Get a quick price for IS200VCRCH1BBB
For more information on how your data is processed and stored by Apterpower please read our privacy policy
-
Match the complete marking
Match IS200VCRCH1BBB, revision and visible labels.
-
Check the offered item before ordering
Confirm GE Mark VI turbine control, companion hardware and wiring.
Technical specifications for IS200VCRCH1BBB
-
Manufacturer:General Electric
-
Spare Part Number:IS200VCRCH1BBB
-
Weight:0.32 kg
-
Tariff Code:8537101190
-
Contact inputs:48 with external 24 V DC excitation
-
Relay outputs:12 Form-C dry contacts
-
Terminal-board relationship:TBCI/TICI input and TRLY relay families as configured
-
Processor scan:Mark VI I/O processing
-
Rack interface:VME backplane
-
Redundancy:Simplex or TMR by project architecture
-
Status indicators:RUN, FAIL and STATUS
Information
Overview
Downloads
Applications / Compatibility
Product Precautions
- IS200VCRCH1BBB combines forty-eight contact-input paths with twelve relay-output commands in the Mark VI VME control architecture.
Mixed discrete processing: One VME card handles large contact-input groups and controlled relay-output commands.
Architecture-dependent voting: Simplex and TMR installations use different processor and terminal-board relationships.
Connector-aware diagnostics: Board IDs and cable locations help distinguish configuration mismatch from field faults.
Architecture-dependent voting: Simplex and TMR installations use different processor and terminal-board relationships.
Connector-aware diagnostics: Board IDs and cable locations help distinguish configuration mismatch from field faults.
IS200VCRCH1BBB is a VCRC-family Mark VI discrete input/output board. The manual assigns contact-input and relay-output processing to the VCCC/VCRC architecture; the final suffix remains a revision identifier.
Input operation depends on excitation and terminal-board grouping, while relay output behavior depends on the fitted TRLY execution and project voting. Channel count alone is not enough for substitution.
Before exchange, export I/O configuration and record rack slot, terminal boards, cables and active states. After fitting, verify board recognition, representative contacts, relay commands, feedback and TMR agreement where used.
Input operation depends on excitation and terminal-board grouping, while relay output behavior depends on the fitted TRLY execution and project voting. Channel count alone is not enough for substitution.
Before exchange, export I/O configuration and record rack slot, terminal boards, cables and active states. After fitting, verify board recognition, representative contacts, relay commands, feedback and TMR agreement where used.
Controller platform reference: GE Mark VI turbine control. Follow applicable GE instructions and the approved site drawing.
The board reference covers mixed discrete architecture; the guide separates input-state validation from relay-output proof.
IS200VCRCH1BBB Technical Data Reference
GE Mark VI Turbine Control System Guide GEH-6421M; selected exact-model and documented family data for IS200VCRCH1BBB.IS200VCRCH1BBB Installation & Verification Guide
Model-specific installation, wiring, inspection and commissioning checks for IS200VCRCH1BBB.
Use the two files to commission contact acquisition and commanded relay action as different functions.
System and supply context: Discrete-control context: The board processes turbine permissives and alarm contacts while commanding approved relay-output circuits.
Application scope: Architecture compatibility: Cable fanout, terminal-board identity and configured voting must match the installed rack; a visual board match does not establish signal equivalence.
Application scope: Architecture compatibility: Cable fanout, terminal-board identity and configured voting must match the installed rack; a visual board match does not establish signal equivalence.
Turbine permissive inputs
Acquire breaker, valve and auxiliary-contact states.Alarm and trip relay control
Command documented relay outputs through the fitted terminal board.TMR discrete voting
Process redundant contact and output paths in approved architectures.Mark VI rack maintenance
Restore board, cable and terminal-board identity.
Prepare GE IS200VCRCH1BBB for its configured installation using these product-specific checks.
Export I/O assignments
Retain every input and relay mapping.
Record the terminal boards
Capture TBCI/TICI/TRLY execution.
Control relay power
Isolate customer-powered contacts before work.
Preserve cable location
Label JR, JS, JT or rack connections.
Test inputs separately
Verify excitation and state.
Test outputs under permit
Confirm command, contact and process feedback.
Alternative Names
GE IS200VCRCH1BBB
Discrete Input and Relay Output VME Board IS200VCRCH1BBB
Technical notes
Input-group baseline: Record normal contact states, wetting paths and voting expectations for the forty-eight inputs.
Relay-circuit isolation: Identify customer power, contact form, suppression and final-device feedback for each used output.
Mixed-I/O validation: Test representative input groups and all affected relay channels while comparing controller diagnostics.
FAQ View All FAQ
-
Which field interfaces must be documented for IS200VCRCH1BBB?Record the contact-input terminal board, relay-output terminal board, all rack cables and their connector locations.
-
How are the 48 inputs of IS200VCRCH1BBB energized?The Mark VI overview specifies external 24 V DC excitation; field grouping must follow the installed terminal-board design.
-
What output form is associated with IS200VCRCH1BBB?The architecture supports twelve Form-C dry-contact relay outputs through the documented relay terminal board.
-
Why can a VCCC card not be assumed equivalent to IS200VCRCH1BBB?They share functions but may differ in revision, compatibility and project configuration.
-
How should TMR disagreement involving IS200VCRCH1BBB be investigated?Compare R, S and T inputs, cables, terminal-board ID and configured voting before replacing field devices.
-
What relay test is appropriate after fitting IS200VCRCH1BBB?Use an approved output command and confirm coil or contact feedback and the intended process response.
-
Which status indications should be stable on IS200VCRCH1BBB?RUN should show normal operation, FAIL should remain clear and STATUS should have no unresolved diagnostic alarm.
-
Which contact-input and relay-output results confirm IS200VCRCH1BBB?Retain representative input-state and voting results, tested relay contact transfer, clear diagnostics and expected final-device feedback.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Related reading
Related cases and sourcing guidance
View all case studies
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.