CC-PAIH01

High-Level Analog Input Module with HART
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Honeywell CC-PAIH01 is a high-level analog input module with hart for Experion Series-C I/O. It acquires high-level analog process values and HART device data for Experion Series-C control and asset diagnostics.

Ask our team:

Get a quick price for: CC-PAIH01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for CC-PAIH01

Technical specifications for CC-PAIH01

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    CC-PAIH01
  • Estimated shipping dimensions:
    15.8x5.7x14.6cm
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input type:
    Voltage or current; 2-wire or self-powered transmitters
  • Channels:
    16; 12 single-ended / 4 differential
  • Voltage-input channels:
    13 to 16
  • A/D resolution:
    16 bit
  • Ranges:
    0-5 V; 1-5 V; 0.4-2 V; 4-20 mA through 250 Ohm
  • CMRR:
    70 dB, dc to 60 Hz
  • Common-mode voltage:
    -6 to +5 V peak
  • NMRR:
    19 dB at 60 Hz
  • Input filter:
    Single pole; -3 dB at 6.5 Hz
  • Maximum differential input:
    +/-30 V
  • Crosstalk:
    -60 dB
  • Powered input impedance:
    >10 MOhm
  • Scan period:
    50 ms
  • Accuracy at 23.5 +/-2 degC:
    +/-0.075% FS
  • Accuracy at 0 to 60 degC:
    +/-0.15% FS
  • Compatible IOTAs:
    CC-TAIX01; CC-TAIX11 redundant

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell CC-PAIH01 is high-level analog input module with hart. It acquires high-level analog process values and HART device data for Experion Series-C control and asset diagnostics.
  • Processes sixteen high-level analog channels
  • Supports HART communication with connected field devices
  • Provides four differential voltage-input positions
  • Offers open-wire detection and loop diagnostics

CC-PAIH01 operates with CC-TAIX01 or redundant CC-TAIX11 IOTA, HART or conventional transmitters, Series-C carrier, Experion control and asset configuration.

Engineered applications include HART pressure-transmitter integration, Multivariable flow measurement, Process analog acquisition, Redundant analog-input renewal.

Important Notice: Confirm the CC-TAIX01/CC-TAIX11 arrangement, IOTA jumpers, voltage-channel allocation, loop power and HART device identity before scanning and diagnostics.

Apter Power CC-PAIH01 Manuals and Guides

Apter Power CC-PAIH01 Product and System Technical Reference PDFApter Power CC-PAIH01 Field Installation and Functional Acceptance Workbook PDF

The first document organizes model-specific identity, technical data and system context. The second provides a separate installation, connection, commissioning and acceptance workflow.

HART pressure-transmitter integration

Collects process variables and device-status data from HART transmitters.

Multivariable flow measurement

Brings multiple variables from supported field instruments into Experion.

Process analog acquisition

Conditions conventional voltage or current signals for control strategies.

Redundant analog-input renewal

Restores input hardware while retaining HART addressing and channel ranges.

Read the applicable Honeywell instructions before work. Verify CC-PAIH01 and the installed Experion Series-C I/O configuration.
1

Verify the complete CC-PAIH01 marking and its assigned HART high-level analog-input position before work.

2

Place the connected process and control strategy in the approved maintenance state.

3

Isolate the applicable cabinet supply and analog and HART field energy before disconnecting conductors.

4

Record terminal numbers, channel assignments, polarity, shields and configured ranges before removal.

5

Use ESD controls and protect the backplane connector, terminal hardware and coated electronics.

6

Confirm the installed CC-TAIX01 or CC-TAIX11 IOTA and carrier arrangement against the approved project.

7

Restore power in a controlled sequence and clear only diagnostics created by the maintenance activity.

8

Complete analog scaling, open-wire and HART communication checks and retain the measured result before returning the channel to automatic service.

Technical notes

Technical notes

Confirm the CC-TAIX01/CC-TAIX11 arrangement, IOTA jumpers, voltage-channel allocation, loop power and HART device identity before scanning and diagnostics.

FAQS

  • What exact Honeywell system position is intended for CC-PAIH01?
    CC-PAIH01 is assigned to the documented Experion Series-C I/O role as high-level analog input module with hart; confirm that role against the installed cabinet record.
  • Which field signal or controlled function is handled by CC-PAIH01?
    Its documented signal duty is high-level analog current/voltage inputs plus hart digital communication. The controlling source lists channels as 16; 12 single-ended / 4 differential.
  • Which companion hardware must be checked before installing CC-PAIH01?
    Match CC-PAIH01 with CC-TAIX01 or redundant CC-TAIX11 IOTA and HART or conventional transmitters; also retain the approved carrier, cable and project identity.
  • What electrical limit should an engineer verify before wiring CC-PAIH01?
    Verify the model-specific value for A/D resolution: 16 bit. Do not transfer a limit from another module revision.
  • How should the installed configuration be preserved when replacing CC-PAIH01?
    Record the as-found slot, connector, channel assignment and project revision, then restore only the approved Experion Series-C I/O configuration.
  • Which isolation or handling check applies to CC-PAIH01?
    Apply the isolation and ESD sequence stated for CC-PAIH01; the source also identifies cmrr as 70 dB, dc to 60 Hz.
  • What diagnostic or commissioning evidence is required for CC-PAIH01?
    Complete the model-specific functional check for hart pressure-transmitter integration, review host diagnostics and retain the final test result.
  • Can CC-PAIH01 be substituted for a visually similar Honeywell assembly?
    No automatic substitution is assumed. Compare the complete CC-PAIH01 marking, input type, companion hardware, signal duty and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.