Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

TK-ORC161

TK-ORC161 Isolated Relay Output Module
In Stock
Ships by Wednesday, October 7
Fast Shipping Available

Product Describe:

Honeywell TK-ORC161 is a coated Series A isolated relay-output module with sixteen normally-open channels. It is used for documented 24-220 VAC output service in an Experion Series A chassis.

Ask our team:

Get a quick price for: TK-ORC161
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TK-ORC161

Technical specifications for TK-ORC161

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    TK-ORC161
  • Estimated shipping dimensions:
    3.5x14x14.5cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Isolated relay output module
  • I/O family:
    Honeywell Series A
  • Output channels:
    16
  • Contact form:
    Normally open
  • Documented output class:
    24-220 V AC
  • Terminal-block pins:
    36
  • Module width:
    Single-wide
  • Execution:
    Coated TK-series model
  • Host:
    Documented Series A chassis and terminal block
  • Commissioning scope:
    Slot identity, terminal block, load supply, normal state and controlled relay response

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell TK-ORC161 provides isolated switching of sixteen normally-open AC relay outputs in a documented Honeywell Series A I/O installation.
  • Sixteen normally-open relay outputs
  • Isolated 24-220 VAC output class
  • Single-wide Series A module
  • Coated TK execution

The component remains matched to its documented host position, field connections and approved engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm TK-ORC161, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

Honeywell TK-ORC161 Manuals & Downloads

These documents are different: the first consolidates verified product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

Series A relay output
Switches documented AC loads from an Experion Series A chassis.
Discrete actuator command
Provides normally-open relay contacts for compatible field devices.
Coated control cabinet
Uses the TK execution in the documented industrial environment.
Output-module replacement
Restores slot, terminal block, channel mapping and relay-state verification.
Read the applicable Honeywell installation instructions before work. Verify TK-ORC161, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm TK-ORC161 on the coated Series A module record.
2
Place all sixteen output loads in the approved maintenance state.
3
Record the slot, terminal-block identity, load supply and normal state of every channel.
4
Isolate chassis and field energy before module removal.
5
Verify the 36-pin terminal block and connector condition.
6
Restore channel mapping and normally-open relay assignments.
7
Review chassis, module and channel diagnostics.
8
Exercise each assigned relay with field energy controlled before release.

Alternative Names

Alternative Names

TK-ORC161

Technical notes

Technical notes

Install TK-ORC161 only in the documented Honeywell Series A I/O position and preserve its exact wiring, interfaces and configuration. After controlled energization, verify diagnostics and isolated switching of sixteen normally-open AC relay outputs before release.

FAQS

  • What output function does TK-ORC161 provide?
    It provides isolated relay digital outputs.
  • How many output channels are provided by TK-ORC161?
    It provides sixteen output channels.
  • Which contact form is documented for TK-ORC161?
    The outputs use normally-open contacts.
  • Which output-voltage class is documented for TK-ORC161?
    The documented output class is 24-220 V AC.
  • How many terminal-block pins are associated with TK-ORC161?
    The documented terminal block has 36 pins.
  • What chassis width does TK-ORC161 occupy?
    It is a single-wide Series A module.
  • What does the TK prefix indicate for TK-ORC161?
    It identifies the coated execution in the Series A family.
  • Which test releases TK-ORC161 after replacement?
    Exercise every assigned relay while confirming terminal mapping, field supply and module diagnostics.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.