Match the complete marking
Include 6XV1830-0EH10 200M and any hardware revision or assembly markings visible on the item. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered 6XV1830-0EH10 200M with the installed equipment and applicable Siemens documentation.
Technical specifications for 6XV1830-0EH10 200M
-
Manufacturer:Siemens
-
Product Category:General Automation
-
Spare Part Number:6XV1830-0EH10 200M
-
Weight:3.74 kg
-
Tariff Code:8537101190
-
Product series:SIMATIC NET
-
Cable type:PROFIBUS FC Standard Cable GP
-
Offered length:200 m
-
Conductors:2
-
Shield:Aluminum-clad foil and tin-plated copper braid
-
Outer sheath:Violet PVC
-
Nominal impedance:150 ohms at 3 to 20 MHz, ±10%
-
Maximum loop resistance:110 milliohms/m
-
Capacitance:28.5 pF/m at 1 kHz
-
Operating temperature:-40 to +75 °C
-
Tensile load:100 N maximum
Information
- The 200M marking describes the offered length and remains part of this listing identity; it does not define a permissible network segment length.
Product series: SIMATIC NET
Cable type: PROFIBUS FC Standard Cable GP
The cable has red and green polyethylene-insulated conductors, a PVC inner sheath and violet PVC outer sheath. Shielding combines overlapped aluminum-clad foil with a braid of tin-plated copper wire. Nominal characteristic impedance is 150 ohms in the 3 to 20 MHz range, with a ten-percent tolerance. Maximum loop resistance is 110 milliohms per metre and capacitance is 28.5 pF per metre at 1 kHz.
The operating, storage, transport and installation temperature range is minus 40 to plus 75 degrees Celsius. Minimum permissible bend radius is 37.5 mm for a single bend and 75 mm for repeated bends; maximum tensile load is 100 N. Use the correct connector and termination, maintain shield continuity and plan the bus topology and segment length for the actual data rate. The standard cable is intended for fixed installation rather than unrestricted continuous-flex motion.
-
Siemens 6XV1830-0EH10 200M technical reference
Apter Power technical reference - PDF, 5 pages. Verified product identity, technical characteristics and configuration context. -
Siemens 6XV1830-0EH10 200M installation guide
Prepared by Apter Power - PDF, 5 pages. Model identification, interface checks, configuration review and commissioning verification.
Application scope: Cable characteristics apply to manufacturer article 6XV1830-0EH10; 200M is the offered length. Bus segment limits depend on the configured network rate and topology.
-
Fixed PROFIBUS wiring
Install the standard two-wire cable in a permanent bus route suited to the network topology. -
FastConnect termination
Prepare compatible cable ends and terminate the conductors and screen with matching FC components. -
Cabinet bus distribution
Maintain shield continuity and the required bend and strain limits through the cabinet route. -
Segment extension
Engineer the segment length and termination for the actual bus rate before using the offered cable length.
Match 6XV1830-0EH10 and retain the offered 200M length identity.
Choose compatible FastConnect terminals and a bus topology appropriate to the configured data rate.
Preserve screen continuity, bend-radius limits and the maximum 100 N tensile load.
Check terminations, conductor assignment and communication across the completed segment.
Use the applicable isolation and electrostatic-discharge controls. Preserve connectors, identification and mechanical retention during handling.
Apply the approved site acceptance procedure and compare actual behavior with the recorded system configuration before returning equipment to service.
Alternative Names
Technical notes
System relationship: Choose compatible FastConnect terminals and a bus topology appropriate to the configured data rate.
Applicability: Cable characteristics apply to manufacturer article 6XV1830-0EH10; 200M is the offered length. Bus segment limits depend on the configured network rate and topology.
Technical reference: Siemens 6XV1830-0EH10 Product Data Sheet, 11/2026.
FAQ View All FAQ
-
What does 200M mean in 6XV1830-0EH10 200M?It identifies the offered 200 m length; the underlying manufacturer cable article is 6XV1830-0EH10.
-
How many conductors does 6XV1830-0EH10 200M contain?It contains two conductors with red and green insulation.
-
What shielding construction is used in 6XV1830-0EH10 200M?Overlapped aluminum-clad foil is combined with a braided screen of tin-plated copper wire.
-
What impedance applies to 6XV1830-0EH10 200M?Nominal characteristic impedance is 150 ohms from 3 to 20 MHz, with a ten-percent tolerance.
-
What temperature range is specified for 6XV1830-0EH10 200M?Operation, storage, transport and installation are specified from -40 to +75 °C.
-
What bend-radius limits apply to 6XV1830-0EH10 200M?The minimum is 37.5 mm for a single bend and 75 mm for multiple bends.
-
What maximum pulling load applies to 6XV1830-0EH10 200M?The maximum tensile load is 100 N.
-
Does the offered length of 6XV1830-0EH10 200M establish a permitted PROFIBUS segment length?No. Segment length and topology must be selected for the actual network rate, connectors and termination arrangement.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.