Technical specifications for IC670MDL330
-
Manufacturer:General Electric
-
Product Category:PLC Systems
-
Spare Part Number:IC670MDL330
-
Estimated shipping dimensions:5.5x8.6x8.2cm
-
Weight:0.22 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Output points:16; one group
-
Rated voltage:12 to 120 V AC
-
Output-voltage range:10 to 132 V AC; 47 to 63 Hz
-
Maximum point current:1 A
-
Maximum module current:4 A with derating
-
Minimum load current:10 mA per point
-
Inrush current:10 A maximum for one 20 ms cycle
-
Output-voltage drop:2.0 V maximum
-
Leakage current:Less than 2 mA at 120 V AC
-
On/off response:Less than one-half cycle
-
BIU current:275 mA with all points on
-
Isolation:250 V AC continuous; 1500 V AC for 1 minute
Information
- Provides sixteen 12-120 VAC outputs
- Switches up to 1 A per point
- Limits total module load to 4 A with derating
- Reports group fuse status to the BIU
IC670MDL330 operates with 10 to 132 V AC field supply, Sixteen AC loads, Field Control terminal block, Compatible BIU or MFP.
Engineered applications include grouped AC actuator and pilot-load switching field station, Remote I/O cabinet integration, Installed-base module renewal, Controlled commissioning and diagnostics.
Important Notice: Confirm load current, 4 A module derating, leakage compatibility and snubber behavior; test fuse diagnostics before enabling automatic commands.
Apter Power IC670MDL330 Manuals and Guides
Apter Power IC670MDL330 Technical Data and System Reference PDFIC670MDL330 Field Installation and Commissioning Workbook PDFThe first document presents model-specific technical data and system identity. The second provides a separate installation, wiring and commissioning workflow.
grouped AC actuator and pilot-load switching field station
Performs the documented grouped ac actuator and pilot-load switching function at a distributed Field Control station.
Remote I/O cabinet integration
Exchanges configured process data with the host through the installed bus interface.
Installed-base module renewal
Restores an exact catalog-number position while preserving terminal and data identity.
Controlled commissioning and diagnostics
Supports staged wiring, configuration, diagnostic and functional verification.
Verify the complete IC670MDL330 catalog marking and assigned Field Control position before work.
Place the connected grouped AC actuator and pilot-load switching process in its approved maintenance state before disturbing the station.
Isolate BIU and field power, then confirm a safe condition at the IC670MDL330 terminal block.
Label and record individual point conductors, group commons and field-power feeds before disconnecting any conductor from IC670MDL330.
Use ESD controls and protect the module connector, terminal block keying and exposed electronics.
Restore only the documented input/output defaults, data reference and fault reporting; do not copy settings from an adjacent module.
Energize in a controlled sequence and review PWR, channel, module and network diagnostics.
Complete point-by-point state, response-time and diagnostic checks and retain the final result before returning the process to service.
Technical notes
FAQ View All FAQ
-
What Field Control function is assigned to IC670MDL330?IC670MDL330 is ge fanuc sixteen-point 12-120 vac one-amp discrete output module. It switches sixteen AC loads from one grouped field supply and returns output and fuse diagnostic status to the station interface.
-
Which station hardware must be paired with IC670MDL330?Use IC670MDL330 with the documented Field Control terminal block, compatible BIU or MFP, and the installed 10 to 132 v ac field supply.
-
Which IC670MDL330 identity should be checked before installation?Confirm the full IC670MDL330 catalog marking and the catalog number value IC670MDL330 against the installed station record.
-
How should field wiring be transferred when replacing IC670MDL330?Label and record individual point conductors, group commons and field-power feeds before disconnecting any conductor from IC670MDL330.
-
Which configuration item is critical when commissioning IC670MDL330?Restore only the documented input/output defaults, data reference and fault reporting; do not copy settings from an adjacent module.
-
What diagnostic checks apply to IC670MDL330?Energize in a controlled sequence and review PWR, channel, module and network diagnostics.
-
How should the IC670MDL330 signal path be functionally tested?Complete point-by-point state, response-time and diagnostic checks and retain the final result before returning the process to service.
-
Can IC670MDL330 be replaced by a visually similar Field Control module?No direct substitution should be assumed. Match IC670MDL330, its terminal assignment, data allocation, signal type, power arrangement, and the documented isolation value 250 V AC continuous; 1500 V AC for 1 minute before migration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.