Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for TK-ORC161
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for TK-ORC161

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    TK-ORC161
  • Estimated shipping dimensions:
    3.5x14x14.5cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Isolated relay output module
  • I/O family:
    Honeywell Series A
  • Output channels:
    16
  • Contact form:
    Normally open
  • Documented output class:
    24-220 V AC
  • Terminal-block pins:
    36
  • Module width:
    Single-wide
  • Execution:
    Coated TK-series model
  • Host:
    Documented Series A chassis and terminal block
  • Commissioning scope:
    Slot identity, terminal block, load supply, normal state and controlled relay response

Information

Overview Manuals Common Applications Product Precautions
Honeywell TK-ORC161 provides isolated switching of sixteen normally-open AC relay outputs in a documented Honeywell Series A I/O installation.
  • Sixteen normally-open relay outputs
  • Isolated 24-220 VAC output class
  • Single-wide Series A module
  • Coated TK execution

The component remains matched to its documented host position, field connections and approved engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm TK-ORC161, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

Honeywell TK-ORC161 Manuals & Downloads

These documents are different: the first consolidates verified product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

Series A relay output
Switches documented AC loads from an Experion Series A chassis.
Discrete actuator command
Provides normally-open relay contacts for compatible field devices.
Coated control cabinet
Uses the TK execution in the documented industrial environment.
Output-module replacement
Restores slot, terminal block, channel mapping and relay-state verification.
Read the applicable Honeywell installation instructions before work. Verify TK-ORC161, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm TK-ORC161 on the coated Series A module record.
2
Place all sixteen output loads in the approved maintenance state.
3
Record the slot, terminal-block identity, load supply and normal state of every channel.
4
Isolate chassis and field energy before module removal.
5
Verify the 36-pin terminal block and connector condition.
6
Restore channel mapping and normally-open relay assignments.
7
Review chassis, module and channel diagnostics.
8
Exercise each assigned relay with field energy controlled before release.

Alternative Names

TK-ORC161

Technical notes

Install TK-ORC161 only in the documented Honeywell Series A I/O position and preserve its exact wiring, interfaces and configuration. After controlled energization, verify diagnostics and isolated switching of sixteen normally-open AC relay outputs before release.

FAQ View All FAQ

  • What output function does TK-ORC161 provide?
    It provides isolated relay digital outputs.
  • How many output channels are provided by TK-ORC161?
    It provides sixteen output channels.
  • Which contact form is documented for TK-ORC161?
    The outputs use normally-open contacts.
  • Which output-voltage class is documented for TK-ORC161?
    The documented output class is 24-220 V AC.
  • How many terminal-block pins are associated with TK-ORC161?
    The documented terminal block has 36 pins.
  • What chassis width does TK-ORC161 occupy?
    It is a single-wide Series A module.
  • What does the TK prefix indicate for TK-ORC161?
    It identifies the coated execution in the Series A family.
  • Which test releases TK-ORC161 after replacement?
    Exercise every assigned relay while confirming terminal mapping, field supply and module diagnostics.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.