Match the complete marking
Compare the complete 6ES7412-2XJ05-0AB0 marking, case and terminals with the installed unit.
-
Check the offered item before ordering
Request photos of the offered 6ES7412-2XJ05-0AB0 and confirm companion hardware and scope in the quotation.
Technical specifications for 6ES7412-2XJ05-0AB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7412-2XJ05-0AB0
-
Weight:0.7 kg
-
Tariff Code:8537101190
-
CPU designation:CPU 412-2
-
Work memory:256 KB code + 256 KB data
-
Integrated load memory:512 KB RAM
-
Expandable load memory:FLASH or RAM card, up to 64 MB
-
First interface:MPI / PROFIBUS DP; up to 12 Mbit/s
-
Second interface:PROFIBUS DP; up to 12 Mbit/s
-
DP slaves, first / second interface:32 / 64 maximum; address limits apply
-
Total I/O address area:4 KB inputs / 4 KB outputs
-
5 V backplane current:0.9 A typical; 1.1 A maximum
-
Typical power loss:4.5 W
-
Typical bit-operation time:75 ns
-
Diagnostic buffer:400 entries maximum; configurable
-
Reference firmware:V5.3
Information
- Siemens 6ES7412-2XJ05-0AB0 coordinates the user program, rack I/O and distributed PROFIBUS stations within an engineered S7-400 system.
Work memory: 256 KB code + 256 KB data
Integrated load memory: 512 KB RAM
The CPU integrates two electrically isolated RS-485 interfaces. The first supports MPI or PROFIBUS DP and the second supports PROFIBUS DP, with transmission rates up to 12 Mbit/s. In DP master mode, the first interface supports up to 32 slaves and the second up to 64, subject to their separate address limits. The total I/O address area is 4 KB inputs and 4 KB outputs, and the process image can be configured within that capacity.
Typical execution times are 75 ns for bit, word and fixed-point operations and 225 ns for floating-point operations. A configurable diagnostic buffer supports up to 400 entries, helping maintenance teams correlate faults with CPU operation. The CPU draws typically 0.9 A and at most 1.1 A from the 5 V S7-400 backplane supply; typical power loss is 4.5 W. Expansion racks, communication processors and configured functions must be checked as a complete station rather than inferred from the CPU order number alone.
6ES7412-2XJ05-0AB0 Original Manufacturer Technical Excerpt
Original manufacturer technical pages applicable to 6ES7412-2XJ05-0AB0. PDF · 4 pages.6ES7412-2XJ05-0AB0 Installation & Verification Guide
Apter Power field checks and acceptance record for 6ES7412-2XJ05-0AB0. PDF · 5 pages.
Application scope: Use the complete hardware and application identity when selecting a replacement or planning commissioning.
Compare the complete order marking.
Retain program, parameters and addresses.
Safely isolate controlled circuits.
Verify memory card and retention plan.
Confirm power and backplane seating.
Check RUN, bus diagnostics and I/O.
Alternative Names
Technical notes
System relationship: Check S7-400 rack compatibility, backplane loading, power-supply backup battery and the installed expansion configuration.
Configuration boundary: CPU 412-2 data applies to 6ES7412-2XJ05-0AB0 with the specified firmware; network limits depend on the selected interface and configuration.
Technical reference: Siemens S7-400 Automation System, CPU Specifications, A5E00850746-08, 04/2009.
FAQ View All FAQ
-
Why must code and data memory be checked separately on 6ES7412-2XJ05-0AB0?The reference CPU divides work memory into 256 KB code and 256 KB data. The project must fit both allocations.
-
When is an expansion card needed for 6ES7412-2XJ05-0AB0?Integrated load memory is 512 KB RAM; a compatible FLASH or RAM card can extend load memory up to the documented 64 MB limit.
-
How should PROFIBUS loading be assessed for 6ES7412-2XJ05-0AB0?Check the configured slave counts and addressing against the first and second DP interface limits, including the published 32/64 maximums.
-
Does 6ES7412-2XJ05-0AB0 provide integrated Ethernet?Its documented interfaces are MPI/PROFIBUS DP and a second PROFIBUS DP path; Ethernet requires separate approved hardware.
-
Why is the rack power budget relevant to 6ES7412-2XJ05-0AB0?The CPU draws about 0.9 A typically and up to 1.1 A from the 5 V backplane. Include all modules in the supply calculation.
-
What must be preserved before a 6ES7412-2XJ05-0AB0 change?Save the project, memory-card contents, rack configuration, DP addresses and current diagnostic state.
-
How should 6ES7412-2XJ05-0AB0 be checked after power restoration?Confirm power and RUN state, inspect the diagnostic buffer and prove both fieldbus paths and representative I/O.
-
Can firmware be assumed identical for every 6ES7412-2XJ05-0AB0?No. The selected specifications reference V5.3; compare the installed firmware and project requirements before substitution.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-