Technical specifications for 990-05-XX-03-CN 104M6732-01
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:990-05-XX-03-CN 104M6732-01
-
Estimated shipping dimensions:10×7.4×5.8cm
-
Weight:0.5 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Reference Document:990 Vibration Transmitter, 141612 Rev. Y
-
Measurement Role:Overall vibration input to a machinery control system
-
Series Output Architecture:Two-wire, loop-powered 4-20 mA
-
Series Conditioning:Integrated Proximitor
-
Special Identifier:104M6732-01; meaning not specified in the supplied reference
-
990 Series Reference - Supply at Transmitter:+12 to +35 VDC; approval-specific circuit limits also apply
-
990 Series Reference - Process Output:4-20 mADC, two-wire, proportional to configured full scale
-
990 Series Reference - Loop Accuracy:Within +/-1.5% of full scale, TEST input to a 250-ohm loop
-
990 Series Reference - Loop Accuracy Boundary:Additional to PROX OUT incremental scale-factor error
-
990 Series Reference - Maximum Loop Resistance:1000 ohm including cable at 35 VDC
-
990 Series Reference - Current Limiting:23 mA typical
-
990 Series Reference - Not OK Output:Below 3.6 mA within 100 us after a Not OK condition
-
990 Series Reference - Not OK Recovery:2-3 seconds after the fault condition is removed
-
990 Series Reference - Power-up Inhibit:Output below 3.6 mA for 2-3 seconds
-
990 Series Reference - Zero and Span:Independent external adjustments under the label
-
990 Series Reference - Diagnostic Output:Non-isolated PROX OUT / COM and coaxial connector
-
990 Series Reference - PROX OUT Impedance:10 kohm, calibrated for a 10 Mohm load
-
990 Series Reference - PROX OUT Cable Limit:3 m maximum from the BNC diagnostic output
-
990 Series Reference - Grounded Test Equipment Interface:122115-01 test adapter for signal isolation
-
990 Series Reference - Transducer-system Frequency Range:5-6000 Hz
-
990 Series Reference - Transmitter Operating Temperature:-35 to +85 deg C; installed approval limits also apply
-
990 Series Reference - Storage Temperature:-52 to +100 deg C
-
990 Series Reference - Humidity:100% condensing, non-submerged, with protected coaxial connectors
Information
- Measurement Role: Overall vibration input to a machinery control system.
- Series Output Architecture: Two-wire, loop-powered 4-20 mA.
- Series Conditioning: Integrated Proximitor.
- Complete configuration: 990-05-XX-03-CN 104M6732-01 identifies this vibration transmitter.
During installation, check supply polarity, loop resistance, probe-chain condition and the receiving channel before applying the measurement to protection or control logic. Verify the live output at the machine operating point after zero, span and cable routing have been confirmed.
Important Notice: The supplied 141612 Rev. Y datasheet is a series reference. It does not identify 104M6732-01 or resolve XX and CN for this execution. Standard ordering meanings and series ratings do not independently confirm special-execution calibration, component compatibility or certification.
The technical reference covers 990-series loop, diagnostic and environmental reference data with special-execution boundaries. The installation guide covers identity review, mounting, circuit and diagnostic checks, and functional acceptance.
Technical notes
FAQ View All FAQ
-
How is the measurement role specified for 990-05-XX-03-CN 104M6732-01?Measurement Role is Overall vibration input to a machinery control system.
-
What output does 990-05-XX-03-CN 104M6732-01 provide?Series Output Architecture is Two-wire, loop-powered 4-20 mA.
-
How is the series conditioning specified for 990-05-XX-03-CN 104M6732-01?Series Conditioning is Integrated Proximitor.
-
How is the special identifier specified for 990-05-XX-03-CN 104M6732-01?Special Identifier is 104M6732-01; meaning not specified in the supplied reference.
-
What power requirement applies to 990-05-XX-03-CN 104M6732-01?Supply at Transmitter is +12 to +35 VDC; approval-specific circuit limits also apply.
-
What accuracy is specified for 990-05-XX-03-CN 104M6732-01?Loop Accuracy is Within +/-1.5% of full scale, TEST input to a 250-ohm loop.
-
What should be checked before energizing 990-05-XX-03-CN 104M6732-01?Confirm supply polarity, loop resistance, probe-chain condition, shielding and the receiving control input before power is applied.
-
How should 990-05-XX-03-CN 104M6732-01 be commissioned?Check the live loop output, diagnostic signal, zero and span at the installed machine point, then record the accepted readings.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.