6SL3200-0SP01-0AA0

Siemens SINAMICS CIM PM-IF Assembly for PM240 FSGX
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

6SL3200-0SP01-0AA0 is a Siemens SINAMICS CIM PM-IF spare assembly for the PM240 Power Module in frame size FSGX. The assembly combines the CIB, power-supply board and mounting plate for the documented power-module interface position.

Ask our team:

Get a quick price for: 6SL3200-0SP01-0AA0
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6SL3200-0SP01-0AA0

Technical specifications for 6SL3200-0SP01-0AA0

  • Manufacturer:
    Siemens
  • Product Category:
    Server Driver
  • Spare Part Number:
    6SL3200-0SP01-0AA0
  • Estimated shipping dimensions:
    19.8x7.2x4.5cm
  • Weight:
    0.5 kg
  • Tariff Code:
    85049090
  • Counliy of origin:
    Germany
  • Product family:
    SINAMICS
  • Assembly designation:
    CIM PM-IF
  • Assigned Power Module:
    PM240
  • Assigned frame size:
    FSGX
  • Lifecycle:
    Product cancellation

Information

Information

Overview Manuals Common Applications Product Precautions
6SL3200-0SP01-0AA0 restores the CIM PM-IF electronics and mechanical carrier position inside a PM240 FSGX Power Module.
  • Combines the named CIB interface component
  • Includes the documented power-supply board
  • Uses the supplied mounting plate as the service carrier
  • Matches the PM240 frame-size FSGX spare-part position

The spare assembly is treated as one documented service set containing the CIB, power-supply board and mounting plate. Work is limited to the PM240 FSGX host and requires controlled isolation, connection restoration and post-service diagnostics.

Important Notice: Confirm 6SL3200-0SP01-0AA0, CIM PM-IF, PM240 FSGX host, installed hardware version, CIB and power-supply connections, optical and terminal wiring, mounting plate, grounding, firmware, drive configuration and staged diagnostic results before commissioning.

Apter Power 6SL3200-0SP01-0AA0 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

PM240 FSGX interface restoration
Replaces the documented CIM PM-IF assembly as one controlled service set.
Power-module electronics overhaul
Preserves the CIB and power-supply-board relationship during planned cabinet maintenance.
FSGX drive cabinet repair
Provides the official spare identity for the matching PM240 frame-size execution.
Post-fault interface validation
Supports staged reconnection and diagnostic review after an electronics-module exchange.
Read the applicable Siemens installation instructions before work. Verify 6SL3200-0SP01-0AA0, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the full 6SL3200-0SP01-0AA0 article number and CIM PM-IF designation.
2
Verify the installed host is a SINAMICS PM240 in frame size FSGX.
3
Isolate incoming power and prove the DC link discharged before cabinet access.
4
Record CIB, power-supply, terminal and optical connections before removal.
5
Keep the mounting plate, fasteners and insulation arrangement with the approved assembly.
6
Use ESD-safe handling for the CIB and power-supply-board electronics.
7
Restore the approved drive configuration without changing unrelated parameters.
8
Complete recognition, power-supply and PM240 diagnostic checks before enabling the motor.

Alternative Names

Alternative Names

6SL32000SP010AA0

Technical notes

Technical notes

Install 6SL3200-0SP01-0AA0 only in the matching PM240 FSGX power module and retain the documented CIB, power-supply and mounting-plate relationship. Record every electrical and optical connection before removal, then verify recognition and power-module diagnostics after controlled energization.

FAQS

  • What is included in the documented 6SL3200-0SP01-0AA0 spare assembly?
    Siemens lists the CIB, power-supply board and mounting plate as the assembly components.
  • Which Power Module receives 6SL3200-0SP01-0AA0?
    The exact assignment is a SINAMICS PM240 Power Module in frame size FSGX.
  • Which connections should be recorded before removing 6SL3200-0SP01-0AA0?
    Record the CIB, power-supply, terminal, signal and optical connections present in the installed FSGX module.
  • Is 6SL3200-0SP01-0AA0 a stand-alone converter?
    No. It is a spare electronics and mounting assembly for a specific PM240 FSGX host.
  • What should be isolated before work on 6SL3200-0SP01-0AA0?
    Isolate incoming power and prove the PM240 DC link discharged before opening the power module.
  • How should 6SL3200-0SP01-0AA0 configuration be handled?
    Retain the approved PM240 project and firmware relationship; do not change unrelated drive parameters during the hardware exchange.
  • Which diagnostics confirm 6SL3200-0SP01-0AA0 installation?
    Verify assembly recognition, electronics supply, interface health and the PM240 diagnostic state before enabling the motor.
  • What identity must be retained when replacing 6SL3200-0SP01-0AA0?
    Keep the complete article number, FSGX host identity, board and mounting-plate records, connection map and removed-part record.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.