Speak to a sourcing specialist
sales13@apterpower.com

IC670MDL241

GE Fanuc sixteen-point 240 VAC grouped discrete input module
In Stock
Ships by Thursday, November 12
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IC670MDL241 is ge fanuc sixteen-point 240 vac grouped discrete input module. It senses sixteen grouped 240 VAC field states and transfers the filtered input data to the Field Control station interface.
Get a quick price for IC670MDL241
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for IC670MDL241

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC670MDL241
  • Estimated shipping dimensions:
    5.5x8.6x8.2cm
  • Weight:
    0.22 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input points:
    16
  • Input grouping:
    Single group
  • Rated voltage:
    240 V AC
  • Input-voltage range:
    0 to 265 V AC; 47 to 63 Hz
  • Typical input current:
    8.2 mA per point at 240 V AC
  • Input impedance at 60 Hz:
    38.5 kohm
  • Input impedance at 50 Hz:
    46.3 kohm
  • On-state voltage:
    155 to 265 V AC
  • Off-state voltage:
    0 to 40 V AC
  • On-state current:
    4 to 10 mA
  • Off-state current:
    0 to 1.5 mA
  • On/off response:
    20 ms maximum

Information

Overview Manuals Common Applications Product Precautions
GE IC670MDL241 is ge fanuc sixteen-point 240 vac grouped discrete input module. It senses sixteen grouped 240 VAC field states and transfers the filtered input data to the Field Control station interface.
  • Provides sixteen 240 VAC inputs
  • Accepts 47-63 Hz field signals
  • Uses a single common input group
  • Limits on/off response to 20 ms maximum

IC670MDL241 operates with Sixteen 240 VAC field contacts, Single group common, Field Control terminal block, Compatible BIU or MFP.

Engineered applications include grouped 240 VAC discrete-state acquisition field station, Remote I/O cabinet integration, Installed-base module renewal, Controlled commissioning and diagnostics.

Important Notice: Isolate the 240 VAC source, verify the single group common and maintain required creepage and wiring practices before point-by-point testing.

Apter Power IC670MDL241 Manuals and Guides

Apter Power IC670MDL241 Technical Data and System Reference PDFIC670MDL241 Field Installation and Commissioning Workbook PDF

The first document presents model-specific technical data and system identity. The second provides a separate installation, wiring and commissioning workflow.

grouped 240 VAC discrete-state acquisition field station

Performs the documented grouped 240 vac discrete-state acquisition function at a distributed Field Control station.

Remote I/O cabinet integration

Exchanges configured process data with the host through the installed bus interface.

Installed-base module renewal

Restores an exact catalog-number position while preserving terminal and data identity.

Controlled commissioning and diagnostics

Supports staged wiring, configuration, diagnostic and functional verification.

Read the applicable GE Fanuc Field Control instructions before work. Verify IC670MDL241, its terminal assignment and the installed station configuration.
1

Verify the complete IC670MDL241 catalog marking and assigned Field Control position before work.

2

Place the connected grouped 240 VAC discrete-state acquisition process in its approved maintenance state before disturbing the station.

3

Isolate BIU and field power, then confirm a safe condition at the IC670MDL241 terminal block.

4

Label and record individual point conductors, group commons and field-power feeds before disconnecting any conductor from IC670MDL241.

5

Use ESD controls and protect the module connector, terminal block keying and exposed electronics.

6

Restore only the documented input/output defaults, data reference and fault reporting; do not copy settings from an adjacent module.

7

Energize in a controlled sequence and review PWR, channel, module and network diagnostics.

8

Complete point-by-point state, response-time and diagnostic checks and retain the final result before returning the process to service.

Technical notes

Isolate the 240 VAC source, verify the single group common and maintain required creepage and wiring practices before point-by-point testing.

FAQ View All FAQ

  • What Field Control function is assigned to IC670MDL241?
    IC670MDL241 is ge fanuc sixteen-point 240 vac grouped discrete input module. It senses sixteen grouped 240 VAC field states and transfers the filtered input data to the Field Control station interface.
  • Which station hardware must be paired with IC670MDL241?
    Use IC670MDL241 with the documented Field Control terminal block, compatible BIU or MFP, and the installed sixteen 240 vac field contacts.
  • Which IC670MDL241 identity should be checked before installation?
    Confirm the full IC670MDL241 catalog marking and the catalog number value IC670MDL241 against the installed station record.
  • How should field wiring be transferred when replacing IC670MDL241?
    Label and record individual point conductors, group commons and field-power feeds before disconnecting any conductor from IC670MDL241.
  • Which configuration item is critical when commissioning IC670MDL241?
    Restore only the documented input/output defaults, data reference and fault reporting; do not copy settings from an adjacent module.
  • What diagnostic checks apply to IC670MDL241?
    Energize in a controlled sequence and review PWR, channel, module and network diagnostics.
  • How should the IC670MDL241 signal path be functionally tested?
    Complete point-by-point state, response-time and diagnostic checks and retain the final result before returning the process to service.
  • Can IC670MDL241 be replaced by a visually similar Field Control module?
    No direct substitution should be assumed. Match IC670MDL241, its terminal assignment, data allocation, signal type, power arrangement, and the documented on/off response value 20 ms maximum before migration.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.