Speak to a sourcing specialist
sales13@apterpower.com

330192-00-25-10-00

3300 XL 8 mm Extended Temperature Range Armored Proximity Probe
In Stock
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 330192-00-25-10-00 is an armored 3300 XL 8 mm extended-temperature proximity probe with a 3/8-24 UNF case, 2.5 in overall case length and 1.0 m integral cable.
  • Manufacturer part number
    330192-00-25-10-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    20cm x 20cm x 2.5cm
  • Country of Origin
    USA
Get a quick price for 330192-00-25-10-00
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 330192-00-25-10-00 marking, quantity and label photos so the 3300 xl 8 mm extended temperature range armored proximity probe options can be checked.
  • 1

    Confirm the offer

    Review the quoted condition, exact 330192-00-25-10-00 identity, included items and expected dispatch date before approving the order.
  • 2

    Arrange dispatch

    Confirm delivery details and packaging for 330192-00-25-10-00; receive the tracking reference when the shipment is arranged.
  • Match the complete marking

    Include 330192-00-25-10-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connection photos. Have your maintenance team compare the offered 330192-00-25-10-00 with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 330192-00-25-10-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330192-00-25-10-00
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Probe family:
    3300 XL 8 mm extended-temperature range
  • Mounting thread:
    3/8-24 UNF-2A
  • Cable armor:
    Stainless-steel armor
  • Unthreaded length:
    0.0 in (00 option)
  • Overall case length:
    2.5 in
  • Integral lead length:
    1.0 m
  • Approval option:
    00; agency approval not required
  • Probe tip:
    8 mm nominal diameter
  • Probe-tip temperature:
    -52 to +218 deg C, ETR design
  • Cable and connector temperature:
    -51 to +260 deg C, ETR design
  • Matched-system linear range:
    2.0 mm (80 mils), reference setup

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 330192-00-25-10-00 is an armored 3300 XL 8 mm extended-temperature proximity probe with a 3/8-24 UNF case, 2.5 in overall case length and 1.0 m integral cable.
Replacement decision: Compare the machine entry and available cable route with the removed assembly.
Chain dependency: The probe requires its matched Proximitor to produce the monitor signal.
Acceptance record: Retain the as-left gap and live vibration baseline after installation.
The 330192 order family identifies an armored, standard-mount ETR probe. The 00 and 25 geometry options specify a fully threaded 2.5 in case, while the selected lead is 1.0 m. Use the complete marking when matching the replacement to the installed mounting and cable route.

The eddy-current probe is one element of a 3300 XL 8 mm measuring chain. The published 2.0 mm linear range and 7.87 V/mm incremental scale belong to a matched system on the manufacturer reference target; the probe alone has no standalone voltage output.

ETR ratings distinguish the sensing tip from its cable and connector. Locate the latter within their own environmental limits, confirm the installed Proximitor length and set the operating gap against the approved machine baseline.
Controller platform reference: 3300 XL 8 mm ETR transducer system. Match the probe, cable length and Proximitor to the installed channel.
Technical downloads for 330192-00-25-10-00: an original manufacturer technical reference and an Apter Power engineering guide.
Use the original technical reference for family values and the engineering guide for the installed-system checks.
System and supply context: 330192-00-25-10-00 belongs to the 3300 XL 8 mm extended-temperature range family. The selected component must be matched with the installed monitor, cable and connection arrangement; any companions are included only when itemized in the offer.

Platform applications: The applications below describe the complete measuring-channel functions. Verify the target, mounting position and approved channel design before selecting a replacement.
Prepare 330192-00-25-10-00 using the exact installed identity, machine drawing and site isolation procedure.
Mounting reach

Compare the fully threaded 2.5 in case and 3/8-24 machine port with the installed drawing before setting gap.

Armor route

Avoid sharp bends and abrasion at the armor ferrule; support the lead without stressing the case exit.

Matched electrical length

Confirm the 1.0 m probe lead is paired with the corresponding 3300 XL 8 mm Proximitor arrangement.

Target response

Do not transfer the AISI 4140 reference scale to a different alloy without an installed-system check.

Connector condition

Inspect and protect the miniature coaxial joint against contamination and liquid entry.

As-left result

Record the final gap voltage and running signal against the approved channel baseline.

Alternative Names

Bently Nevada 330192-00-25-10-00

Technical notes

Installation relationship: Compare the fully threaded 2.5 in case and 3/8-24 machine port with the installed drawing before setting gap.

Measurement boundary: Do not transfer the AISI 4140 reference scale to a different alloy without an installed-system check.

Technical reference: Bently Nevada 3300 XL 8 mm Proximity Transducer System, 141194 Rev. AN.

FAQ View All FAQ

  • What changes in the channel if 330192-00-25-10-00 is paired with a Proximitor of the wrong electrical length?
    The calibration curve and scale can shift even if the channel still produces a plausible voltage. Match the complete probe lead, any extension and Proximitor length before acceptance.
  • Why can 330192-00-25-10-00 show a changed gap voltage after the target alloy is replaced?
    Eddy-current response depends on target conductivity and magnetic properties. Recheck the complete system against the actual target and record a new accepted gap baseline.
  • How should an intermittent signal from 330192-00-25-10-00 be isolated at the coaxial joint?
    With the channel isolated, inspect mating surfaces, connector retention and strain relief, then compare the probe-only resistance with the applicable manufacturer value before replacing electronics.
  • What can reduce the high-frequency response of a channel using 330192-00-25-10-00?
    Long field wiring, barriers or loading can attenuate the dynamic signal while static gap remains plausible. Check the approved monitor interface and manufacturer response curves.
  • When does the ETR construction of 330192-00-25-10-00 need a separate cable-temperature check?
    The ETR tip and cable/connector have distinct temperature limits. Assess actual temperatures at the sensing point, cable route and junction before release.
  • How can nearby metal affect the response of 330192-00-25-10-00?
    Metal within the probe field can produce side-view or rear-view effects. Compare counterbore and adjacent geometry with the machine drawing and verify the final gap in situ.
  • What routing defect can undermine the armor protection on 330192-00-25-10-00?
    Bending or pulling at the armor ferrule can damage the internal coaxial lead. Support the route and inspect the cable exit during an isolated continuity check.
  • Which acceptance values should be retained after replacing 330192-00-25-10-00?
    Keep the complete probe and Proximitor markings, probe resistance, target material, as-left gap voltage and live vibration trend with the machine maintenance record.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.