the PPU does not by itself establish the available software options or the complete machine function.
Product series: SINUMERIK 828D Basic M
PPU execution: PPU 240.2
The PPU uses a 24 V DC supply with a permitted positive tolerance of 20 percent and negative tolerance of 15 percent. Maximum active power consumption is 60 W. Power-interruption buffering is 3 ms, with 20 ms specified when used with the applicable SITOP smart supply arrangement. Supply selection and the machine restart behavior should be checked together before the replacement is energized.
The front provides IP65 protection with its flap closed, while the rear is IP20 / UL open type and requires the corresponding protected installation. Operating temperature is 0 to 45 degrees Celsius at the front and 0 to 55 degrees Celsius at the rear; condensation and icing are excluded. Preserve the vertical mounting arrangement, CNC and PLC backups, machine data and fitted interface assignments, then validate the restored machine through the approved commissioning procedure.
-
Siemens 6FC5370-4AM20-0AA0 technical reference
Original Siemens technical excerpt - PDF, 1 pages. Product-specific technical information and applicable configuration details. -
Siemens 6FC5370-4AM20-0AA0 installation guide
Prepared by Apter Power - PDF, 5 pages. Model identification, interface checks, configuration review and commissioning verification.
Application scope: Data applies to the vertical PPU 240.2 hardware execution. CNC software, licensed options and machine-specific functions require separate configuration matching.
-
Configured CNC operation
Use the exact PPU with the matching CNC software, options and machine configuration. -
Machine control restoration
Restore the approved CNC and PLC backups when replacing the panel-processing hardware. -
Operator-panel integration
Preserve the vertical mounting and separate front/rear environmental protection. -
Power and restart verification
Validate the DC supply and machine-specific response to interruption and controlled restart.
Match 6FC5370-4AM20-0AA0, PPU 240.2, the hardware revision and the vertical panel arrangement.
Match the CNC software, PLC program, machine data and configured peripheral interfaces.
Verify the 24 V DC supply, available power and separate front/rear protection and temperature conditions.
Restore the approved backups and verify the machine-specific functions, diagnostics and controlled restart.
Use the applicable isolation and electrostatic-discharge controls. Preserve connectors, identification and mechanical retention during handling.
Apply the approved site acceptance procedure and compare actual behavior with the recorded system configuration before returning equipment to service.
Alternative Names
Technical notes
System relationship: Match the CNC software, PLC program, machine data and configured peripheral interfaces.
Applicability: Data applies to the vertical PPU 240.2 hardware execution. CNC software, licensed options and machine-specific functions require separate configuration matching.
Technical reference: Siemens 6FC5370-4AM20-0AA0 Product Data Sheet; SINAMICS S120 Combi Equipment Manual, 01/2012.
FAQ View All FAQ
-
Which PPU is supplied as 6FC5370-4AM20-0AA0?It is the vertical PPU 240.2 hardware execution for SINUMERIK 828D Basic M.
-
What DC supply tolerance applies to 6FC5370-4AM20-0AA0?The supply is 24 V DC with +20% and -15% tolerance.
-
How much active power can 6FC5370-4AM20-0AA0 consume?Maximum active power consumption is 60 W.
-
What interruption buffering is specified for 6FC5370-4AM20-0AA0?The PPU provides 3 ms, with 20 ms specified for the applicable SITOP smart supply arrangement.
-
When does the front of 6FC5370-4AM20-0AA0 meet IP65?The front flap must be closed; the rear remains IP20 / UL open type.
-
Which temperature limits apply to 6FC5370-4AM20-0AA0?Front operation is 0 to +45 °C; rear operation is 0 to +55 °C. Condensation and icing are excluded.
-
Does the hardware order code of 6FC5370-4AM20-0AA0 define all CNC software options?No. Software execution, licensed options and machine configuration must be matched separately.
-
Which backups should be retained for 6FC5370-4AM20-0AA0?Retain the approved CNC and PLC backups, machine data and peripheral-interface configuration before service.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.