330190-080-00-00

3300 XL ETR Extension Cable
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Bently Nevada 330190-080-00-00 is an 8.0 m standard 3300 XL Extended Temperature Range extension cable. It completes the documented probe-to-Proximitor connection in a matched 3300 XL 8 mm ETR transducer system.

Ask our team:

Get a quick price for: 330190-080-00-00
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 330190-080-00-00

Technical specifications for 330190-080-00-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    330190-080-00-00
  • Estimated shipping dimensions:
    20x20x2cm
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Component:
    3300 XL Extended Temperature Range extension cable
  • Cable length:
    8.0 m
  • Cable option:
    Standard cable
  • Approval option:
    Not required
  • Cable construction:
    75 ohm triaxial, FEP insulated
  • Connector material:
    Gold-plated brass
  • Operating and storage temperature:
    -52 to +177 °C
  • Minimum bend radius:
    25.4 mm (1.0 in)
  • System compatibility:
    3300 XL 8 mm ETR proximity transducer system

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 330190-080-00-00 provides the documented 8.0 m signal extension for a matched 3300 XL 8 mm ETR transducer loop.
  • Extends the probe signal through the documented 8.0 m cable length
  • Uses standard 75 ohm triaxial FEP-insulated construction
  • Connects the ETR probe to the matched Proximitor Sensor
  • Supports the approved total-length transducer-system configuration

The cable links the installed ETR probe to its matched Proximitor Sensor and carries the eddy-current signal through the approved total system length. Commissioning confirms length matching, connector protection, routing, shielding and controlled monitor response.

Important Notice: Confirm 330190-080-00-00, 8.0 m cable length, standard cable execution, probe lead length, Proximitor Sensor system length, connector condition, route, minimum bend radius, shielding, grounding and controlled response-test results before commissioning.

Apter Power Bently Nevada 330190-080-00-00 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct installation, connection and commissioning workbook with field checks and acceptance records.

ETR proximity-loop cable replacement
Restores the documented cable span between probe and Proximitor Sensor.
High-temperature machine casing routes
Maintains the approved ETR signal path through the installed cable route.
Protection-channel refurbishment
Replaces the exact cable length without altering total system identity.
Controlled loop recommissioning
Supports connection, polarity, gap and response verification after cable work.
Read the applicable Bently Nevada installation instructions before work. Verify 330190-080-00-00, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the full 330190-080-00-00 marking, 8.0 m length and standard-cable execution before work.
2
Place the monitored machine and associated protection channel in the approved maintenance state.
3
Disconnect only after isolating the monitor loop and recording both connector positions.
4
Route the cable without violating the 25.4 mm minimum bend radius or applying tensile load.
5
Keep both ClickLoc connector interfaces clean, dry and protected from contamination.
6
Confirm probe length plus extension-cable length equals the Proximitor Sensor system length.
7
Restore shielding and field wiring without creating an unintended ground path.
8
Verify static gap, polarity, vibration response and alarm action before service release.

Technical notes

Technical notes

Use 330190-080-00-00 only when the probe lead plus 8.0 m extension cable equals the selected Proximitor Sensor total system length. Protect the FEP-insulated triaxial cable from sharp bends and contamination, then verify connector seating, shield continuity and channel response.

FAQS

  • How is Bently Nevada 330190-080-00-00 identified before replacement?
    Match the complete order number 330190-080-00-00, the product designation and every decoded option shown in the official ordering information.
  • Which host system is required for Bently Nevada 330190-080-00-00?
    Use only the documented Bently Nevada 3300 XL 8 mm Extended Temperature Range Proximity Transducer System execution with the matching mechanical, cable, power and monitor interfaces.
  • What must be recorded before removing Bently Nevada 330190-080-00-00?
    Record installed position, connectors or terminals, cable route, shielding, grounding, channel configuration, static state and active diagnostics.
  • How should Bently Nevada 330190-080-00-00 be isolated and handled?
    Place the monitored machine and associated protection channel in the approved maintenance state. Disconnect only after isolating the monitor loop and recording both connector positions.
  • Which official technical values govern Bently Nevada 330190-080-00-00?
    Complete order number: 330190-080-00-00; Component: 3300 XL Extended Temperature Range extension cable; Cable length: 8.0 m; Cable option: Standard cable; Approval option: Not required; Cable construction: 75 ohm triaxial, FEP insulated.
  • How is compatibility checked for Bently Nevada 330190-080-00-00?
    Confirm probe length plus extension-cable length equals the Proximitor Sensor system length.
  • Which commissioning checks follow installation of Bently Nevada 330190-080-00-00?
    Restore shielding and field wiring without creating an unintended ground path. Verify static gap, polarity, vibration response and alarm action before service release.
  • What evidence releases Bently Nevada 330190-080-00-00 to service?
    Retain the identity check, as-left connection record, configuration record, diagnostic result and controlled functional-test result for the affected channel.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.