Product image is representative; revision or series may vary. Contact us to request a specific version.
Product Describe:
Bently Nevada 9200-01-20-10-00 is 9200 two-wire seismoprobe velocity transducer for the 9200 Seismoprobe velocity transducer system. The code specifies a vertical 4.5 Hz transducer with a 20 ft integral cable and circular M10 x 1 base.
Bently Nevada 9200-01-20-10-00 is 9200 two-wire seismoprobe velocity transducer for the 9200 Seismoprobe velocity transducer system. The code specifies a vertical 4.5 Hz transducer with a 20 ft integral cable and circular M10 x 1 base.
Uses a zero-degree mounting orientation
Has a 4.5 Hz minimum operating frequency
Includes a 20 ft integral cable
Uses a circular M10 x 1 mounting stud
Maintain the documented orientation, base interface, cable routing and two-wire polarity.
Important Notice: Confirm the complete 9200-01-20-10-00 identity, installed-system configuration, approved isolation and functional acceptance record before service release.
Important Notice: The first document presents model-specific technical data and engineering questions. The second provides a separate installation, commissioning and acceptance workflow.
Continuous machinery monitoring
Processes the assigned machine variable continuously for condition and protection use.
Alarm integration
Transfers configured alert and danger status to the plant protection workflow.
Diagnostic review
Provides buffered or host-visible information for controlled troubleshooting.
Documented system renewal
Restores the installed rack or transmitter position without changing the approved measurement intent.
Read the applicable Bently Nevada installation instructions before work. Verify 9200-01-20-10-00 and the installed-system configuration before commissioning.
1
Verify the complete 9200-01-20-10-00 marking and the assigned 9200 Seismoprobe velocity transducer system position before work.
2
Place the connected machinery and monitoring channel in the approved maintenance state before handling 9200-01-20-10-00.
3
Isolate every documented supply and field circuit before disconnecting 9200-01-20-10-00.
4
Record the installed connectors, conductors, cable routing and configuration associated with 9200-01-20-10-00.
5
Use ESD controls and protect exposed connectors, cable ends and keyed interfaces while handling 9200-01-20-10-00.
6
Confirm the documented companion hardware and ordering options for 9200-01-20-10-00 before energizing.
7
Restore power in a controlled sequence and review monitor, rack and host diagnostics for 9200-01-20-10-00.
8
Complete a controlled functional test and retain the final acceptance record for 9200-01-20-10-00.
Technical notes
Maintain the documented orientation, base interface, cable routing and two-wire polarity.
What mounting angle is specified for 9200-01-20-10-00?
For 9200-01-20-10-00, the documented mounting angle is 0 degrees +/-2.5 degrees.
What minimum operating frequency is specified for 9200-01-20-10-00?
For 9200-01-20-10-00, the documented minimum operating frequency is 4.5 Hz.
What integral hardline cable is specified for 9200-01-20-10-00?
For 9200-01-20-10-00, the documented integral hardline cable is 20 ft.
What mounting base is specified for 9200-01-20-10-00?
For 9200-01-20-10-00, the documented mounting base is Circular M10 x 1 stud.
What agency approval is specified for 9200-01-20-10-00?
For 9200-01-20-10-00, the documented agency approval is None.
How is 9200-01-20-10-00 used in the documented 9200 Seismoprobe velocity transducer system?
It is used in the 9200 Seismoprobe velocity transducer system to provide two-wire casing-vibration velocity signal.
Which installation record is essential for 9200-01-20-10-00?
Retain the installed position, companion hardware, field-connection identity and final functional-test result for 9200-01-20-10-00.
What must be confirmed during final acceptance of 9200-01-20-10-00?
Confirm the exact ordering identity, documented companion hardware, restored field connections and a controlled functional test of the 9200 Seismoprobe velocity transducer system before service release.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
Please try to be as accurate as possible with your search.
We can quote you on 1000s of specialist parts, even if they are not listed on our website.