PR6423-10R-010 operates with Reverse-mount probe bracket, PR6423-compatible converter, Conductive target, LEMO-connected monitoring input.
Engineered applications include Inside-out bearing bracket installations, Reverse-access shaft vibration, Thrust-collar position monitoring, Special machine retrofit points.
Important Notice: Confirm reverse-mount clearance and 3/8-24 UNF engagement, support the five-metre lead and verify probe polarity plus gap response after mechanical tightening.
The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Allows the PR6423 probe to be secured from the reverse side of the bracket.
Supports non-contact measurement where normal access is restricted.
Tracks axial movement with the documented two-millimetre span.
Provides a retrofit path for special probe-holder geometry.
Verify the complete PR6423-10R-010 order code, 3/8-24 UNF-2A reverse mount mounting interface and assigned PR6423 8 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6423-10R-010.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 5 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.