Technical specifications for 330104-00-14-05-02-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330104-00-14-05-02-00
-
Weight:0.16 kg
-
Tariff Code:8537101190
-
Sensing principle:Non-contact eddy current
-
Tip diameter:8 mm
-
Mounting thread:M10 x 1
-
Unthreaded section:0 mm
-
Case length:140 mm
-
Integral lead length:0.5 m
-
Lead construction:Armored standard coaxial cable
-
Connector:Miniature coaxial ClickLoc
-
Nominal system sensitivity:7.87 V/mm (200 mV/mil)
-
System linear range:2 mm (80 mils)
-
Standard calibration target:AISI 4140 steel
Information
- Bently Nevada 330104-00-14-05-02-00 places a short armored lead at the measurement location while the extension and conditioner establish the calibrated system.
Cable construction: Armored standard coaxial lead
Signal path: Matched probe, cable arrangement and Proximitor
The 0.5 m integral lead is combined with a compatible extension cable to establish the selected system electrical length. The probe cable length is not the total system length, and a mechanically matching extension does not establish electrical compatibility.
The conditioner output represents both static gap and dynamic target motion. Target material, mounting geometry and receiver configuration must remain within the intended measurement design. Armor protects the routed lead but does not replace proper support or connector protection.
330104-00-14-05-02-00 Original Technical Excerpt
The original technical excerpt supports 330104-00-14-05-02-00 configuration review. The separate Apter Power field guide organizes practical diagnostic checks. PDF · 5 pages.330104-00-14-05-02-00 Installation & Verification Guide
Apter Power engineering guide for the installed signal, power or communication path and controlled acceptance. PDF · 5 pages.
Application scope: The following uses describe supported engineering roles; they do not establish interchangeability with another model or remove application-specific validation.
Fluid-film bearing monitoring
Measure shaft motion with a compatible proximity channel.Static position measurement
Observe conductive target position within the matched-system range.Reference-pulse sensing
Support a properly configured Keyphasor or speed-reference arrangement.Probe replacement service
Match mounting geometry and electrical length to the installed chain.
Record the probe position, target material, sensing direction and monitor channel before removal. Compare the 140 mm case and 0 mm unthreaded portion with the actual bracket and working space. Preserve the original operating gap and the accepted channel scaling so a mechanical replacement does not silently alter the measurement baseline.
Trace the 0.5 m integral lead to its conditioner and identify the complete calibrated arrangement. This probe is used with the selected Proximitor electrical length through the compatible extension cable. Keep the machine protection in its approved maintenance state while the channel is interrupted, and label the coaxial connections before disconnecting them.
Inspect the probe tip, armored lead and connector for damage or contamination before installation. Route the armor with support that does not pull on the probe or coaxial connection. Secure the intended mounting position and protect the connector using the applicable installation method, then verify the gap again after locking the mechanical arrangement.
Use the matched chain and a suitable target to observe output at controlled gap positions within the intended operating region. Compare direction and sensitivity with the system requirements, allowing for target material and the receiving instrument. Keep any dynamic interpretation separate from a static electrical verification.
Restore the channel to the intended monitor and confirm scaling, normal gap indication and the configured protection response. Perform alarm or reference-pulse checks only under the approved controlled test method. Remove temporary stimuli and reconcile bypasses before returning the measurement to service, retaining the final probe and conditioner identities.
Probe configuration follows the metric ordering table; stated system performance requires a matched transducer chain and the specified target conditions.
Alternative Names
Technical notes
Configuration baseline: Keep the installed 3300 XL 8 mm system arrangement aligned with the complete 330104-00-14-05-02-00 reference and its assigned system role.
Acceptance boundary: Compare the electrical or communication response with the intended application outcome before releasing maintenance controls.
Technical reference: Bently Nevada 3300 XL 8 mm Proximity Transducer System, 141194 Rev. AN. Probe configuration follows the metric ordering table; stated system performance requires a matched transducer chain and the specified target conditions.
FAQ View All FAQ
-
Why does the half-metre lead of 330104-00-14-05-02-00 still require an electrical-length check?The lead is only one part of the calibrated transducer chain. Add the matching extension cable and compare the result with the Proximitor system length. Mechanical reach and calibrated electrical length are separate acceptance criteria.
-
How can bracket metal disturb the reading from 330104-00-14-05-02-00?Conductive material near the probe tip can influence the sensing field. Compare the mounted response with the approved target and mounting arrangement. A satisfactory bench check does not rule out interference introduced by the installed bracket.
-
What separates incorrect gap from a damaged 330104-00-14-05-02-00 probe?Check the complete matched chain and observe output while changing the target gap in a controlled fixture. A stable but offset response suggests a different issue from an open or intermittent connection. Do not diagnose from one installed voltage alone.
-
Why should 330104-00-14-05-02-00 cable armor not be used as a pulling handle?Mechanical loading can stress the cable termination and probe assembly. Support and route the lead without transmitting installation force through the sensing element. Recheck response after fastening and routing are complete.
-
Does 330104-00-14-05-02-00 measure shaft vibration without a Proximitor Sensor?No. The probe operates within a compatible transducer chain whose conditioner provides the measurement output. The probe alone is not a standalone voltage or current transmitter.
-
How should a shaft-material change be assessed for 330104-00-14-05-02-00?The standard calibration uses AISI 4140 steel. A different conductive target can change scale and linearity. Verify the complete system against the actual target material before relying on the nominal measurement sensitivity.
-
Why can 330104-00-14-05-02-00 give a good static gap but an unreliable vibration signal?Static position does not test bandwidth, cable intermittency or the receiving monitor settings. Verify the dynamic signal path and configured monitor scaling under the approved test procedure.
-
What confirms that 330104-00-14-05-02-00 stayed correctly gapped after locknut tightening?Recheck the output against the controlled gap after the final mounting operation. Mechanical movement during tightening can shift the sensing position. Record the final reading rather than relying on the pre-tightening setting.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.