Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for TC-HAO081
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for TC-HAO081

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    TC-HAO081
  • Estimated shipping dimensions:
    3.5x14x14.5cm
  • Weight:
    0.24 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output points:
    8
  • Signal function:
    HART analog output
  • Module family:
    CIOM-A

Information

Overview Manuals Common Applications Product Precautions
Honeywell TC-HAO081 is an eight-point CIOM-A HART analog output module. It sends analog control signals and HART communication to smart final elements in a C200 system.
  • Generates HART-enabled analog commands
  • Carries analog commands and HART data
  • Fits a C200 I/O chassis
  • Interfaces smart final elements

TC-HAO081 installs with C200 I/O chassis, ControlNet I/O adapter, HART field wiring, Smart valve positioner in an engineered Experion C200 ControlNet I/O configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this eight-point hart analog output module.

Important Notice: Confirm the complete TC-HAO081 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power TC-HAO081 Manuals and Guides
Apter Power TC-HAO081 Product Technical Reference PDFHoneywell TC-HAO081 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
HART valve positioningGenerates HART-enabled analog commands
Smart actuator diagnosticsCarries analog commands and HART data
Drive reference controlFits a C200 I/O chassis
C200 output-loop modernizationInterfaces smart final elements
Read the applicable Honeywell installation instructions before work. Verify TC-HAO081 and the installed Experion C200 ControlNet I/O configuration.
1Verify the complete TC-HAO081 marking and the assigned Experion C200 ControlNet I/O position before field work.
2Isolate the applicable power, network and field energy before disconnecting TC-HAO081.
3Use ESD controls and protect the keyed connectors of TC-HAO081 during handling.
4Record the installed wiring, jumpers, node or channel assignment before replacement.
5Confirm C200 I/O chassis and ControlNet I/O adapter against the approved system configuration.
6Restore TC-HAO081 under controlled conditions and review the product-specific diagnostics.
7Complete a functional test for hart valve positioning before production release.

Technical notes

Secure the process output, preserve channel polarity and HART addressing, then test analog stroke and digital device communication independently.

FAQ View All FAQ

  • How should ControlNet I/O adapter be isolated before disconnecting the TC-HAO081 Eight-Point HART Analog Output Module?
    Place the affected process in its approved maintenance state, isolate applicable energy and prove ControlNet I/O adapter safe before disconnection.
  • What as-found wiring record is required for the TC-HAO081 Eight-Point HART Analog Output Module in HART valve positioning?
    Record terminal identity, polarity, shields, jumpers, cable tags and the as-found diagnostic state for TC-HAO081.
  • Which Experion C200 ControlNet I/O configuration must be checked when commissioning the TC-HAO081 Eight-Point HART Analog Output Module?
    Verify the assigned channel, slot, node or interface and compare it with the approved Experion C200 ControlNet I/O configuration before enabling TC-HAO081.
  • How can the TC-HAO081 Eight-Point HART Analog Output Module be function-tested for Smart actuator diagnostics without disturbing the process?
    Use a controlled stimulus or limited command, observe the expected system indication and confirm the intended response while normal interlocks remain effective.
  • Which diagnostics should be reviewed if the TC-HAO081 Eight-Point HART Analog Output Module stops performing its assigned system function?
    Check seating, the matched C200 I/O chassis, the condition of ControlNet I/O adapter and the model-specific diagnostics before replacing more hardware.
  • Can the TC-HAO081 Eight-Point HART Analog Output Module used for Drive reference control be transferred to another Experion C200 ControlNet I/O position without engineering review?
    No. Confirm the hardware execution, connector scheme and approved Experion C200 ControlNet I/O configuration before transferring TC-HAO081 to a different duty.
  • What evidence should be retained after the TC-HAO081 Eight-Point HART Analog Output Module returns to C200 output-loop modernization service?
    Retain the physical identification, as-left wiring or configuration, final diagnostics and controlled functional-test result for TC-HAO081.
  • Which C200 I/O chassis identity must be verified before fitting the TC-HAO081 Eight-Point HART Analog Output Module?
    Match the complete TC-HAO081 marking, assigned Experion C200 ControlNet I/O position and installed C200 I/O chassis before work.
Related reading

Related cases and sourcing guidance

View all case studies