Match the complete marking
Include KJ3243X1-BK1 SE4022 12P4691X042 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered KJ3243X1-BK1 SE4022 12P4691X042 with the installed equipment and applicable Emerson documentation.
Technical specifications for KJ3243X1-BK1 SE4022 12P4691X042
-
Manufacturer:Emerson
-
Product Category:DCS Systems
-
Spare Part Number:KJ3243X1-BK1 SE4022 12P4691X042
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Interface role:PROFIBUS DP I/O communication
-
DeltaV series:S-series
-
Catalog assembly reference:SE4022
-
Catalog assembly format:Simplex I/O interface with termination block
-
Fieldbus family:PROFIBUS DP
-
Card identity:KJ3243X1-BK1
-
Additional marking:12P4691X042
-
Host dependency:Compatible DeltaV controller, carrier and software configuration
Information
- KJ3243X1-BK1 SE4022 12P4691X042 provides a PROFIBUS DP interface for a configured DeltaV S-series control network.
Assembly reference: SE4022 simplex arrangement
Configuration focus: Preserve the installed segment and device mapping
SE4022 is the documented simplex PROFIBUS DP I/O interface assembly with a termination block. The complete KJ3243X1-BK1 and 12P4691X042 markings should be matched to the installed card and the associated termination hardware. A matching communication standard does not by itself establish revision or carrier interchangeability.
Before replacement, retain the bus address plan, segment wiring and device configuration. Verify the controller software release, intended network topology and termination arrangement, then compare module and device diagnostics when the segment returns to service.
-
Emerson KJ3243X1-BK1 SE4022 12P4691X042 technical reference
Apter Power technical reference - PDF, 2 pages. Product identity, verified characteristics, system role and engineering checks. -
Emerson KJ3243X1-BK1 SE4022 12P4691X042 installation verification guide
Apter Power installation guide - PDF, 1 page. Pre-installation, configuration, commissioning and acceptance checks.
Compatibility scope: Match the full KJ3243X1-BK1 SE4022 12P4691X042 marking, termination block, DeltaV host release and PROFIBUS DP address plan before substitution.
-
DeltaV PROFIBUS DP segment
Connect an approved PROFIBUS DP device segment to the configured DeltaV I/O subsystem. -
Distributed field I/O
Exchange cyclic process data with compatible remote I/O nodes whose device descriptions and mapping are installed in the control project. -
Drive communication
Integrate a PROFIBUS DP drive only when its profile, diagnostics and control-word mapping are supported by the project. -
Segment replacement
Restore the same interface role in a verified carrier and termination arrangement while preserving device addresses and configuration.
Read KJ3243X1-BK1, SE4022 and 12P4691X042 on the offered and installed hardware.
Capture each node address, device file and cyclic data map before changing the interface.
Check the installed termination block, cable shield and segment-end termination.
Isolate the affected system and use approved electrostatic-discharge handling.
Confirm the host release and downloaded device configuration before enabling the segment.
Check bus status and each required device diagnostic after recommissioning.
Alternative Names
Technical notes
Technical basis: Emerson DeltaV stock list, 121015, identifies SE4022 as a simplex PROFIBUS DP I/O interface with termination block; Emerson AMS Device Manager 12.0 Installation Guide describes S-series PROFIBUS DP system support.
Applicability: The SE4022 description is an Emerson assembly-level reference. Electrical and revision details for the complete offered markings are confirmed against the physical card and host configuration.
Integration focus: Preserve network addressing, termination and host configuration when planning an S-series PROFIBUS DP replacement.
FAQ View All FAQ
-
How should the PROFIBUS DP address plan be preserved when replacing KJ3243X1-BK1 SE4022 12P4691X042?Record the station addresses and device descriptions in the DeltaV project before removal; restore the approved configuration rather than accepting a default scan.
-
Can KJ3243X1-BK1 SE4022 12P4691X042 be exchanged with a different S-series interface solely because both use PROFIBUS DP?No. Match the card marking, carrier, termination block and supported host software before substitution.
-
What is the role of the termination block paired with KJ3243X1-BK1 SE4022 12P4691X042?It provides the field-side connection for the documented SE4022 simplex interface assembly. Confirm the actual part and wiring in the installed system.
-
What should be checked if a device remains offline after KJ3243X1-BK1 SE4022 12P4691X042 is fitted?Compare bus power, address, cable continuity, termination, device description and interface diagnostics with the pre-service record.
-
Does KJ3243X1-BK1 SE4022 12P4691X042 by itself define the permissible PROFIBUS cable length?No single cable limit for this complete marking has been established here. Segment length depends on baud rate, cable type, repeaters and the approved bus design.
-
How should a drive connected through KJ3243X1-BK1 SE4022 12P4691X042 be recommissioned?Compare profile selection, control and status word mapping, scaling and the required safe-state behavior with the original DeltaV configuration.
-
Can PROFIBUS PA devices be connected directly to KJ3243X1-BK1 SE4022 12P4691X042?The manufacturer describes PA use through an approved DP/PA coupler in supported system releases. Check the actual host release and coupler requirements.
-
What evidence should accompany a replacement request for KJ3243X1-BK1 SE4022 12P4691X042?Provide the complete card and termination markings, controller and software release, segment topology, device list and relevant diagnostic record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
KJ3243X1-BK1 SE4022 12P4691X042Product Details -
KJ3002X1-BA1 12P0680X072 VE4003S2B2Product Details -
KJ3221X1-BA1 12P2531X102Product Details -
KJ1501X1-BC1 12P2186X032 VE5008Product Details -
KJ3201X1-BA1 12P2535X052Product Details -
KJ2002X1-BA1 12P1442X042 VE3002Product Details -
PR6424/013-140 CON021/914-100Product Details -
PHARPSPEP11013Product Details -
40CN3210BProduct Details -
PR6423/002-121 CON041Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.