Match the complete marking
Include 6DD1688-0AE2 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6DD1688-0AE2 with the installed equipment and applicable Siemens documentation.
Technical specifications for 6DD1688-0AE2
-
Manufacturer:Siemens
-
Product Category:DCS Systems
-
Spare Part Number:6DD1688-0AE2
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Product series:SIMADYN D
-
Product type:SS52 PROFIBUS DP Module
-
Network service:PROFIBUS DP
-
PROFIBUS role:Master or slave, configuration dependent
-
Carrier context:CS7
-
Network connector:X5 isolated RS-485
-
Service interface:RS-232 parameterization and diagnostics
Information
- Siemens 6DD1688-0AE2 is the SS52 communication module for SIMADYN D.
Plant integration: Exchange drive and process-control data
Configuration retention: Preserve network address and bus termination
The SS52 provides an isolated RS-485 PROFIBUS interface at X5 and a separate RS-232 connection for parameterization and diagnostics. Its PROFIBUS-DP functions include Shared Input, SYNC and FREEZE where supported by the configured system. The SS52 identification is important: the neighboring SS5 designation addresses a different PROFIBUS service and must not be treated as the same communication module.
SIMADYN D control installations use this communication path where drive, process or plant-control data must move between the controller and a PROFIBUS DP segment. Fit and configure the module only within the supported CS7 system arrangement. Preserve network address, bus termination and project parameters before replacement, then verify cyclic data and diagnostics after commissioning.
-
Siemens 6DD1688-0AE2 technical reference
Apter Power technical reference - PDF, 2 pages. Product identity, verified characteristics, system integration and selection checks. -
Siemens 6DD1688-0AE2 installation guide
Apter Power installation verification guide - PDF, 2 pages. Identity, host configuration, inspection and functional release checks.
Compatibility scope: The CS7 receptacle, HWConfig project and PROFIBUS role must match the installed SIMADYN D architecture. Connector X5 carries the isolated RS-485 bus interface; the SS52 is distinct from the SS5 FMS module.
-
Drive-control networking
Exchange configured command and status data between a SIMADYN D control arrangement and PROFIBUS DP devices. The exact data map is set by the project configuration. -
Distributed-device integration
Use the DP interface to link compatible field or automation devices into the SIMADYN D system. Master or slave operation follows the approved network design. -
SIMATIC system interface
A configured SS52 can participate in network architectures that require the supported DP or MPI function. Verify the implemented protocol and connected host before integration. -
Legacy communication repair
Restore an existing SS52/CS7 communication path with the same module and interface assignment. An SS5 FMS execution is a different communication type.
Confirm the full 6DD1688-0AE2 code and the CS7 receptacle used by the installed SS52. Record neighboring communication modules.
Make the SIMADYN D carrier and connected network safe under the site procedure. Avoid inserting or removing the module under power unless the approved procedure explicitly permits it.
Label the PROFIBUS cable and document connector type, termination state and shield arrangement. Protect the isolated RS-485 interface.
Retain the HWConfig selection, master/slave role, network address and exchanged data mapping. Use the service RS-232 interface only within the approved parameterization workflow.
Inspect the CS7 contacts and fit the SS52 into its intended receptacle without forcing the card. Use electrostatic-discharge controls.
Verify PROFIBUS diagnostics and data exchange with the connected control system. Resolve address or termination faults before returning control to service.
Alternative Names
Technical notes
System relationship: The SS52 provides an isolated RS-485 PROFIBUS interface at X5 and a separate RS-232 connection for parameterization and diagnostics. Its PROFIBUS-DP functions include Shared Input, SYNC and FREEZE where supported by the configured system. The SS52 identification is important: the neighboring SS5 designation addresses a different PROFIBUS service and must not be treated as the same communication module.
Applicability: The characteristics above describe the identified SIMADYN D execution of 6DD1688-0AE2. Optional functions, connected devices and installed revisions must be checked against the complete marking and approved project configuration.
Technical reference: Siemens SIMADYN D Hardware manual, SS52 communication module, 6DD1688-0AE2.
FAQ View All FAQ
-
What is the product type of Siemens 6DD1688-0AE2?Siemens 6DD1688-0AE2 is the SS52 communication module in the SIMADYN D system. It plugs into a CS7 carrier to provide the configured controller with a PROFIBUS-DP interface; it is not a stand-alone CPU or a PROFIBUS cable accessory.
-
What is the control platform of Siemens 6DD1688-0AE2?The module is specified for SIMADYN D. The CS7 carrier, its selected slot and the SS52 are configured in the system hardware project, so the replacement must match the installed SIMADYN D configuration rather than only the network connector.
-
What is the network service of Siemens 6DD1688-0AE2?Its documented network service is PROFIBUS-DP (SINEC L2-DP), including Shared Input, SYNC and FREEZE functions where configured. Siemens also lists MPI capability for SIMATIC S7/M7 communication; the required service must be checked against the actual project.
-
What is the PROFIBUS role of Siemens 6DD1688-0AE2?The SS52 can be configured as a PROFIBUS-DP master or slave. Its actual role, bus address and data exchange depend on the SIMADYN D hardware and network configuration; installing the same order number alone does not establish the correct role.
-
What is the carrier context of Siemens 6DD1688-0AE2?Siemens specifies the SS52 as a plug-in module for the CS7 carrier. Up to three communication modules can be fitted to a CS7, and data exchange with the CPU modules uses the carrier's 16 kbyte dual-port RAM; verify the selected slot in the project.
-
Which connector carries PROFIBUS on Siemens 6DD1688-0AE2?Connector X5 provides the electrically isolated RS-485 PROFIBUS interface. Siemens documents connection through a SINEC L2 bus connector or bus terminal; the bus termination and any drop-cable capacitance must suit the installed network and baud rate.
-
What should be preserved before replacing Siemens 6DD1688-0AE2?Record the complete order number and revision, CS7 slot, HWConfig assignment, master or slave role, bus address and cable termination. Preserve the approved configuration and wiring record so the replacement can be checked against the original network installation.
-
How is Siemens 6DD1688-0AE2 checked after installation?Confirm that the CS7 and SS52 are recognized in the configured slot, then check the PROFIBUS link and expected master/slave data exchange. Use the documented RS-232 parameterization and diagnostic interface where applicable, and test SYNC or FREEZE only if those functions are used in the project.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.