Match the complete marking
Include 6ES7412-2XJ05-0AB0 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered 6ES7412-2XJ05-0AB0 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6ES7412-2XJ05-0AB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7412-2XJ05-0AB0
-
Weight:0.7 kg
-
Tariff Code:8537101190
-
Product series:SIMATIC S7-400
-
CPU designation:CPU 412-2
-
Work memory:256 KB code + 256 KB data
-
Integrated load memory:512 KB RAM
-
Expandable load memory:FLASH or RAM card, up to 64 MB
-
First interface:MPI / PROFIBUS DP; up to 12 Mbit/s
-
Second interface:PROFIBUS DP; up to 12 Mbit/s
-
DP slaves, first / second interface:32 / 64 maximum; address limits apply
-
Total I/O address area:4 KB inputs / 4 KB outputs
-
5 V backplane current:0.9 A typical; 1.1 A maximum
-
Typical power loss:4.5 W
-
Typical bit-operation time:75 ns
-
Diagnostic buffer:400 entries maximum; configurable
-
Reference firmware:V5.3
Information
- Siemens 6ES7412-2XJ05-0AB0 coordinates the user program, rack I/O and distributed PROFIBUS stations within an engineered S7-400 system.
Product series: SIMATIC S7-400
Work memory: 256 KB code + 256 KB data
Integrated interfaces: MPI/DP and PROFIBUS DP
The CPU integrates two electrically isolated RS-485 interfaces. The first supports MPI or PROFIBUS DP and the second supports PROFIBUS DP, with transmission rates up to 12 Mbit/s. In DP master mode, the first interface supports up to 32 slaves and the second up to 64, subject to their separate address limits. The total I/O address area is 4 KB inputs and 4 KB outputs, and the process image can be configured within that capacity.
Typical execution times are 75 ns for bit, word and fixed-point operations and 225 ns for floating-point operations. A configurable diagnostic buffer supports up to 400 entries, helping maintenance teams correlate faults with CPU operation. The CPU draws typically 0.9 A and at most 1.1 A from the 5 V S7-400 backplane supply; typical power loss is 4.5 W. Expansion racks, communication processors and configured functions must be checked as a complete station rather than inferred from the CPU order number alone.
-
Siemens 6ES7412-2XJ05-0AB0 technical reference
Original Siemens excerpt - PDF, 7 pages. CPU memory, execution, diagnostics and selected electrical characteristics. -
Siemens 6ES7412-2XJ05-0AB0 installation guide
Prepared by Apter Power - PDF, 5 pages. Project, power, interface and functional acceptance checks.
Network compatibility: Check the separate MPI/DP and DP roles, address capacities and firmware. Ethernet or PROFINET connectivity requires the appropriate configured communication hardware.
-
Rack-based automation
Run the S7-400 program with the installed local and expansion I/O. Check code memory, data memory and station configuration before replacing the CPU. -
Distributed PROFIBUS control
Use the two DP-capable interfaces with their respective slave-count and address limits. Preserve bus termination, station addressing and data mapping. -
MPI operator communication
Use the first interface for supported programming and operator communication. Match baud rate, connection resources and the selected MPI or DP mode. -
Station diagnostics
Read the configurable diagnostic buffer and test variables during fault investigation. Retain the approved project and backup information before hardware changes.
Compare the complete 6ES7412-2XJ05-0AB0 marking and fitted firmware with the project. Do not substitute another CPU 412 execution solely by its family name.
Preserve the approved STEP 7 project, memory-card identity and current data. Battery-backed retention depends on the installed backup arrangement.
Allow for typical 0.9 A and maximum 1.1 A consumption from the 5 V backplane. Connected MPI/DP devices also load their interface supply.
The first DP interface supports up to 32 slaves and the second up to 64. Check their different address capacities and per-slave data limits.
The CPU has MPI/DP and DP interfaces. Do not assume integrated Ethernet or PROFINET; check any separately fitted communication processor.
Review diagnostic events, program startup, retained data and all affected I/O. Resolve discrepancies before restarting the process.
Alternative Names
Technical notes
System relationship: Check S7-400 rack compatibility, backplane loading, power-supply backup battery and the installed expansion configuration.
Configuration boundary: CPU 412-2 data applies to 6ES7412-2XJ05-0AB0 with the specified firmware; network limits depend on the selected interface and configuration.
Technical reference: Siemens S7-400 Automation System, CPU Specifications, A5E00850746-08, 04/2009.
FAQ View All FAQ
-
What CPU is Siemens 6ES7412-2XJ05-0AB0?It is the SIMATIC S7-400 CPU 412-2 with integrated MPI/DP and PROFIBUS DP interfaces.
-
How is work memory divided in 6ES7412-2XJ05-0AB0?The CPU provides 256 KB for program code and 256 KB for data. These are separate work-memory areas.
-
How can load memory be expanded on 6ES7412-2XJ05-0AB0?It includes 512 KB RAM load memory and supports FLASH or RAM memory cards up to 64 MB.
-
How many DP slaves can 6ES7412-2XJ05-0AB0 support?The first DP interface supports up to 32 slaves and the second up to 64. Interface address capacities and per-slave data limits also apply.
-
Does 6ES7412-2XJ05-0AB0 have an integrated Ethernet port?Its integrated interfaces are MPI/DP and PROFIBUS DP. Ethernet or PROFINET functions require appropriate separately configured communication hardware.
-
What backplane current does 6ES7412-2XJ05-0AB0 draw?Consumption from the 5 V S7-400 backplane is typically 0.9 A and at most 1.1 A. Interface-connected devices have separate supply-loading limits.
-
How does 6ES7412-2XJ05-0AB0 retain data after power loss?The referenced configuration uses battery-backed buffering. With a backup battery, work and load memory are retained; without battery buffering, those RAM data are not retained.
-
What diagnostic buffer is available in 6ES7412-2XJ05-0AB0?The buffer is configurable up to 400 entries, with 120 entries as the reference default. Review the fitted configuration when comparing event history.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.