Speak to a sourcing specialist
sales13@apterpower.com

3300/12-02-22-00

AC Power Supply
Ships by Saturday, November 7
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 3300/12-02-22-00 is a 3300/12 AC power supply for 3300 monitoring racks, configured for 190–250 Vac input and an internal-barrier Power Input Module.
  • Manufacturer part number
    3300/12-02-22-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    5cm × 30.5cm × 20.3cm
  • Country of Origin
    USA
Get a quick price for 3300/12-02-22-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 3300/12-02-22-00 marking, input supply and installed 3300 rack configuration.

  • 1

    Confirm the offer

    Review the offered module, Power Input Module, condition, included items and quoted dispatch date.

  • 2

    Arrange dispatch

    Confirm delivery details for 3300/12-02-22-00; tracking follows when shipment is arranged.

  • Match the complete marking

    Include 3300/12-02-22-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connector photos for 3300/12-02-22-00. Have your maintenance team compare the offered reference with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 3300/12-02-22-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/12-02-22-00
  • Weight:
    1.3 kg
  • Tariff Code:
    8537101190
  • Product type:
    AC Power Supply
  • Input voltage option:
    190–250 Vac (02)
  • Maximum input current:
    0.5 A
  • Power Input Module:
    Power Input Module with internal safety barriers (22)
  • Agency approval selection:
    No agency approval required (00)
  • Rack position:
    Position 1, leftmost slot beside the System Monitor
  • Rack supply capacity:
    Up to 12 monitors and associated transducers
  • Transducer supply selection:
    -24 Vdc (+0%/-2.5%) or -18 Vdc (+1%/-2%)
  • Output selection method:
    Jumper selection on the Power Supply PWA
  • Overload protection:
    Individual channels on monitor circuit boards
  • OK relay:
    Hermetically sealed SPDT; normally energized
  • OK relay location:
    Power Input Module behind the Power Supply
  • Relay operating life:
    10,000 cycles minimum at rated load
  • General operating temperature:
    0 to +65 °C; approval conditions may be more restrictive
  • Storage temperature:
    -40 to +85 °C
  • Relative humidity:
    95%, noncondensing
  • Input frequency:
    50–60 Hz, single phase
  • Power-up surge:
    26 A peak or 12 A rms for one cycle
  • Input noise filter:
    Standard line-noise filter
  • Ordered input fuse:
    0.75 A slow-blow; verify actual voltage configuration

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 3300/12-02-22-00 supports regulated rack and transducer power in a matched 3300 machinery monitoring system.
Product type: AC Power Supply
Ordered input: 190–250 Vac
Power input arrangement: Power Input Module with internal safety barriers
3300/12-02-22-00 selects 190–250 Vac input, 0.5 A maximum input current and power input module with internal safety barriers. The AC input is single-phase, 50–60 Hz, with a standard line-noise filter and a power-up surge of 26 A peak or 12 A rms for one cycle. Factory voltage selection can be changed only with the corresponding soldered-jumper and external-fuse configuration.

The supply occupies the leftmost rack position beside the System Monitor and powers up to 12 monitors plus their associated transducers. A jumper on the Power Supply PWA selects -24 Vdc (+0%/-2.5%) or -18 Vdc (+1%/-2%). Overload protection is provided for each individual channel on the monitor circuit boards; the chosen transducer supply must match the installed channels.

A normally energized, hermetically sealed SPDT OK relay is located on the Power Input Module behind the supply. Bently Nevada recommends an external annunciator because loss of primary power, monitor function or critical wiring can compromise machinery protection. Review the 3300 System Monitor, backplane and monitor firmware as a matched arrangement. The 3300/12 is not a direct power-supply replacement for an Original 3300 backplane. Approval option 00 does not specify an agency approval. An internal-barrier Power Input Module alone does not establish approval for the complete installation.
Controller platform reference: 3300 monitoring system. Match the supply, backplane and System Monitor.
Technical downloads for Bently Nevada 3300/12-02-22-00: a manufacturer technical excerpt and an Apter Power installation planning guide.
The technical reference preserves selected manufacturer pages. The installation guide is compiled by Apter Power for preparation and review; apply the original operating procedures and site controls during work.
Prepare 3300/12-02-22-00 against the installed rack configuration and applicable Bently Nevada instructions. Plan isolation and the resulting interruption of machinery monitoring before removal.
Confirm the input selection

Check 190–250 Vac, maximum input current 0.5 A, and the actual module configuration before connecting power. Input changes require the correct soldered jumper and external fuse.

Match the rack generation

Review the 3300 System Monitor, backplane and monitor firmware as a matched arrangement. The 3300/12 is not a direct power-supply replacement for an Original 3300 backplane.

Check the Power Input Module

Power Input Module with internal safety barriers is the ordered selection. Confirm the actual rear module and field wiring; do not interchange backplane generations without the applicable compatibility review.

Set the transducer supply

Verify the -18 Vdc / -24 Vdc jumper against the installed transducers and monitoring channels. A supply replacement must preserve the intended channel configuration.

Respect approval conditions

Approval option 00 does not specify an agency approval. An internal-barrier Power Input Module alone does not establish approval for the complete installation.

Plan loss of protection

Isolate rack power before removal and follow the site machinery-protection procedure. Restore and verify rack indications and external OK-relay annunciation before releasing the system.

Alternative Names

3300/12-02-22-00 Bently Nevada 3300/12-02-22-00 3300-12-02-22-00 3300/12 AC Power Supply

Technical notes

Input and configuration: 3300/12-02-22-00 selects 190–250 Vac input and power input module with internal safety barriers. Verify the actual input configuration and rack supply before service.

System compatibility: Review the 3300 System Monitor, backplane and monitor firmware as a matched arrangement. The 3300/12 is not a direct power-supply replacement for an Original 3300 backplane.

Approval conditions: Approval option 00 does not specify an agency approval. An internal-barrier Power Input Module alone does not establish approval for the complete installation.

Technical reference: Bently Nevada 3300/12 AC Power Supply, 141496-01 Rev. H; Bently Nevada 3300 System Compatibility Guide, 104003-01 Rev. G.

FAQ View All FAQ

  • What input does 3300/12-02-22-00 require?
    The ordered input range is 190–250 Vac, with maximum input current 0.5 A. It uses single-phase 50–60 Hz power. Check the soldered voltage selection and external fuse if the installed supply has been reconfigured.
  • Which Power Input Module is selected for 3300/12-02-22-00?
    Power Input Module with internal safety barriers is selected by option 22. Internal safety barriers do not independently establish approval for the entire installed system.
  • How many monitors can 3300/12-02-22-00 power?
    One power supply provides regulated power for up to 12 monitors and their associated transducers. It occupies rack position 1 at the left, beside the System Monitor.
  • Can 3300/12-02-22-00 provide different transducer supply voltages?
    The Power Supply PWA jumper selects -24 Vdc (+0%/-2.5%) or -18 Vdc (+1%/-2%). The ordered part number does not establish the current jumper position; verify the installed selection.
  • What is the purpose of the OK relay associated with 3300/12-02-22-00?
    The Power Input Module carries a hermetically sealed SPDT relay that is normally energized. Connect an external annunciator according to the rack wiring design so primary-power or monitoring faults are indicated.
  • What compatibility checks apply to 3300/12-02-22-00?
    Review the 3300 System Monitor, backplane and monitor firmware as a matched arrangement. The 3300/12 is not a direct power-supply replacement for an Original 3300 backplane.
  • What does approval option 00 mean on 3300/12-02-22-00?
    No agency approval required (00). Approval option 00 does not specify an agency approval. An internal-barrier Power Input Module alone does not establish approval for the complete installation.
  • How is the power output protected in 3300/12-02-22-00?
    Overload protection is provided for each individual channel on the monitor circuit boards. The AC input includes a standard line-noise filter; verify the correct external fuse for the actual input-voltage selection.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.