8C-TAIMA1 51307171-175

Temperature Input IOTA
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell 8C-TAIMA1 51307171-175 is the 8C-TAIMA1 Thermocouple/RTD IOTA used for field termination for thermocouple and RTD temperature inputs in a documented Honeywell Experion Series 8 I/O installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: 8C-TAIMA1 51307171-175
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 8C-TAIMA1 51307171-175

Technical specifications for 8C-TAIMA1 51307171-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51307171-175
  • Estimated shipping dimensions:
    22x12x6cm
  • Weight:
    0.34 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Thermocouple/RTD I/O Termination Assembly
  • Input family:
    Thermocouple and RTD
  • Channels:
    16 isolated input positions
  • Execution:
    Coated
  • Associated IOM:
    8C-PAIMA1
  • Installation family:
    Experion Series 8 I/O

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell 8C-TAIMA1 51307171-175 is the 8C-TAIMA1 Thermocouple/RTD IOTA used for field termination for thermocouple and RTD temperature inputs in a documented Honeywell Experion Series 8 I/O installation.
  • Input family: Thermocouple and RTD
  • Channels: 16 isolated input positions
  • Execution: Coated
  • Associated IOM: 8C-PAIMA1

The component remains matched to its installed host, interface hardware and engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm 8C-TAIMA1 51307171-175, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

8C-TAIMA1 51307171-175 Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

8C-TAIMA1 Thermocouple/RTD IOTA
Honeywell 8C-TAIMA1 51307171-175 is the 8C-TAIMA1 Thermocouple/RTD IOTA used for field termination for thermocouple and RTD temperature inputs in a documented Honeywell Experion Series 8 I/O installation.
Installed-system maintenance
Preserves the documented slot, termination, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and reviews diagnostics.
Acceptance verification
Confirms the intended channel, network or safety function before release.
Read the applicable Honeywell installation instructions before work. Verify 8C-TAIMA1 51307171-175, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete 8C-TAIMA1 51307171-175 identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled test of field termination for analog input channels before release.

Alternative Names

Alternative Names

51307171-175

Technical notes

Technical notes

Install 8C-TAIMA1 51307171-175 only in its documented Honeywell Experion Series 8 I/O position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and field termination for thermocouple and RTD temperature inputs under controlled conditions.

FAQS

  • Which sensors connect to 8C-TAIMA1 51307171-175?
    It provides the field termination for thermocouple and RTD inputs.
  • How many temperature-input positions are associated with 8C-TAIMA1 51307171-175?
    The matched Series 8 arrangement provides sixteen isolated input positions.
  • Which I/O module pairs with 8C-TAIMA1 51307171-175?
    It pairs with the 8C-PAIMA1 temperature-input IOM.
  • Is 8C-TAIMA1 51307171-175 coated?
    Yes. The 8C execution is coated.
  • Why must sensor type be recorded before replacing 8C-TAIMA1 51307171-175?
    Each channel's TC or RTD selection, range and wiring determine the correct measurement path.
  • Which wiring details matter most on 8C-TAIMA1 51307171-175?
    Record channel assignment, sensor type, polarity or lead arrangement, shield and cold-junction context.
  • Can a current-input IOTA be substituted for 8C-TAIMA1 51307171-175?
    No. The IOTA must match the thermocouple/RTD IOM and its terminal architecture.
  • What should the commissioning record show for 8C-TAIMA1 51307171-175?
    It should show stable reference checks on every assigned temperature channel and clear module diagnostics.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat