Speak to a sourcing specialist
sales13@apterpower.com

8C-TAIDB1 51307133-175

Redundant AI IOTA
In Stock
Ships by Thursday, November 26
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell 8C-TAIDB1 is the coated redundant IOTA for the 16-channel 8C-PAIH54 differential analog input module. It supports current or voltage transmitters and single-ended or differential channel configuration within Series 8 I/O.
Get a quick price for 8C-TAIDB1 51307133-175
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 8C-TAIDB1 51307133-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51307133-175
  • Estimated shipping dimensions:
    29.5x12x7.5cm
  • Weight:
    0.38 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • IOTA role:
    Redundant differential analog input termination assembly
  • Compatible I/O module:
    8C-PAIH54
  • Input channels:
    16 single-ended or differential channels
  • Input type:
    Voltage or current; 2-wire or self-powered transmitters
  • Input ranges:
    0-5 V, 1-5 V, 0.4-2 V and 4-20 mA through 250 ohms
  • A/D resolution:
    16 bits
  • Voltage rating:
    24 VDC
  • Module current rating:
    310 mA
  • Input scan rate:
    50 ms
  • Normal-mode rejection:
    19 dB at 60 Hz
  • Common-mode rejection:
    70 dB, dc to 60 Hz with 500-ohm source imbalance
  • Input impedance:
    Greater than 10 Mohm for powered voltage inputs
  • Powered insertion/removal:
    Supported
  • Field power conditioning:
    Individually protected current-limiting circuits; no fuse required

Information

Overview Manuals Common Applications Product Precautions
Honeywell 8C-TAIDB1 is the coated redundant IOTA for the 16-channel 8C-PAIH54 differential analog input module. It supports current or voltage transmitters and single-ended or differential channel configuration within Series 8 I/O.
  • Redundant coated IOTA for 8C-PAIH54
  • Sixteen voltage or current input channels
  • Single-ended or differential channel operation
  • HART-capable analog input architecture

Use 8C-TAIDB1 with the documented 8C-PAIH54 module and preserve the approved current or voltage wiring, 250-ohm jumper selections, HART configuration and redundant path.

Important Notice: Confirm the complete 8C-TAIDB1 and 51307133-175 marking, companion module, channel mode and jumper record before commissioning.

Honeywell 8C-TAIDB1 Manuals & Downloads
Honeywell 8C-TAIDB1 Technical Reference (PDF)Honeywell 8C-TAIDB1 Installation & Commissioning Guide (PDF)

The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Differential transmitter input
Terminates approved differential current or voltage transmitter signals for the 8C-PAIH54 module.
Redundant analog acquisition
Provides the documented redundant IOTA path for high-availability Series 8 analog input service.
HART instrument integration
Supports HART-capable multivariable instruments through the compatible analog input module.
Mixed current-voltage loops
Allows documented current and voltage channels when each IOTA jumper and software range is configured correctly.
Read the applicable Honeywell instructions before work. Verify Honeywell 8C-TAIDB1 and the installed system configuration before commissioning.
1
Verify the complete 8C-TAIDB1 and 51307133-175 marking before work.
2
Confirm the companion module is the documented Honeywell 8C-PAIH54.
3
Place both redundant paths and the associated process loops in the approved maintenance state.
4
Record whether every channel is single-ended or differential before disturbing wiring.
5
Record every current or voltage range and the corresponding 250-ohm IOTA jumper state.
6
Preserve field conductors, shields, commons and HART device assignments exactly.
7
Use approved ESD controls and inspect the IOTA, connectors and redundant interfaces.
8
Verify all sixteen channels, diagnostics, HART communication and redundancy transfer before release.

Technical notes

Use 8C-TAIDB1 only with the documented 8C-PAIH54 analog input module and the approved channel wiring. Record every current or voltage selection, IOTA jumper state, HART assignment and redundancy path before controlled commissioning.

FAQ View All FAQ

  • Which I/O module is specified for Honeywell 8C-TAIDB1?
    Honeywell specifies 8C-TAIDB1 as the redundant coated IOTA for the 8C-PAIH54 analog input module.
  • How many channels does Honeywell 8C-TAIDB1 support?
    The documented 8C-PAIH54 and 8C-TAIDB1 arrangement supports sixteen channels configured as single-ended or differential inputs.
  • Which signal types can Honeywell 8C-TAIDB1 terminate?
    The documented arrangement accepts voltage or current inputs from 2-wire or self-powered transmitters.
  • Which ranges are documented for Honeywell 8C-TAIDB1?
    The official specification lists 0-5 V, 1-5 V, 0.4-2 V and 4-20 mA through 250 ohms.
  • What resolution and scan rate apply to Honeywell 8C-TAIDB1?
    The compatible analog input module uses 16-bit conversion and a 50 ms input scan rate.
  • Why must Honeywell 8C-TAIDB1 jumper positions be recorded?
    Each voltage channel requires its 250-ohm load resistor connection to be handled according to the IOTA jumper instruction, so the physical state must match the configured range.
  • Can Honeywell 8C-TAIDB1 be inserted or removed under power?
    The official specification states that module removal and insertion under power is supported, subject to the site's approved maintenance procedure.
  • What proves Honeywell 8C-TAIDB1 commissioning is complete?
    All sixteen ranges, wiring assignments, diagnostics and HART devices must agree with the approved record, and the redundant path transfer must pass its controlled test.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.