Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for IC660BBD120
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for IC660BBD120

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC660BBD120
  • Estimated shipping dimensions:
    8.5x10x22.2cm
  • Weight:
    1.4 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Counter inputs:
    12
  • Counter outputs:
    4
  • Counter configurations:
    Four Type A, two Type B or one Type C
  • Input voltage:
    5 to 30 VDC
  • Selectable input filters:
    2.5 us or 12.5 ms
  • Maximum count rate:
    200 kHz high range; 40 Hz low range
  • Input impedance:
    4 kohm
  • Logic supply:
    4.75 to 5.25 VDC, 200 mA
  • Output current:
    0.5 A per point; 2 A per block
  • Output inrush:
    3 A for 10 ms

Information

Overview Manuals Common Applications Product Precautions
IC660BBD120 provides the documented genius high-speed counter block role for a matched GE Genius I/O installation.
  • Provides the documented genius high-speed counter block function
  • Uses exact catalog identity IC660BBD120 for replacement control
  • Integrates with the matched GE Genius I/O hardware
  • Supports controlled connection checks and functional verification

The component is used with the exact terminal assembly, carrier, power grouping and bus configuration identified for IC660BBD120. Commissioning preserves the installed point map and verifies controlled field response.

Important Notice: Confirm IC660BBD120, GE Genius I/O host, hardware revision, terminal or connector type, power and signal ranges, wiring, grounding, bus configuration, companion accessories and controlled commissioning results before service release.

GE IC660BBD120 Manuals & Downloads

These are two different documents: the technical reference consolidates verified product and system data; the installation guide provides field checks, commissioning steps and acceptance records.

GE Genius I/O station maintenance
Restores the documented genius high-speed counter block function in an engineered station.
Distributed I/O refurbishment
Uses exact IC660BBD120 identity when rebuilding the recorded field interface.
Control-panel modernization
Preserves the approved terminal, power and communications arrangement during migration work.
Controlled recommissioning
Verifies point mapping, diagnostics and field response before process release.
Read the applicable General Electric installation instructions before work. Verify IC660BBD120, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the full IC660BBD120 catalog marking and installed GE Genius I/O position before work.
2
Isolate the station supply and connected field energy using the approved procedure.
3
Record every terminal, common, shield, connector and configured point before removal.
4
Use ESD controls and protect backplane, terminal and connector contacts from contamination.
5
Verify each documented value for IC660BBD120 against the installed host and field circuit.
6
Restore the approved terminal assembly, power grouping and configuration record.
7
Energize in the prescribed sequence and review module, bus and point diagnostics.
8
Complete a controlled signal or load test before returning the station to service.

Technical notes

Install IC660BBD120 only in the documented GE Genius I/O position. Preserve the as-found terminal mapping and configuration, then verify diagnostics and the affected field function under controlled conditions.

FAQ View All FAQ

  • How is IC660BBD120 identified?
    Match the complete catalog number and the Genius High-speed Counter Block designation.
  • Which system accepts IC660BBD120?
    Use the documented GE Genius I/O carrier, terminal and bus arrangement.
  • What records are retained before removing IC660BBD120?
    Record terminals, commons, shields, connectors, point mapping and diagnostics.
  • How is IC660BBD120 isolated safely?
    Isolate station and field supplies, prove the safe state and apply ESD controls.
  • Which official values govern IC660BBD120?
    Counter inputs: 12; Counter outputs: 4; Counter configurations: Four Type A, two Type B or one Type C; Input voltage: 5 to 30 VDC.
  • How is IC660BBD120 configuration restored?
    Restore the approved hardware execution, power grouping and point map.
  • Which diagnostics follow IC660BBD120 energization?
    Review module, bus and channel status in the prescribed startup sequence.
  • What releases IC660BBD120 to service?
    A controlled signal or load test with the expected field response and no active diagnostic.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.