Bently Nevada 330101-00-18-10-02-05 is a configured 3300 XL proximity probe for machine vibration and position measurement.
- 3300 XL measurement chain
- Non-contact shaft sensing
- Configured probe assembly
- Machine-monitoring integration
330101-00-18-10-02-05 is installed as part of a matched 3300 XL proximity transducer system. Confirm the specified extension cable, Proximitor sensor, probe mounting, target gap, connector engagement and channel configuration before placing the measurement channel in service.
Important Notice: Confirm whether the required rack hardware, matched transducer chain, extension leads and configured protection accessories for 330101-00-18-10-02-05 are included in the quotation or stock description.
Apter Power 330101-00-18-10-02-05 Manuals and Guides
Important Notice: These are two separate Apter Power documents independently prepared from manufacturer-published information. Confirm the physical nameplate, current manufacturer documents and installed-system requirements before configuration or installation. They do not replace manufacturer manuals.
330101-00-18-10-02-05 installed-base maintenanceSupports like-for-like service of the documented configured 3300 XL 8 mm proximity probe.
330101-00-18-10-02-05 compatibility reviewChecks host hardware, revision, companion components, wiring and configuration before replacement.
330101-00-18-10-02-05 installation planningDefines isolation, ESD, mounting, connection and parameter checks before field work.
330101-00-18-10-02-05 commissioningSupports controlled diagnostic, channel, communication or process-response checks after installation.
Read the applicable Baker Hughes / Bently Nevada instructions before work. Verify 330101-00-18-10-02-05 and the installed-system configuration.
1Verify model 330101-00-18-10-02-05 and the complete order code on the physical label before use.
2Confirm all five option blocks and use a matching 1.0 m 330180 Proximitor without an extension cable; verify target material, mounting and approval drawing.
3Match every 330101-00-18-10-02-05 connector, terminal, cable and companion assembly before moving field wiring.
4Back up the applicable controller, monitor, HMI or I/O configuration before replacing 330101-00-18-10-02-05.
5Isolate energy and follow the approved site safety procedure before handling 330101-00-18-10-02-05.
6Follow ESD controls and protect 330101-00-18-10-02-05 connectors and printed-circuit assemblies during handling.
7Do not transfer ratings or suffix meanings from a similar model to 330101-00-18-10-02-05.
8After installing 330101-00-18-10-02-05, complete the relevant power, channel, link, diagnostic, alarm and fail-state checks.