6DD1642-0BC0

Analog Output Module
In Stock
Ships by Monday, October 26
Fast Shipping Available

Product Describe:

Siemens 6DD1642-0BC0 is the EA12 analog output module for the SIMADYN D L-bus system. Its bipolar voltage outputs connect to plant signals through the SC12 cable and SU11 terminal interface, with front-panel test sockets for commissioning.

Ask our team:

Get a quick price for: 6DD1642-0BC0
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6DD1642-0BC0

Technical specifications for 6DD1642-0BC0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6DD1642-0BC0
  • Estimated shipping dimensions:
    2x26.1x26.1cm
  • Weight:
    0.38 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Module designation:
    EA12
  • System bus:
    SIMADYN D L bus
  • Analog output channels:
    8
  • Output voltage:
    -10 to +10 V
  • Maximum output current per channel:
    +/-10 mA
  • Recommended current at +/-10 V:
    +/-5 mA for noise suppression
  • Simultaneous channel load:
    8 outputs, each 10 mA
  • Output resolution:
    13 bits plus sign; approximately 1 mV
  • Output accuracy:
    14 bits; approximately 1 mV
  • Absolute linearity error:
    +/-0.6 mV
  • Differential linearity error:
    +/-1 mV
  • Monotonicity:
    14 bits; approximately 1 mV
  • Temperature dependency:
    Maximum 240 microV/C
  • Short-circuit protection to ground:
    56 ohm resistor
  • Permitted short-circuit duration:
    120 s
  • Output connector:
    X5, 20-pin
  • Front-panel measurement points:
    8 test-socket pairs
  • Terminal interface:
    SU11
  • Interface cable:
    SC12
  • Subrack slots occupied:
    1
  • +5 V supply range:
    +4.75 to +5.25 V
  • +5 V typical current drain:
    600 mA
  • +15 V supply range:
    +14.4 to +15.6 V
  • +15 V typical current drain:
    200 mA
  • -15 V supply range:
    -15.6 to -14.4 V
  • -15 V typical current drain:
    200 mA
  • Adjustment warm-up:
    Approximately 2 min
  • Cooling:
    Operation without fan possible
  • System air-intake temperature:
    0 to +55 C
  • System storage temperature:
    -25 to +70 C

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 6DD1642-0BC0 is the EA12 analog output module for the SIMADYN D L-bus system. Its bipolar voltage outputs connect to plant signals through the SC12 cable and SU11 terminal interface, with front-panel test sockets for commissioning.
  • Routes configured analog commands through the L-bus I/O system
  • Provides separate front-panel access for channel measurements
  • Allows channel-by-channel offset and gain adjustment
  • Uses a defined terminal-interface and screened-cable arrangement

EA12 connects X5 to SU11 through SC12; the output pins alternate with their associated grounds, while test sockets X11 to X18 correspond to channels 1 to 8. The screened plant wiring terminates at the cabinet screen rail rather than relying on the front panel alone.

Important Notice: EA12 outputs are not defined while system supply voltages rise. Keep the machine in a safe state during energization, and do not remove or insert the module under voltage.

Siemens 6DD1642-0BC0 Manuals & Downloads
Siemens 6DD1642-0BC0 Technical Reference (PDF)Siemens 6DD1642-0BC0 Manufacturer Manual Excerpt (PDF)

The technical reference covers EA12 output limits, channel wiring and calibration decisions. The manufacturer excerpt retains 28 unchanged original pages covering source identity, installation/EMC guidelines, system conditions and the complete EA12 section; it is not the full manual.

Analog command distribution
Carries the configured SIMADYN D voltage commands from the L-bus system to the connected plant interface.
Terminal-based signal wiring
Uses SC12 and SU11 to bring the module signals to screw/plug-in terminal connections without an additional SU11 signal conversion.
Channel commissioning
Allows measurement of the individual output signals at their corresponding front-panel test sockets during start-up.
Output calibration service
Supports checking and readjusting offset and gain for each output after the module reaches operating temperature.
Before work on Siemens 6DD1642-0BC0, identify the EA12 channel assignment, isolate the subrack and retain the SC12/SU11 signal and grounding arrangement.
1
Isolate the SIMADYN D supply before inserting or removing the EA12 module.
2
Keep the machine safe while power rises; analog output states are initially undefined.
3
Handle the board with grounded ESD protection and use conductive storage surfaces.
4
Secure the module tightly to the subrack before commissioning its outputs.
5
Check each X5 signal/ground pair against the assigned SU11 terminals.
6
Connect screened plant cables over a broad area to the cabinet screen rail.
7
Respect the channel load limit and the two-minute short-circuit duration.
8
Warm the module for about two minutes, check offset first, then check gain and the restored channel response.

Technical notes

Technical notes

Wire the X5 output/ground pairs through SC12 and SU11, and secure the module to the subrack for noise immunity. Allow about two minutes of warm-up before checking offset and gain; preserve the screened signal wiring and cabinet bonding arrangement.

FAQS

  • Why can an EA12 output be noisy even when its load is below 10 mA?
    The maximum channel load is not the preferred noise-suppression operating point. At +/-10 V, the recommended output current is +/-5 mA; switch-mode supply spikes on the ground cable can also require smoothing at the load input and a low-ohmic load.
  • Does the EA12 ground-fault protection permit a permanent short circuit?
    No. The output-to-ground protection uses a 56 ohm resistor and the permitted short-circuit duration is 120 seconds. Remove the fault rather than leaving the output shorted indefinitely.
  • When should offset be checked relative to gain?
    Allow approximately two minutes for the board to reach operating temperature. Check offset first with the configured output at 0.0 and measure 0 V; the subsequent gain check uses a configured value of 2.0 and a 10 V measurement. Use the channel's separate offset and gain potentiometers.
  • Which measurements belong to channel 8 at X5?
    Channel 8 uses X5 pin 15 for its output and pin 16 for ground. The matching front-panel test socket is X18 and the configuration designation is X5H; SU11 terminals 15 and 16 carry the same pair.
  • Does SU11 convert the EA12 voltage signals?
    SU11 provides direct terminal access without signal conversion. Connect it through SC12; this interface arrangement is distinct from terminal modules that adapt or convert other signal types.
  • Why is tightening the subrack mounting important for analog signal quality?
    Noise-immune EA12 operation requires the module to be tightly screwed into the subrack. Screen the plant-side signals and connect the screen over the largest practical surface area to the cabinet screen rail; front-panel contact alone does not replace that arrangement.
  • Can output drift be ignored after a large cabinet-temperature change?
    Offset and gain are adjusted near 20 C, and the output temperature dependency is specified as a maximum of approximately 240 microV per C. Check the channel at its actual operating temperature before deciding whether readjustment is needed.
  • Are configured output values guaranteed during supply ramp-up?
    No. SIMADYN D output states are undefined while the supply voltages rise. The machine design and commissioning sequence must prevent those start-up states from creating a hazardous condition.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.