Match the complete marking
Include 51304386-150 MC-PPIX02 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 51304386-150 MC-PPIX02 with the installed equipment and applicable Honeywell documentation.
Technical specifications for 51304386-150 MC-PPIX02
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:51304386-150 MC-PPIX02
-
Weight:0.7 kg
-
Tariff Code:8537101190
-
Channels:8
-
Coating:Conformal-coated MC design
-
Signal forms:Rectangular or sine wave; pulse voltage or contact
-
Sensor arrangement:Self-powered 2-wire or system-powered 3-wire
-
Input impedance:10 kohm minimum
-
Frequency range:1 Hz–20 kHz; waveform, filter and cable conditions apply
-
Low input level:-0.5 to +1.9 V
-
High input level:+3.5 to +24 V
-
Field-input scan:20 ms
-
Accumulated-value update:20 ms
-
PV update:500 ms for 8 channels
-
Rate accuracy:±0.01% of frequency or ±0.4 Hz, whichever is larger
-
Rate resolution:±0.4 Hz
-
No-damage input limit:±30 V maximum
Information
- Pulse-rate and accumulated-value processing with 51304386-150 MC-PPIX02 depends on retaining the matched FTA, waveform and filter configuration.
Signal handling: Rectangular or sine-wave inputs with FTA restrictions
Processing: 20 ms input scan and 500 ms PV update for eight channels
The design has eight inputs with at least 10 kohm input impedance. Its specified range extends from 1 Hz to 20 kHz under the stated waveform, amplitude, filter and cable conditions. Square-wave low and high levels are -0.5 to +1.9 V and +3.5 to +24 V respectively. Sine waves must not be mixed with square waves or contacts on the same FTA; mixed amplitudes and longer FTA cables reduce the permitted maximum frequency.
Field-input and accumulated-value updates are 20 ms, while the process-variable update is 500 ms for eight channels. Rate accuracy is the larger of ±0.01% of input frequency or ±0.4 Hz, with ±0.4 Hz resolution. Minimum dwell depends on the filter selection: 25 microseconds at 20 kHz in storage position, 50 microseconds at 10 kHz in H, and 500 microseconds at 1 kHz in L. Preserve the installed filter, FTA, transmitter-power and cable configuration.
-
Honeywell 51304386-150 MC-PPIX02 technical reference
Original Honeywell excerpt - PDF, 3 pages, 12.1 KB. Part 51304386-150 identifies MC-PPIX02. The stated pulse-input ratings describe the paired processor/FTA design; the MC variant adds conformal coating. Waveform, filter and cable conditions remain applicable. -
Honeywell 51304386-150 MC-PPIX02 installation planning guide
Prepared by Apter Power - PDF, 5 pages, 97 KB. Identity, configuration, connection and controlled acceptance planning.
Platform applications: The following applications describe TPS Process Manager I/O functions. Match the complete 51304386-150 MC-PPIX02 identity to the installed system before selecting a replacement.
-
Pulse rate measurement
Acquire supported pulse signals within the waveform, amplitude, cable and filter limits. -
Accumulated-value processing
Use the 20 ms accumulated-value update in the configured totalizer application. -
Contact sensing
Use the appropriate contact-input FTA configuration and verify its electrical conditions. -
Conditioned transmitter integration
Match two-wire or three-wire sensing and the FTA power arrangement before applying field signals.
Retain 51304386-150 MC-PPIX02 and the installed processor/FTA configuration.
Do not mix sine-wave inputs with square waves or contacts on the same FTA.
Check FTA cable length and signal amplitude before applying the 20 kHz upper range.
Preserve the installed filter selection and corresponding minimum dwell requirement.
Verify signal levels, transmitter power and input protection limits before connection.
Use controlled signals to verify channel rate, accumulated value and configured alarms.
Alternative Names
Technical notes
Installation relationship: The design has eight inputs with at least 10 kohm input impedance. Its specified range extends from 1 Hz to 20 kHz under the stated waveform, amplitude, filter and cable conditions. Square-wave low and high levels are -0.5 to +1.9 V and +3.5 to +24 V respectively. Sine waves must not be mixed with square waves or contacts on the same FTA; mixed amplitudes and longer FTA cables reduce the permitted maximum frequency.
Configuration: Part 51304386-150 identifies MC-PPIX02. The stated pulse-input ratings describe the paired processor/FTA design; the MC variant adds conformal coating. Waveform, filter and cable conditions remain applicable.
Technical reference: Honeywell TPS Process Manager I/O Specification and Technical Data, IO03-500, November 1997; HPM Planning, HP02-500, Release 530 Revision 05.
FAQ View All FAQ
-
How many channels does 51304386-150 MC-PPIX02 provide?The pulse-input design provides eight channels. MC identifies the conformally coated processor version.
-
Which sensor arrangements can be used with 51304386-150 MC-PPIX02?The matched processor/FTA arrangement supports self-powered two-wire and system-powered three-wire sensors, with pulse-voltage or contact inputs.
-
What conditions limit the frequency range of 51304386-150 MC-PPIX02?The 1 Hz to 20 kHz range depends on waveform, amplitude, filter setting and FTA cable length. Mixed-amplitude signals over a 50 m FTA cable are limited to 9 kHz in the specified arrangement.
-
Can sine waves and contacts be mixed on the FTA used with 51304386-150 MC-PPIX02?No. Sine waves must not be intermixed with square waves or contacts on the same FTA.
-
Which pulse levels apply to the design of 51304386-150 MC-PPIX02?The specified low range is -0.5 to +1.9 V and the high range is +3.5 to +24 V; hysteresis separates the switching bands.
-
What update rates apply to 51304386-150 MC-PPIX02?Field-input and accumulated-value updates are 20 ms. The process-variable update is 500 ms for eight channels.
-
What rate accuracy applies to 51304386-150 MC-PPIX02?Use ±0.01% of input frequency or ±0.4 Hz, whichever is larger. The stated rate resolution is ±0.4 Hz.
-
How does filter selection affect dwell requirements for 51304386-150 MC-PPIX02?Minimum on/off dwell is 25 microseconds at 20 kHz with the filter jumper stored, 50 microseconds at 10 kHz in H, or 500 microseconds at 1 kHz in L.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.