Speak to a sourcing specialist
sales13@apterpower.com

KJ3209X1-BA1 12P3905X012 VE4002S2T1B1

DeltaV 8-Channel 115/230 V AC Isolated Discrete Output Assembly
In Stock
Ships by Saturday, November 28
Fast Shipping Available
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (1)
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (2)
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (3)
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (1)
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (2)
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 is a DeltaV eight-channel 115/230 V AC isolated discrete-output assembly. VE4002S2T1B1 uses the standard I/O termination block.
Get a quick price for KJ3209X1-BA1 12P3905X012 VE4002S2T1B1
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ3209X1-BA1 12P3905X012 VE4002S2T1B1

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3209X1-BA1 12P3905X012 VE4002S2T1B1
  • Estimated shipping dimensions:
    22.5x14x5cm
  • Weight:
    0.38 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Current verified Emerson code:
    VE4002S2T1B1
  • I/O function:
    Discrete output
  • Channels:
    8
  • Field signal:
    115/230 V AC
  • Output range:
    20 to 250 V AC
  • Output rating per channel:
    1.0 A continuous
  • Maximum card load to 60 deg C:
    2.0 A
  • Maximum card load to 50 deg C:
    3.0 A
  • Off-state leakage at 120 V AC:
    2 mA maximum
  • Off-state leakage at 230 V AC:
    4 mA maximum
  • Isolation:
    250 V AC from system and between channels
  • LocalBus current:
    100 mA typical, 150 mA maximum
  • Termination block:
    Standard I/O termination block
  • Configurable modes:
    Discrete, momentary and continuous pulse output

Information

Overview Manuals Common Applications Product Precautions
Emerson KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 is a DeltaV eight-channel 115/230 V AC isolated discrete-output assembly. VE4002S2T1B1 uses the standard I/O termination block.
  • Eight isolated AC discrete-output channels
  • 115/230 V AC field switching
  • Standard I/O termination block
  • Discrete, momentary and continuous pulse modes

Use KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 only in its documented DeltaV 8-Channel 115/230 V AC Isolated Discrete Output Assembly position with matching power, wiring and configuration. Commissioning must verify the exact installed architecture and controlled system response.

Important Notice: Confirm the complete KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 identity, host position, interfaces, configuration and acceptance evidence before release.

KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 Manuals & Downloads

These documents are different: the first consolidates exact product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

DeltaV 8-Channel 115/230 V AC Isolated Discrete Output Assembly
Supports the exact documented KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 system role.
Cabinet integration
Retains the approved host position, connectors and wiring.
Maintenance replacement
Restores the recorded KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 hardware execution.
Controlled commissioning
Verifies diagnostics and the assigned product function before release.
Read the applicable official installation instructions before work. Verify KJ3209X1-BA1 12P3905X012 VE4002S2T1B1, the installed host system and all configured interfaces before isolation, wiring or commissioning.
1
Verify the complete KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 marking and documented hardware execution before work.
2
Place the connected process and control system in the approved maintenance state.
3
Isolate every documented power, signal and stored-energy source.
4
Record the installed position, keyed interfaces, terminals and active configuration.
5
Use ESD controls and protect connectors, contacts and field wiring.
6
Restore only the exact documented power, wiring, grounding and configuration.
7
Energize in a controlled sequence and review KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 diagnostics.
8
Function-test the assigned DeltaV 8-Channel 115/230 V AC Isolated Discrete Output Assembly role before release.

Technical notes

Install KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 only in the documented DeltaV M-series Traditional I/O arrangement. Preserve identity, keying, wiring and configuration, then verify diagnostics and switching eight isolated 115/230 V AC field-output circuits through a standard terminal block under controlled conditions.

FAQ View All FAQ

  • Which assembly function is confirmed for KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    VE4002S2T1B1 is the standard-termination assembly for eight isolated 115/230 V AC discrete outputs.
  • What output-voltage range applies to KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    The documented operating range is 20 to 250 V AC.
  • What is the continuous channel rating of KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    Each output channel is rated 1.0 A continuous, subject to the card-total temperature limits.
  • How does temperature limit KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 total load?
    The card maximum is 2.0 A through 60 deg C or 3.0 A through 50 deg C.
  • What off-state leakage must be considered for KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    Allow up to 2 mA at 120 V AC and 4 mA at 230 V AC.
  • How are KJ3209X1-BA1 12P3905X012 VE4002S2T1B1 outputs isolated?
    Each channel is isolated from the system and other channels at 250 V AC.
  • Which termination style belongs to KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    The B1 suffix identifies the standard I/O termination block, not the fused B2 version.
  • What completes commissioning of KJ3209X1-BA1 12P3905X012 VE4002S2T1B1?
    Verify keying, voltage class, total loading, leakage, timing mode and controlled operation of all assigned AC loads.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.