Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

84661-84661-08

Armored Interconnect Cable
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Bently Nevada 84661-84661-08 is an 8 ft armored interconnect cable for 9200 and 74712 Seismoprobe Velocity Transducer signal wiring to monitors or vibration data collectors.

Ask our team:

Get a quick price for: 84661-84661-08
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 84661-84661-08

Technical specifications for 84661-84661-08

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    84661-08
  • Estimated shipping dimensions:
    27x27x3cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product family:
    9200 and 74712 Seismoprobe interconnection cables
  • Requested identity:
    84661-84661-08
  • Catalog cable code:
    84661-08
  • Cable family:
    84661-NN
  • Length option:
    08 = 8 ft (approximately 2.4 m)
  • Conductors:
    2-conductor
  • Cable construction:
    Twisted and shielded
  • Conductor size:
    22 AWG (0.5 mm2)
  • Mechanical protection:
    Armored
  • Transducer end:
    2-socket moisture-resistant female connector
  • Instrument end:
    Terminal lugs
  • Intended instrument side:
    Monitor or vibration data collector
  • Cable operating temperature:
    -50 C to 120 C
  • Available family range:
    3 ft minimum to 99 ft maximum
  • Supported transducer families:
    9200 and 74712 Seismoprobe

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 84661-84661-08 is the 8 ft armored interconnect-cable configuration for 9200 and 74712 Seismoprobe Velocity Transducer signal wiring to monitors or vibration data collectors.
  • Maintains the armored cable path in a 9200 or 74712 velocity-measurement chain
  • Connects the transducer receptacle to instrument-side terminal wiring
  • Retains the documented 08 cable-length option for the installed run
  • Supports monitor or vibration-data-collector terminations

84661-84661-08 operates with 9200 or 74712 Seismoprobe Velocity Transducer, 84661-08 armored interconnect cable, monitor or vibration data collector, documented shield and terminal arrangement.

Engineered applications include Seismoprobe monitor connection, Vibration data collection, Armored field routing, Exact cable renewal.

Important Notice: Use 84661-84661-08 only with the documented 9200 or 74712 signal chain. Preserve the 08 length option, shield termination, connector orientation and instrument-terminal assignment before replacement.

Bently Nevada 84661-84661-08 Manuals & Downloads
Bently Nevada 84661-84661-08 Technical Reference (PDF)Bently Nevada 84661-84661-08 Installation & Commissioning Guide (PDF)

The first document presents exact-model technical and engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Seismoprobe monitor connection
Carries the two-wire velocity signal from a compatible 9200 or 74712 transducer to monitor terminal wiring.
Vibration data collection
Provides the connector-to-lug cable arrangement used with compatible vibration data collectors.
Armored field routing
Uses the documed armored construction where the approved installation requires additional mechanical protection.
Exact cable renewal
Restores the 84661-08 conductor, shield, connector, terminal-lug and length configuration without borrowing another cable-family option.
Read the applicable Bently Nevada instructions before work. Verify 84661-84661-08, the installed system and every configured interface before isolation, wiring or commissioning.
1
Confirm the complete 84661-84661-08 marking and the installed 9200 or 74712 signal path before work.
2
Place the connected monitor or vibration data collector in the approved maintenance state.
3
Isolate the affected instrument channel before loosening terminal lugs or the transducer connector.
4
Record conductor polarity, shield termination and every instrument-side terminal assignment.
5
Protect the two-socket female connector from contamination, impact and incorrect mating force.
6
Route the armored cable without exceeding the approved installation bend and support practice.
7
Verify the 08 length option is retained and do not substitute a neighboring 84661-NN cable length.
8
After reconnection, prove signal polarity, continuity and the expected velocity response before service release.

Alternative Names

Alternative Names

84661-84661-08 84661-08 84661-NN

Technical notes

Technical notes

Retain the 08 cable-length option, two-socket female connector, terminal-lug assignments, conductor polarity and shield termination when replacing Bently Nevada 84661-84661-08. Verify continuity and the expected velocity-signal response before service release.

FAQS

  • What does the 08 suffix define for Bently Nevada 84661-84661-08?
    The 08 code selects an 8 ft cable, approximately 2.4 m, from the 84661-NN interconnection-cable family.
  • Why is Bently Nevada 84661-84661-08 suited to protected field routing?
    Its documented construction combines a two-conductor twisted shielded cable with armor for additional mechanical protection.
  • Which transducer families can use Bently Nevada 84661-84661-08?
    The cable belongs to the interconnection options for 9200 and 74712 Seismoprobe Velocity Transducers.
  • How is Bently Nevada 84661-84661-08 terminated at the transducer end?
    The transducer end uses a two-socket moisture-resistant female connector.
  • What instrument-end termination is provided on Bently Nevada 84661-84661-08?
    The opposite end is supplied with terminal lugs for connection to the documented monitor or vibration-data-collector terminals.
  • What conductor specification must be retained for Bently Nevada 84661-84661-08?
    Retain the two-conductor twisted shielded 22 AWG construction, equivalent to 0.5 mm2 conductors.
  • What operating-temperature boundary applies to Bently Nevada 84661-84661-08?
    The published cable operating-temperature range is -50 C to 120 C.
  • Which checks confirm a successful Bently Nevada 84661-84661-08 cable renewal?
    Verify the 08 length, connector seating, terminal-lug polarity, shield termination, continuity and the expected velocity-signal response.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.