Technical specifications for 24701-28-05-00-070-04-02

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    24701-28-05-00-070-04-02
  • Estimated shipping dimensions:
    38x7.8x7.8cm
  • Weight:
    2.34 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Housing family:
    24701 stainless steel
  • Probe option:
    3300 XL 8 mm with approval option
  • Probe cable length:
    0.5 m / 20 in
  • Standoff:
    Not required
  • Probe penetration:
    7.0 in
  • Fittings option:
    04, one M25 fitting and one M25 plug
  • Mounting thread:
    3/4-14 NPT

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 24701-28-05-00-070-04-02 protects an externally mounted proximity probe while establishing its cable, penetration, fitting and thread arrangement.
  • Uses the stainless-steel 24701 externally mounted housing.
  • Includes the multiple-approval 3300 XL 8 mm probe option.
  • Sets probe penetration to 7.0 in without a standoff adapter.
  • Provides the selected M25 entry hardware and 3/4-14 NPT mounting thread.

The housing protects the sensing assembly but does not remove the need to support long reach, preserve target clearance and seal each cable entry correctly.

Important Notice: Confirm every segment of 24701-28-05-00-070-04-02 before preparing the mounting opening. Verify the complete proximity channel and record its final response before release.

Bently Nevada 24701-28-05-00-070-04-02 Manuals & Downloads
Bently Nevada 24701-28-05-00-070-04-02 Official Technical Reference Excerpt (PDF)Bently Nevada 24701-28-05-00-070-04-02 Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

External bearing housing
Protects a proximity probe installed through a machine bearing casing.
Shaft vibration sensing
Positions the 8 mm probe for non-contact shaft-relative vibration measurement.
Static position monitoring
Maintains a controlled probe reach for position or displacement channels.
Hazardous-area installation
Uses the selected approval and entry arrangement within the controlled installation design.
Before installing Bently Nevada 24701-28-05-00-070-04-02, confirm the documented system, interfaces and controlled configuration.
1
Confirm every segment of 24701-28-05-00-070-04-02 before preparing the mounting opening.
2
Verify the 3/4-14 NPT mounting thread and the 7.0 in penetration requirement.
3
Support the probe sleeve whenever the installed length can resonate.
4
Install the M25 fitting and plug with the approved seals so the enclosure remains protected.
5
Keep the probe connector and 0.5 m lead clean during assembly.
6
Check that the probe tip cannot contact the target across the full machine movement envelope.
7
Set gap only after housing, sleeve and lock hardware are fully secured.
8
Verify the complete proximity channel and record its final response before release.

Technical notes

Confirm every segment of 24701-28-05-00-070-04-02 before preparing the mounting opening. Verify the complete proximity channel and record its final response before release.

FAQ View All FAQ

  • Which probe is selected inside 24701-28-05-00-070-04-02?
    Option 28 specifies a 3300 XL 8 mm probe with the approval option.
  • Which lead length enters the 24701 housing under code 05 in 24701-28-05-00-070-04-02?
    Option 05 specifies 20 in, or 0.5 m.
  • Does 24701-28-05-00-070-04-02 use a standoff adapter?
    No. The standoff code is 00.
  • What is the penetration setting for 24701-28-05-00-070-04-02?
    Code 070 specifies 7.0 in.
  • Which cable-entry hardware belongs to 24701-28-05-00-070-04-02?
    Fittings option 04 supplies one M25 fitting and one M25 plug.
  • What machine thread is required for 24701-28-05-00-070-04-02?
    The final 02 option selects 3/4-14 NPT.
  • When should the sleeve of 24701-28-05-00-070-04-02 receive extra support?
    Add support when the installed reach can vibrate or resonate, especially for long penetration assemblies.
  • What must be proven after closing 24701-28-05-00-070-04-02?
    Verify enclosure sealing, probe gap, proportional output and the assigned monitor-channel response.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.