T9802

AADvance Dual Digital Input Termination Assembly
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

ICS Triplex T9802 is an AADvance dual digital input termination assembly for 16 isolated channels. It connects two T9401 or T9402 digital input modules to protected field terminations.

Ask our team:

Get a quick price for: T9802
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for T9802

Technical specifications for T9802

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC Systems
  • Spare Part Number:
    T9802
  • Estimated shipping dimensions:
    13x4x4.5cm
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Termination function:
    Digital input
  • Redundancy arrangement:
    Dual
  • Field connections:
    16
  • Supported modules:
    Two T9401 or T9402
  • Conductor size:
    1.31 mm2 maximum (16 AWG)
  • Strip length:
    6 mm
  • Channel fuse:
    50 mA, 125 V, Type T
  • Channel load:
    5.125 kohm +/-0.2%
  • Input resolution:
    5 mV, 13 bit
  • Channel isolation:
    +/-1.5 kVdc maximum for 1 minute
  • Loop dissipation:
    0.2 W maximum per field loop
  • Assembly weight class:
    260 g dual TA allowance

Information

Information

Overview Manuals Common Applications Product Precautions
T9802 is the field termination and protection interface for a dual AADvance digital-input group. It keeps the two participating input modules connected to a common set of isolated field channels.
  • Terminates sixteen isolated digital input field circuits
  • Supports a dual arrangement of matching AADvance input modules
  • Provides replaceable channel fuses accessible at the termination assembly
  • Maintains engineered conductor and isolation interfaces at the cabinet boundary

The termination assembly mates with the AADvance base-unit and the dual digital-input module positions defined in the hardware configuration. Replacement validation includes fuse condition, terminal torque, channel-to-variable mapping, dual-module health and field fault detection.

Important Notice: Verify the complete T9802 identity, AADvance base-unit position, dual T9401/T9402 module type, 16-channel terminal map, fuse ratings, conductor preparation, isolation boundaries, Workbench configuration and channel diagnostics before commissioning.

Apter Power T9802 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

Dual safety input groups
Terminates paired AADvance input modules used for redundant field-state acquisition.
Protected switch input panels
Provides individual fuse protection and field landing points for discrete switch circuits.
Line-monitored input assemblies
Supports field-state and fault detection when used with the configured digital input modules.
AADvance cabinet expansion
Adds a standardized dual digital-input termination position to an approved I/O base-unit row.
Read the applicable ICS Triplex installation instructions before work. Verify T9802, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the T9802 marking and dual digital-input group assignment.
2
Isolate all 16 field circuits before touching the termination assembly.
3
Record terminal numbers, polarity and cable identifiers before disconnection.
4
Inspect each 50 mA Type T channel fuse and use only the specified replacement.
5
Prepare conductors to the documented cross-section and strip length.
6
Confirm two matching T9401 or T9402 modules occupy the configured positions.
7
Restore the AADvance hardware configuration without mixing module channel counts.
8
Test every field state, line fault and dual-module diagnostic before release.

Technical notes

Technical notes

Mount T9802 on the approved AADvance I/O base-unit arrangement and pair it only with two matching T9401 or T9402 digital input modules. Verify all 16 field terminals, channel fuses, conductor preparation and isolated-channel assignments before applying field voltage.

FAQS

  • What is the exact system role of T9802?
    It is the 16-channel dual digital-input termination assembly for an AADvance controller.
  • Which host, rack or carrier is required for T9802?
    Install it in the approved T9300 I/O base-unit arrangement with two compatible T9401 or T9402 digital input modules.
  • What wiring or connector checks apply to T9802?
    Use the documented 16 field terminals, 1.31 mm2 maximum conductors, 6 mm strip length and the specified channel fuse type.
  • How is T9802 configured for service?
    Its physical module grouping and corresponding Workbench hardware configuration must both identify a dual digital-input arrangement.
  • Which diagnostics should be reviewed for T9802?
    Review both input-module health states, channel state and voltage data, line faults and individual fuse-related field faults.
  • What must be preserved when replacing T9802?
    Preserve the terminal map, polarity, fuse set, base-unit position, paired module types and application variable mapping.
  • How should T9802 be commissioned after installation?
    Energize field circuits in a controlled sequence and verify all 16 states, fault indications and dual-channel behavior.
  • What model-specific limitation must be checked for T9802?
    Do not mix 8-channel and 16-channel input modules within one dual or triple termination arrangement.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.