Emerson FBM205-P0914XG
Emerson FBM205-P0914XG
Emerson FBM205-P0914XG
Emerson FBM205-P0914XG
Emerson FBM205-P0914XG
Emerson FBM205-P0914XG
Product image is representative; revision or series may vary. Contact us to request a specific version.

FBM205-P0914XG

Analog I/O Module
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Emerson FBM205-P0914XG is a analog i/o module for the Foxboro I/A Series fieldbus module platform. It is the P0914XG FBM205 analog I/O module with four two-wire inputs and four two-wire outputs.

Ask our team:

Get a quick price for: FBM205-P0914XG
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FBM205-P0914XG

Technical specifications for FBM205-P0914XG

  • Manufacturer:
    Emerson
  • Product Category:
    DCS System
  • Spare Part Number:
    FBM205-P0914XG
  • Estimated shipping dimensions:
    4.5x11x11.5cm
  • Weight:
    0.32 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product family:
    Foxboro I/A Series fieldbus module platform
  • Module designation:
    FBM205
  • Part number:
    P0914XG
  • Analog input channels:
    4 two-wire channels
  • Analog output channels:
    4 two-wire channels
  • Baseplate mounting:
    DIN-rail or rack-mounted baseplate
  • Redundant arrangement:
    Adjacent paired modules when configured
  • Field connector:
    25-pin male D-sub
  • Cable length:
    Up to 30 m with documented termination cable
  • Current successor:
    RH914XG, subject to project migration review
  • System family:
    Foxboro I/A Series

Information

Information

Overview Manuals Common Applications Product Precautions
Foxboro FBM205-P0914XG is the P0914XG FBM205 analog I/O module with four two-wire inputs and four two-wire outputs.
  • Combines four analog inputs and four analog outputs
  • Supports baseplate fieldbus installation
  • Permits documented redundant pairing
  • Uses the P0914XG hardware identity

FBM205-P0914XG operates with its documented companion hardware and configured system interfaces.

Engineered applications include Mixed analog I/O, Redundant process I/O, Remote termination, Legacy module renewal.

Important Notice: Confirm P0914XG, baseplate position, termination assembly, cable type and all eight channel assignments. Do not apply successor hardware without an approved migration review.

Emerson FBM205-P0914XG Manuals & Downloads
Emerson FBM205-P0914XG Technical Reference (PDF)Emerson FBM205-P0914XG Installation & Commissioning Guide (PDF)
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Mixed analog I/O
Handles four input and four output loops at one fieldbus position.
Redundant process I/O
Operates as an adjacent pair where the project defines redundancy.
Remote termination
Connects to the documented termination assembly through the specified cable.
Legacy module renewal
Restores P0914XG while preserving database and loop assignments.
Read the applicable Emerson instructions before work. Verify FBM205-P0914XG, the installed system and every configured interface before isolation, wiring or commissioning.
1
Confirm the complete FBM205-P0914XG marking and installed analog-I/O position before work.
2
Place the connected process in the approved maintenance state.
3
Isolate every applicable power and field circuit before disconnection.
4
Record connector, terminal, address, slot and companion-hardware identities.
5
Use grounded ESD controls and protect keyed interfaces from damage.
6
Preserve documented polarity, shielding, grounding and cable routing.
7
Restore power in the approved sequence and review diagnostics.
8
Prove the intended input, output or communications response and retain the acceptance record.

Alternative Names

Alternative Names

FBM205-P0914XG FBM205P0914XG Emerson FBM205-P0914XG

Technical notes

Technical notes

Confirm P0914XG, baseplate position, termination assembly, cable type and all eight channel assignments. Do not apply successor hardware without an approved migration review.

FAQS

  • What module designation should be verified before FBM205-P0914XG is installed?
    Module designation: FBM205. Check this item before reconnecting field power.
  • How should the part number be matched for this analog i/o module?
    Part number: P0914XG. Include the result in the final functional test.
  • How can the analog input channels prevent an incorrect FBM205-P0914XG substitution?
    Analog input channels: 4 two-wire channels. Preserve the setting when transferring the approved configuration.
  • Why must technicians record the analog output channels before removing FBM205-P0914XG?
    Analog output channels: 4 two-wire channels. Verify the nameplate and controlled project record agree.
  • When servicing FBM205-P0914XG, how should the baseplate mounting be confirmed?
    Baseplate mounting: DIN-rail or rack-mounted baseplate. Use this value when checking the analog i/o module against its installed position.
  • How does the redundant arrangement affect replacement of FBM205-P0914XG?
    Redundant arrangement: Adjacent paired modules when configured. Retain it in the controlled replacement record.
  • What does the field connector mean for FBM205-P0914XG system compatibility?
    Field connector: 25-pin male D-sub. Compare it with the existing terminal and companion-hardware assignment.
  • Which acceptance record should retain the cable length for FBM205-P0914XG?
    Cable length: Up to 30 m with documented termination cable. Apply it during the pre-energization wiring review.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.