Technical specifications for FRN1420A
-
Manufacturer:Motorola
-
Product Category:General Automation
-
Spare Part Number:FRN1420A
-
Weight:0.54 kg
-
Tariff Code:8537101190
-
Exact catalog identity:16 discrete input module for MOSCAD
-
Input purpose:Dry-contact status sensing in 16DI family
-
Counter capability:Two dedicated high-speed inputs in 16DI family
-
Low-speed count:Application-controlled use of digital inputs in 16DI family
-
Event recording:Time tagging in 16DI family
-
Isolation:Optically isolated input paths in 16DI family
-
Module connection:Plugs into MOSCAD RTU motherboard
-
Field wiring:Removable front connectors in 16DI family
-
Status indication:Input and module diagnostics in 16DI family
Information
- FRN1420A adds field-contact state collection to a compatible Motorola MOSCAD RTU.
Point schedule: preserve channel-to-contact map
Event setup: verify application options
Field proof: exercise every used input
The related 16DI module design supports status indication, isolation and counter or time-tag functions under appropriate RTU configuration. The product sheet uses FRN1420 as the field-installed base code, so the A-suffix unit should be checked against its own marking and terminal layout before transferring any precise wiring or counter setup.
For replacement, preserve the contact schedule, common wiring, event logic and RTU program. After fitting the module, prove each channel from the actual field device through the RTU point database and verify alarms or sequence-of-event records.
-
Motorola FRN1420A technical reference
Prepared by Apter Power - PDF, 4 pages. Motorola MOSCAD 16DI Digital Input Module specification, R3-11-83; Motorola 2005 U.S. Price Book, FRN1420A entry. -
Motorola FRN1420A installation guide
Prepared by Apter Power - PDF, 3 pages. Model-specific installation, electrical checks and commissioning review.
Family boundary: Counter and time-tag functions belong to the related 16DI architecture; verify the installed A-suffix execution and software mapping before enabling them.
-
Equipment status
Map switches or relay contacts to the RTU point database for operating-state monitoring. -
Alarm detection
Use contact changes as application inputs for approved alarm or interlock logic. -
Event history
Where the RTU configuration supports it, record time-tagged input changes for sequence review. -
Pulse count duties
Apply supported counter channels only after confirming the exact A-suffix module and field pulse characteristics.
De-energize the RTU and isolate field circuits before removing the module.
Compare the A-suffix label, connector layout and motherboard position with the installed unit.
Verify each field device presents the specified contact interface rather than an unapproved powered signal.
Trace input commons and removable terminal blocks before moving conductors.
Preserve channel mapping, alarm rules and counter/time-tag options in the RTU program.
Exercise every used contact, observe local indication and verify the corresponding host point and event behavior.
Alternative Names
Technical notes
A-suffix identity: FRN1420A is the exact catalog code. Confirm its physical revision and terminal arrangement before applying base FRN1420 wiring details.
Signal type: The 16DI family senses contact closure states; it does not source an analog measurement or drive an output load.
Technical reference: Motorola 2005 U.S. Price Book identifies FRN1420A; Motorola MOSCAD 16DI Digital Input Module specification, R3-11-83, describes the related 16DI architecture.
FAQ View All FAQ
-
How should FRN1420A be matched to a MOSCAD RTU slot?Compare the exact A-suffix marking, motherboard position, terminal-block style and installed RTU configuration before moving the module.
-
What signal should be connected to FRN1420A inputs?The catalog identifies a discrete-input module and the related 16DI architecture uses dry-contact closures. Check the exact unit wiring before applying field power.
-
Why can an FRN1420A input LED change without a host alarm?The physical contact can be seen by the module while the RTU point map, scan or application logic is wrong. Trace the point from terminal through CPU to the alarm rule.
-
How should shared commons be handled when replacing FRN1420A?Document each conductor and common return by terminal; transfer the block only after the A-suffix connector assignment is verified.
-
When may FRN1420A be used for pulse counting?The related 16DI platform supports counter functions, but the exact A-suffix hardware and RTU program must be checked against pulse rate and channel wiring first.
-
How does time tagging on FRN1420A depend on the RTU?Event time meaning comes from the related 16DI module capability together with CPU and application setup. Confirm clock synchronization and recorded event sequence in the installed system.
-
How can a stuck input on FRN1420A be isolated?Test the field contact and common path, then compare local indication with the CPU point state to separate wiring, module and program faults.
-
What verifies FRN1420A after replacement?Operate each used field contact and confirm the matching RTU point, alarm or counter event; record the channel-by-channel result against the original schedule.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.