Match the complete marking
Include 330901-00-36-10-11-05 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connection photos. Have your maintenance team compare the offered 330901-00-36-10-11-05 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330901-00-36-10-11-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330901-00-36-10-11-05
-
Weight:0.05 kg
-
Tariff Code:8537101190
-
Transducer family:3300 XL NSv
-
Mounting thread:1/4-28 UNF
-
Lead armor:None
-
Unthreaded length:0.0 in (00 option)
-
Overall case length:3.6 in
-
Integral lead length:1.0 m
-
Connector and cable:ClickLoc with protector and FluidLoc cable
-
Approval option:Multiple approvals (05)
-
Matched-system linear range:1.5 mm (60 mils)
-
Recommended matched-system gap:1.0 mm (40 mils)
-
Probe operating range:-52 to +177 deg C
Information
- Bently Nevada 330901-00-36-10-11-05 is a 1/4-28 UNF 3300 XL NSv proximity probe without armor, with a 3.6 in case, 1.0 m lead and ClickLoc with protector and FluidLoc cable.
Chain dependency: Retain an approved NSv extension and Proximitor arrangement.
Acceptance record: Store the installed gap and output trend after replacement.
An NSv probe is one component of the calibrated probe, extension and Proximitor chain. The manufacturer 1.5 mm linear range and 1.0 mm recommended gap are complete-system reference values, not a standalone output specification for this probe.
Set the sensing position against the actual conductive target and machine clearance. Preserve the installed total electrical length, cable termination and monitor scaling when replacing a probe.
-
Bently Nevada 330901-00-36-10-11-05 technical reference
Original manufacturer Bently Nevada 3300 XL NSv Proximity Transducer System, 147385 Rev. R. Family specifications and ordering information. -
Bently Nevada 330901-00-36-10-11-05 engineering guide
Apter Power installation, interface and fault-isolation guide for the offered complete model.
Platform applications: The applications below describe the complete measuring-channel functions. Verify the target, mounting position and approved channel design before selecting a replacement.
-
Tight machine clearance
Use the NSv probe at a documented narrow sensing location where a conventional tip geometry is unsuitable. -
Radial shaft vibration
Observe shaft motion at a bearing location with a matched NSv channel and verified probe spacing. -
Axial position
Measure thrust movement only with sufficient travel inside the calibrated NSv linear span. -
Maintenance replacement
Compare thread, case reach, cable construction and approval marking with the removed probe before energizing.
Confirm the 1/4-28 UNF port and 3.6 in reach against the installed drawing.
Protect the selected cable construction from abrasion, bends and liquid migration.
Inspect the ClickLoc joint and protector for complete engagement.
Match extension length and NSv Proximitor before applying a system scale.
Check nearby conductive metal and set the actual operating gap.
Verify site approval requirements against the exact supplied label and circuit.
Alternative Names
Technical notes
Installation relationship: Confirm the 1/4-28 UNF port and 3.6 in reach against the installed drawing.
Measurement boundary: Match extension length and NSv Proximitor before applying a system scale.
Technical reference: Bently Nevada 3300 XL NSv Proximity Transducer System, 147385 Rev. R.
FAQ View All FAQ
-
How can an NSv channel using 330901-00-36-10-11-05 produce a plausible DC gap but incorrect scale?A mismatched extension or Proximitor can alter calibration even with a live voltage. Verify all three part markings and the complete electrical length.
-
What target change can shift the gap response of 330901-00-36-10-11-05?A different alloy or nearby conductive metal changes eddy-current coupling. Recheck the installed target and actual clearance before changing monitor settings.
-
How should connector contamination on 330901-00-36-10-11-05 be diagnosed?Isolate the channel, inspect both ClickLoc surfaces and protector, then compare the disconnected probe resistance with the manufacturer reference.
-
What can create cross-talk between 330901-00-36-10-11-05 and a nearby probe?Tips too close together can couple through the target. Review the manufacturer spacing guidance and compare live channels at their operating gaps.
-
Why should the cable construction of 330901-00-36-10-11-05 be matched during replacement?The cable option affects liquid migration protection and routing. Confirm the offered cable and connector against the installed site requirement.
-
When should the gap of 330901-00-36-10-11-05 be verified again?Repeat the as-left gap check after the case position, target, extension or Proximitor changes; use the actual machine target.
-
Which system conditions affect the high-frequency response with 330901-00-36-10-11-05?Field-wire length, termination, load and barriers can roll off dynamic content. Compare the installed arrangement with the applicable NSv response curve.
-
What evidence completes an as-left check for 330901-00-36-10-11-05?Retain complete component markings, electrical length, measured probe resistance, target details, gap voltage and the operating signal trend.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.