Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 3502E
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3502E

  • Manufacturer:
    Invensys
  • Product Category:
    DCS Systems
  • Spare Part Number:
    3502E
  • Estimated shipping dimensions:
    20.3x12.7x5.1cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Module type:
    TMR digital input with circuit stuck-On self-test
  • Nominal input:
    48 VAC/VDC
  • Input points:
    32, commoned in groups of 8
  • Input frequency:
    DC or 47-63 Hz
  • Recommended input range:
    35-95 VAC/VDC
  • Maximum voltage:
    95 VAC/VDC
  • Off-to-On level:
    27 VAC/VDC typical; 32 VAC/VDC worst-case
  • On-to-Off level:
    14 VAC/VDC typical; 11 VAC/VDC worst-case
  • Nominal turn-on current:
    6-9 mA
  • Input impedance:
    > 2.9 kOhm nominal
  • Input delay:
    Off-to-On < 8 ms; On-to-Off < 15 ms
  • Point isolation:
    1,000 VAC minimum; 1,500 VDC minimum
  • Logic power:
    < 10 W
  • Status indication:
    One indicator per point; PASS, FAULT and ACTIVE module indicators
  • Slot keys:
    Top 004; bottom 005
  • Maintenance toggle:
    Normally Off points: every 24 months, under approved procedure

Information

Overview Manuals Common Applications Product Precautions
The Invensys Triconex 3502E monitors discrete field states across three independent input channels before the Main Processors vote the resulting data. Its documented diagnostics, hot-spare support and mechanical keying are intended for controlled Tricon v9-v11 service.
  • 32 points commoned in groups of eight
  • 48 VAC/VDC nominal TMR input architecture
  • Continuous circuit stuck-On self-test
  • PASS, FAULT, ACTIVE and per-point indicators

Each channel independently conditions and scans every 3502E input point, then sends its table to the corresponding Main Processor. The Main Processors vote the input data before the application uses it.

The module requires a matched external termination panel and interface cabling. Mechanical slot keying uses top key 004 and bottom key 005, and the official guide lists field-point toggling for normally Off points at the documented maintenance interval.

Important Notice: Confirm the complete 3502E identity, slot keys, ETP, interface cables, field-voltage range and approved maintenance record before installation or replacement.

Invensys Triconex 3502E Manuals & Downloads
Invensys Triconex 3502E Technical Reference (PDF)Invensys Triconex 3502E Installation & Commissioning Guide (PDF)

These two documents are different: the first consolidates exact-model electrical, diagnostic and slot-key data; the second provides controlled installation, commissioning, testing and acceptance checks.

Emergency shutdown inputsAcquire approved 48 VAC/VDC discrete trip contacts in a fault-tolerant Tricon safety architecture.
Burner-management permissivesMonitor documented field switches that participate in approved burner safety logic.
Fire-and-gas discrete signalsBring approved alarm and trip contacts into a voted Tricon input path.
Critical machinery protectionMonitor documented discrete protective states where TMR input integrity is required.
For Invensys Triconex 3502E, verify exact identity, slot keying, field-voltage limits, ETP compatibility and maintenance records before work.
1Record the complete 3502E identity, chassis and logical slot.
2Apply the approved safe-work procedure and isolate field energy.
3Verify top key 004 and bottom key 005 before insertion.
4Confirm the ETP, both interface cables and group commoning.
5Check every field point against the 35-95 VAC/VDC input range.
6Account for the documented diagnostic-glitch behavior in parallel circuits.
7Verify point indicators plus PASS, FAULT and ACTIVE status.
8Complete the approved functional test and maintenance record before release.

Technical notes

The self-test checks the ability to detect the transition of a normally energized circuit to the Off state. The official guide warns that a diagnostic glitch can appear on an adjacent de-energized point, so parallel equipment inputs and commissioning tests must account for the documented behavior.

FAQ View All FAQ

  • What is Invensys Triconex 3502E?
    It is a 32-point, 48 VAC/VDC TMR digital-input module with a circuit stuck-On self-test.
  • How are Invensys Triconex 3502E points grouped?
    The 32 input points are commoned in four groups of eight.
  • What input range is recommended for Invensys Triconex 3502E?
    The manufacturer table lists 35-95 VAC/VDC with a 95 VAC/VDC maximum.
  • How does Invensys Triconex 3502E process input data?
    Three independent channels condition and scan the points, and the Main Processors vote the resulting input tables.
  • Which indicators are present on Invensys Triconex 3502E?
    Each point has an On/Off indicator and the module has PASS, FAULT and ACTIVE indicators.
  • Can Invensys Triconex 3502E be maintained as a hot spare?
    The official guide states that Tricon digital-input modules include the hot-spare feature for controlled online replacement.
  • Which slot keys belong to Invensys Triconex 3502E?
    The official slot-key table lists top key 004 and bottom key 005.
  • Which Invensys Triconex 3502E points require periodic toggling?
    The guide lists normally Off points for field-point toggling every 24 months under the approved maintenance procedure.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.