Technical specifications for MC-TAOY22 51204172-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51204172-175
  • Estimated shipping dimensions:
    30.6x12x5cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Assembly type:
    Analog output FTA
  • Signal family:
    Analog output
  • Field termination:
    Compression-terminal arrangement
  • System family:
    Honeywell process I/O

Information

Overview Manuals Common Applications Product Precautions
Honeywell MC-TAOY22 51204172-175 is a field termination assembly for analog-output wiring.
  • Analog-output field termination
  • Command-signal marshalling
  • Cabinet-side field routing
  • System-specific terminal integration

MC-TAOY22 provides the field-termination interface for compatible analog-output channels. Confirm the assigned signal range, channel scaling, loop continuity, field-device wiring and approved terminal connections, then verify each commanded output under controlled conditions.

Important Notice: Confirm whether the matching I/O module, terminal assembly, cable set, field wiring and cabinet accessories required for MC-TAOY22 51204172-175 are included in the quotation or stock description.

Apter Power MC-TAOY22 Manuals and Guides

Important Notice: These are two separate Apter Power documents prepared from product-specific Honeywell technical information. Confirm the physical nameplate, current Honeywell documents and installed-system requirements before configuration or installation. They do not replace Honeywell manuals.

MC-TAOY22 installed-base replacement
Supports like-for-like maintenance of the documented analog output field termination assembly.
MC-TAOY22 compatibility review
Checks the host hardware, slot or mounting position, companion assembly, cable and revision before replacement.
MC-TAOY22 installation planning
Defines the required isolation, ESD, terminal, wiring and configuration checks before field work.
MC-TAOY22 commissioning
Supports controlled power, channel, communication, diagnostic and process-response checks after installation.
Read the applicable Honeywell instructions before work. Verify model MC-TAOY22, part number 51204172-175 and the installed-system configuration.
1
Verify model MC-TAOY22 and part number 51204172-175 on the physical label before use.
2
Use MC-TAOY22 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.
3
Match every MC-TAOY22 connector, terminal, cable and companion assembly before moving field wiring.
4
Back up the applicable controller, node, I/O or communication configuration before replacing MC-TAOY22.
5
Isolate energy before handling MC-TAOY22 unless the applicable hardware procedure explicitly permits energized service.
6
Follow ESD controls and protect MC-TAOY22 connectors and printed-circuit assemblies during handling.
7
Do not transfer channel, voltage, current, terminal or firmware values from a similar model to MC-TAOY22.
8
After installing MC-TAOY22, complete the relevant power, channel, link, diagnostic, alarm and fail-state checks.

Alternative Names

MC-TAOY22 51204172-175

Technical notes

Use MC-TAOY22 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.

FAQ View All FAQ

  • Which output service is MC-TAOY22 intended for?
    MC-TAOY22 is intended for analog output field termination assembly service with the channel and signal limits listed on this page.
  • How should an output load be matched to MC-TAOY22?
    Confirm the load voltage, current, resistance, field supply and protection are within the documented limits for MC-TAOY22.
  • What commissioning test is appropriate for MC-TAOY22?
    Exercise one MC-TAOY22 channel at a time under an approved test procedure and verify the field device, feedback and fail-state response.
  • What assembly type value applies to MC-TAOY22?
    For MC-TAOY22, the listed assembly type value is Analog output FTA. Confirm the same marking and configuration on the installed unit before work.
  • What signal family value applies to MC-TAOY22?
    For MC-TAOY22, the listed signal family value is Analog output. Confirm the same marking and configuration on the installed unit before work.
  • What field termination value applies to MC-TAOY22?
    For MC-TAOY22, the listed field termination value is Compression-terminal arrangement. Confirm the same marking and configuration on the installed unit before work.
  • What system family value applies to MC-TAOY22?
    For MC-TAOY22, the listed system family value is Honeywell process I/O. Confirm the same marking and configuration on the installed unit before work.
  • What system role is assigned to MC-TAOY22?
    MC-TAOY22 is used as the analog output field termination assembly described on this page; match that role to the installed Honeywell architecture.
  • Is MC-TAOY22 compatible with every Honeywell rack or chassis?
    No. Match MC-TAOY22 to the exact Honeywell host, rack or chassis, slot, companion hardware and project revision used by the installed system.
  • What installation checks are required for MC-TAOY22?
    Confirm isolation, ESD controls, slot or mounting position, connector orientation, terminal hardware, cable code and field wiring before installation.
  • Which fault information helps troubleshoot MC-TAOY22?
    Record MC-TAOY22 indicators, diagnostics, affected channels, field measurements, wiring checks, companion hardware and the sequence that produced the fault.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.