Match the complete marking
Include the complete Bently Nevada 330104-01-08-50-01-05 marking and any hardware revision on the item. Compare the complete order code, mating interfaces and installed measurement chain.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 330104-01-08-50-01-05 with the installed equipment and applicable Bently Nevada documents.
Technical specifications for 330104-01-08-50-01-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330104-01-08-50-01-05
-
Weight:0.56 kg
-
Tariff Code:8537101190
-
Tip diameter:8 mm
-
Mounting thread:M10 x 1
-
Case length:80 mm
-
Unthreaded section:10 mm
-
Probe length:5.0 m
-
Lead protection:Armor and connector protector
-
Compatible system length:5 m only
-
Probe resistance:8.73 ohm ±0.50 ohm
-
System linear range:2 mm
-
System scale factor:7.87 V/mm
-
Reference gap:1.27 mm
Information
- Bently Nevada 330104-01-08-50-01-05 combines a protected five-metre probe lead with a partially unthreaded metric case for the matching 5 m measurement system.
Lead configuration: 5.0 m; armored standard cable with connector protector
Matched-system scale: 7.87 V/mm
The 80 mm metric case includes a 10 mm unthreaded section. Armor protects the standard cable, and the selected miniature ClickLoc connection includes a connector protector for the intended joint arrangement.
Route the available cable without cutting, splicing or forcing tight bends. After fitting the probe, verify the static gap and target response using the actual 5 m system rather than assuming that continuity alone proves calibration.
330104-01-08-50-01-05 Official Technical Excerpt
The original technical excerpt applicable to Bently Nevada 330104-01-08-50-01-05 covers system performance, probe connections and applicable order selections. PDF · 6 pages.330104-01-08-50-01-05 Installation & Verification Guide
Apter Power installation and verification guide covering mounting, cable matching, target clearance, gap and signal checks. PDF · 5 pages.
Application scope: Apply the M10 x 1 installation to its intended target and keep the selected 5.0 m probe length in the electrical-length calculation.
Direct five-metre chain
Connect the selected 5 m probe to its matching Proximitor.Protected cable route
Use armor and the connector protector in the intended machine installation.Partial-thread mounting
Retain the 10 mm unthreaded section and 80 mm case geometry.Radial vibration channel
Set the energized gap and check the matched-system output.
Match the M10 x 1 installation and selected case geometry.
Retain the armored standard cable with connector protector construction and avoid connector strain.
Match the probe and extension cable to the Proximitor calibration.
Assess target material and clearance before applying nominal sensitivity.
Establish the gap using the complete energized measurement chain.
Check static response, dynamic indication and configured alarms.
Alternative Names
Technical notes
Signal and interface: The 2 mm linear range and 7.87 V/mm scale factor belong to the complete matched system; the probe alone does not establish these ratings.
Installation boundary: The reference gap is 1.27 mm (approximately -9 V for radial vibration). Confirm target material, available travel and correct total electrical length before using the nominal calibration.
Technical basis: Bently Nevada 3300 XL 8 mm Proximity Transducer System, 141194 Rev. AN. Ordering selections apply to this complete probe code. Range, scale factor and gap are matched-system values under the specified calibration conditions.
FAQ View All FAQ
-
Can 330104-01-08-50-01-05 be used with a 9 m Proximitor by adding an extension?No. The 5 m probe execution is designed for the 5 m Proximitor only.
-
What are the threaded and unthreaded selections on 330104-01-08-50-01-05?The case is 80 mm overall with a 10 mm unthreaded section and M10 x 1 mounting.
-
Does 330104-01-08-50-01-05 include both armor and a connector protector?Yes. The 330104 construction adds armor and option 01 selects the standard ClickLoc connector with protector.
-
What probe resistance is expected from 330104-01-08-50-01-05?The nominal resistance for a 5.0 m probe is 8.73 ohm ±0.50 ohm between center and outer conductor.
-
Why should spare cable on 330104-01-08-50-01-05 remain uncut?Its 5.0 m electrical length is part of the calibrated system; shortening or splicing changes that chain.
-
What gap reference is used for radial vibration with 330104-01-08-50-01-05?The XL 8 mm reference is approximately 1.27 mm, corresponding to about -9 V under the specified calibration conditions.
-
Does the armor on 330104-01-08-50-01-05 replace correct connector isolation?No. Maintain the specified connector protection, electrical isolation and cable routing in addition to the armor.
-
Which target check matters before using nominal sensitivity with 330104-01-08-50-01-05?Confirm the actual target material and geometry against the AISI 4140 steel calibration assumptions before applying the 7.87 V/mm scale.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.