Match the complete marking
Match the complete Emerson EZ1081-04-00-010 + EZ1901-040 marking and the installed configuration. Compare both component labels and the 5 m calibrated chain.
-
Check the offered item before ordering
Please request clear photographs of Emerson EZ1081-04-00-010 + EZ1901-040, including its complete label and interfaces. Ask your maintenance team to compare the offered unit with the installed equipment and the applicable Emerson AMS EZ 1000 sensor installation guide before approving the order.
Technical specifications for EZ1081-04-00-010 + EZ1901-040
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:EZ1081-04-00-010 + EZ1901-040
-
Weight:0.2 kg
-
Tariff Code:8537101190
-
Sensing tip:8 mm
-
Mounting thread:M10 × 1
-
Case length:40 mm
-
Ordered unthreaded section:00; fixed 5 mm tip neck still present
-
Integral lead:1 m; armoured
-
Extension cable:4 m; armoured
-
Total electrical length:5 m
-
Nominal sensitivity:8 V/mm ISO; 7.87 V/mm API
-
Nominal gap:1.5 mm
-
Probe temperature:-35 to +180 °C, including 1 m lead
-
Extension / connector temperature:-35 to +150 °C
-
Armoured-cable bend radius:Minimum 35 mm
Information
- A 1 m armoured probe and 4 m armoured extension establish the standard 5 m measurement chain. This combination is particularly relevant when the installed EZ1000 calibration uses the 5 m API reference arrangement.
Cable chain: 1 m probe lead + 4 m armoured extension
Converter matching: 5 m complete electrical length
The EZ1901 extension contributes 4 m to the 5 m chain. A compatible EZ1000 converter must be calibrated for the complete assembly and intended target. The nominal scale factor is 8 V/mm for ISO calibration or 7.87 V/mm for API calibration; a 1.5 mm nominal gap is a reference point within the matched system.
The standard 5 m combination supports the special 2000 µm peak-to-peak recommendation only with the specified API calibration on 42CrMo4. Other configurations use the stated general 1250 µm peak-to-peak recommendation. Probe and integral cable operation is -35 to +180 °C, while extension cables and connectors are limited to -35 to +150 °C.
EZ1081-04-00-010 + EZ1901-040 Official Technical Excerpt
Technical material for Emerson EZ1081-04-00-010 + EZ1901-040 covers probe construction, 40 mm case selection, 4 m armoured extension and calibrated-chain limits. PDF · 10 pages.EZ1081-04-00-010 + EZ1901-040 Installation & Verification Guide
Apter Power installation and verification guide covering 40 mm mounting, 5 m chain identification, armoured cable routing and target-response verification. PDF · 5 pages.
Application scope: A 1 m armoured probe and 4 m armoured extension establish the standard 5 m measurement chain. This combination is particularly relevant when the installed EZ1000 calibration uses the 5 m API reference arrangement.
Relative shaft vibration
Observe target displacement through the complete calibrated eddy-current chain.40 mm mounting body
Use the selected case geometry to position the 8 mm sensing tip while retaining the fixed neck clearance.4 m cable reach
Route the armoured extension to the converter without changing the 5 m total electrical length.Static position measurement
Set and verify the target operating point using the matched converter output and intended calibrated range.
Do not cut or splice the 5 m chain or exchange extension lengths without matching calibration.
Maintain the specified target area, surrounding-metal clearance and fixed neck clearance.
Limit EZ108x locknut torque to 15 N·m and prevent cable twisting.
Keep extension cables and connectors within +150 °C even if the probe location permits +180 °C.
Use the specified hand-tightened connection and heat-shrink insulation; apply additional hazardous-area requirements where relevant.
Verify gap, target response and channel indication before restoring machinery monitoring.
Alternative Names
Technical notes
Signal relationship: Total electrical length is 1 m + 4 m = 5 m. Mechanical case length does not change this calculation and does not establish the displacement range.
Installation boundary: Keep the armoured cable bend radius at least 35 mm and stored loop diameter at least 100 mm. Avoid continuous oil immersion and direct oil-stream exposure; leave allowance for installation and thermal movement.
Technical basis: Emerson AMS EZ 1000 Sensor Installation Guide, MHM-97883 Rev. 1.09, January 2025. The order-code tables map the 40 mm EZ1081 probe and 4 m EZ1901 extension to a 5 m chain. Performance remains conditional on target and matched converter calibration.
FAQ View All FAQ
-
How does the cable combination in EZ1081-04-00-010 + EZ1901-040 produce a 5 m chain?The EZ1081 probe contributes a 1 m integral lead and EZ1901-040 adds 4 m. The converter must be calibrated for that complete 5 m combination.
-
When can EZ1081-04-00-010 + EZ1901-040 use the 2000 µm peak-to-peak recommendation?That recommendation is specific to the standard 5 m chain with a 1 m probe cable, 4 m extension and API calibration on 42CrMo4. It is not a universal rating for every target and calibration.
-
What does the 04 case option specify in EZ1081-04-00-010 + EZ1901-040?It selects a 40 mm probe case. The separate 00 option sets the ordered unthreaded case section to zero; the fixed neck at the sensing tip still requires clearance.
-
Why does EZ1081-04-00-010 + EZ1901-040 require a matched EZ1000 calibration?The probe, extension and converter operate as one measurement chain. Electrical length, target material and calibration convention affect scale factor and usable range.
-
Which bend radius applies to the armoured cable in EZ1081-04-00-010 + EZ1901-040?The minimum bend radius for armoured cable is 35 mm. When storing a loop, keep the coil diameter at least 100 mm.
-
Does the full EZ1081-04-00-010 + EZ1901-040 assembly share the probe tip temperature limit?No. The probe with its 1 m cable is specified from -35 to +180 °C, but the extension cable and connectors are limited to -35 to +150 °C.
-
How should the connector joint in EZ1081-04-00-010 + EZ1901-040 be insulated?Tighten the connection by hand and install the specified black heat-shrink insulation. Additional hazardous-area provisions apply when required by the installation.
-
What sensor-face clearance should be retained around EZ1081-04-00-010 + EZ1901-040?Avoid nearby metallic objects within the probe clearance zone. The 8 mm sensor geometry uses a recommended free diameter of at least 24 mm around the sensing region; the actual mounting drawing and target geometry must agree.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.